Introduction
This manual provides comprehensive instructions for the installation, operation, and maintenance of the Hukcus MYPIN HH4-4RN Digital Timer Counter. Please read this manual thoroughly before using the device to ensure safe and efficient operation.

Figure 1: Front view of the Hukcus MYPIN HH4-4RN Digital Timer Counter, showing the LED display and control buttons.
Package Contents
Verify that all items listed below are present in the package:
- 1 x Hukcus MYPIN HH4-4RN Digital Timer Counter
- 2 x Mounting Brackets
- 1 x User Manual

Figure 2: The Hukcus MYPIN HH4-4RN Digital Timer Counter, along with its mounting brackets and user manual.
Technical Specifications
| Parameter | Value |
|---|---|
| Model | HH4-4RN |
| Material | ABS Plastic |
| Dimensions (L x W x H) | 48 x 48 x 80 mm |
| Panel Cutout Size | 45 x 45 mm |
| Time Range | 0.01 seconds - 9999 hours |
| Time Delay Range | 0.01 seconds - 99.9 hours |
| Output Type | Relay Output (1 Alarm) |
| Accuracy | ±0.01% F.S. |
| Reset Time | <0.2 seconds |
| Power Supply | 90-265V AC/DC |

Figure 3: Dimensions of the Hukcus MYPIN HH4-4RN Digital Timer Counter, showing 4.8cm (1.9in) width and height, and 8.5cm (3.3in) depth.
Setup and Installation
Mounting
The HH4-4RN timer is designed for panel mounting. Ensure the panel cutout size is 45 x 45 mm. Insert the timer into the cutout and secure it using the provided mounting brackets from the rear of the panel.
Wiring
Before connecting any wires, ensure the power supply is disconnected to prevent electrical shock. Refer to the wiring diagram below for correct connections. The timer accepts a power supply of 90-265V AC/DC.

Figure 4: Rear view of the timer showing the terminal block and wiring diagram for power input and relay output (OUT1).
Connect the power supply to terminals 7 and 8. The relay output (OUT1) consists of terminals 1 (Normally Open - NO), 2 (Common - COM), and 3 (Normally Closed - NC). Connect your load to the appropriate relay terminals based on your application requirements.
Operating Instructions
Front Panel Overview

Figure 5: Detailed view of the front panel, showing the PV (Process Value) and SV (Set Value) displays, control buttons (SET, RST, Up, Down), and status indicators (OUT1, OUT2, H, M, S).
- PV Display: Shows the current accumulated time or countdown value.
- SV Display: Shows the set alarm value or target time.
- SET Button: Used to enter programming mode and confirm settings.
- RST Button: Resets the timer. Also functions as a start/pause control.
- Up/Down Buttons: Used to adjust numerical values during setting.
- H/M/S Indicators: Indicate the currently selected time unit (Hours, Minutes, Seconds).
Basic Operation
- Power On: Connect the timer to a 90-265V AC/DC power supply. The display will illuminate.
- Start/Pause: Press the RST button to start or pause the timing process.
- Reset: To reset the timer to its initial state, press and hold the RST button for a few seconds until the display clears or resets.
Setting Time and Alarm Values
- Press the SET button to enter the setting mode. The SV display will start flashing.
- Use the Up and Down buttons to adjust the desired time or alarm value.
- Press SET again to confirm the value and move to the next setting parameter (if applicable).
- Continue pressing SET until all parameters are configured and the timer returns to normal operation mode.
Adjusting Time Units (H/M/S)
The time unit (Hours, Minutes, or Seconds) can be adjusted. Refer to the detailed programming section in the included paper manual for specific steps on how to change the time unit setting, as this typically involves a sequence of button presses in setting mode.
Maintenance
Cleaning
To clean the timer, wipe the surface with a soft, dry cloth. Do not use abrasive cleaners or solvents, as these may damage the plastic housing or display. Ensure the device is powered off before cleaning.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Timer does not power on. | No power supply or incorrect wiring. | Check power connections (90-265V AC/DC) and ensure wiring matches the diagram. Verify power source is active. |
| Display is blank or erratic. | Power fluctuation or internal error. | Disconnect and reconnect power. If the issue persists, contact support. |
| Timer does not start/pause. | RST button not functioning or timer in programming mode. | Ensure the timer is in normal operating mode. Press the RST button firmly. |
| Relay output not activating. | Incorrect wiring, alarm value not met, or faulty relay. | Verify relay wiring. Check if the set alarm condition has been met. Test the relay with a multimeter if possible. |
Warranty and Support
For warranty information or technical support, please refer to the documentation provided with your purchase or contact the retailer where the product was acquired. Specific warranty terms may vary by region and seller.