1. Introduction
This manual provides essential information for the safe and effective operation of your Walfront PEAKMETER PM2019A/PM2019S Flexible Clamp Meter. Please read this manual thoroughly before use and retain it for future reference. This device is a handheld professional detector designed to measure AC current, AC/DC voltage, resistance, and frequency.

Figure 1: User Manual Cover for Walfront PEAKMETER Flexible Clamp Meter.
2. Safety Information
To ensure safe operation, always adhere to the following safety precautions:
- Read and understand all instructions before using the meter.
- Observe all safety warnings and instructions marked on the meter.
- This meter is rated for CAT III 600V. Do not exceed the maximum input values specified for each function.
- Do not use the meter if it appears damaged or if the flexible inductor is compromised.
- Always disconnect the test leads from the circuit before changing functions.
- Exercise extreme caution when working with live circuits. High voltage can cause electric shock.
- Keep fingers behind the finger guards on the test leads during measurements.
- Replace batteries immediately when the low battery indicator appears to ensure accurate readings.
3. Product Overview
The Walfront PEAKMETER PM2019A/PM2019S Flexible Clamp Meter features a flexible inductor for measuring current in hard-to-reach areas. Key components are illustrated below:

Figure 2: Labeled components of the PM2019S Flexible Clamp Meter. Includes Flexible Inductor, Lighting, Open/Close points, LED Screen, Backlight button, Lighting button, Data Hold button, Switch button, and Port.
The meter is designed for ease of use with an LCD display, backlight, and a built-in flashlight for visibility in low-light conditions.

Figure 3: Key features of the meter include professional AC current and frequency measurement, 6000 counts display, Data Hold, Lighting, and Backlight.
4. Setup
4.1 Battery Installation
The PM2019A/PM2019S is powered by batteries. To install or replace batteries:
- Ensure the meter is powered off.
- Locate the battery compartment cover on the back of the meter.
- Use a screwdriver to open the battery compartment.
- Insert new batteries, observing correct polarity (+ and -). (Typically 2x AAA batteries, refer to the compartment for exact type).
- Securely close the battery compartment cover.
5. Operating Instructions
5.1 Powering On/Off
- To power on the meter, press the Switch Button (red circle button).
- The meter features an auto power-off function to conserve battery life. It will automatically shut down after a period of inactivity.
- To manually power off, press and hold the Switch Button.
5.2 Automatic Measurement Mode
The meter can automatically identify measured signals and display results. When powered on, it typically defaults to an auto-ranging mode.

Figure 4: The LCD screen displays 'AUTO' indicating automatic measurement mode and 'TRUE RMS' for accurate AC measurements.
5.3 AC Current Measurement
To measure AC current:
- Power on the meter.
- Press the 'Open' button to open the flexible inductor.
- Wrap the flexible inductor around a single conductor of the circuit where current needs to be measured. Ensure the inductor is fully closed around the conductor.
- Read the AC current value displayed on the LCD screen.

Figure 5: The flexible clamp meter in use, measuring current around a cable. The meter automatically identifies and displays the measured signal.
5.4 AC/DC Voltage, Resistance, and Frequency Measurement
For voltage, resistance, and frequency measurements, connect the test leads (not explicitly shown but implied by 'Port' and 'Multimeter' function) to the appropriate ports and the circuit under test. The meter will automatically detect the measurement type and display the result.
5.5 Data Hold Function
- Press the HOLD Button to freeze the current reading on the display.
- Press the HOLD Button again to release the data hold and resume live readings.
5.6 Backlight and Flashlight
- Press the Backlight Button (sun icon) to turn on the display backlight for improved visibility in dim conditions. Press again to turn off.
- Press the Lighting Button (light bulb icon) to activate the built-in flashlight. Press again to turn off.

Figure 6: The meter's LED display with backlight and flashlight active, demonstrating ease of operation and readability in various lighting conditions.
6. Maintenance
6.1 Cleaning
Wipe the meter with a dry, soft cloth. Do not use abrasives or solvents. Ensure the meter is powered off and disconnected from any circuits before cleaning.
6.2 Storage
When not in use for extended periods, remove the batteries to prevent leakage. Store the meter in a cool, dry place, away from direct sunlight and extreme temperatures.
7. Troubleshooting
If you encounter issues with your meter, refer to the following common problems and solutions:
- No Display: Check battery installation and ensure batteries are not depleted. Replace if necessary.
- Inaccurate Readings: Ensure the flexible inductor is properly closed around a single conductor for current measurements. Verify correct function selection for other measurements. Check battery level.
- Auto Power-Off: This is a normal function to save battery. Press the Switch Button to turn the meter back on.
8. Specifications
Technical specifications for the Walfront PEAKMETER PM2019A/PM2019S Flexible Clamp Meter:
| Parameter | PM2019A | PM2019S |
|---|---|---|
| AC Current | 30A/300A/3000A ± (3.0%+5) | 30A/300A/3000A ± (3.0%+5) |
| DC Voltage | 6V/60V/600V | 6V/60V/600V ± (1.0%+3) |
| AC Voltage | 6V/60V/600V | 6V/60V/600V ± (1.2%+3) |
| Resistance | 6kΩ/60kΩ/600kΩ/6MΩ | 6kΩ/60kΩ/600kΩ/6MΩ ± (1.0%+3) |
| Frequency | 40Hz-1kHz ± (1.0%+2), 20Hz-1kHz | 40Hz-1kHz ± (1.0%+2), 20Hz-1kHz |
| Display Count | 6000 counts | |
| Power Source | Battery Powered | |
| Dimensions (L x W x H) | 22.2 x 12 x 2.8 cm (8.7 x 4.7 x 1.1 inches) | |
| Item Weight | 420 g (0.93 lbs) | |
| Safety Rating | IEC 61010-1, CAT III 600V | |

Figure 7: Dimensions of the PM2019S Flexible Clamp Meter: 11.3cm/4.4" (head width), 7.5cm/3" (inductor connection length), 16.5cm/6.5" (handle length), 2.5cm/1" (handle base width).
9. Warranty and Support
For warranty information or technical support, please refer to the product packaging or contact your retailer. Keep your purchase receipt as proof of purchase.