Olimpia Splendid 01914
Olimpia Splendid Dolceclima Compact 9 P Mobile Air Conditioner
Model: 01914
1. Introduction
The Olimpia Splendid Dolceclima Compact 9 P is a portable air conditioning unit designed to provide efficient cooling and dehumidification for your indoor spaces. Its compact size and mobility make it ideal for various room configurations. This manual provides essential information for safe operation, setup, maintenance, and troubleshooting.
2. Safety Information
Please read all safety warnings and instructions carefully before using this appliance to prevent injury or damage. Keep this manual for future reference.
- Electrical Safety: Ensure the power supply matches the unit's requirements (220V). Do not use extension cords or adapters. Always unplug the unit before cleaning or maintenance.
- Refrigerant: This unit uses R290 refrigerant, which is flammable. Do not puncture the refrigerant circuit. Only qualified personnel should service the unit.
- Placement: Place the unit on a flat, stable surface. Maintain adequate clearance around the unit for proper airflow. Do not block air inlets or outlets.
- Children and Pets: Keep children and pets away from the unit during operation. This appliance is not intended for use by persons with reduced physical, sensory or mental capabilities unless supervised.
- Condensate: The unit features automatic condensate drainage. However, in very humid conditions, manual drainage may be required. Ensure the drainage hose is properly positioned if used.
3. Product Overview
Familiarize yourself with the components and controls of your Dolceclima Compact 9 P.
3.1 Main Components
- Main Air Conditioner Unit
- Exhaust Hose
- Window Kit / Window Adapter
- Multifunction Remote Control
- Drainage Hose (for continuous drainage, if applicable)
3.2 Control Panel and Display
The unit features an intuitive control panel with an LCD display for easy operation. All functions can also be controlled via the remote control.

Image: Front view of the Olimpia Splendid Dolceclima Compact 9 P, showing the control panel and air vents.
4. Setup
Follow these steps for the initial setup of your air conditioner.
4.1 Unit Placement
Place the unit on a firm, level surface near a window or opening where the exhaust hose can be vented. Ensure there is at least 30 cm (12 inches) of space around the unit for proper air circulation.

Image: The mobile air conditioner positioned in a room next to a large window, demonstrating suitable placement for exhaust.
4.2 Exhaust Hose Installation
- Attach one end of the exhaust hose to the air outlet on the back of the unit.
- Connect the other end of the exhaust hose to the window adapter.
- Open the window and place the window adapter in the opening, ensuring a tight seal to prevent hot air from re-entering the room. Use the provided window kit for best results.
- Keep the exhaust hose as short and straight as possible to maximize cooling efficiency. Avoid kinks or sharp bends.
4.3 Power Connection
Plug the power cord into a grounded electrical outlet. Ensure the outlet meets the unit's voltage requirements (220V).
5. Operating Instructions
Learn how to use the various functions of your air conditioner.
5.1 Power On/Off
Press the POWER button on the control panel or remote control to turn the unit on or off.
5.2 Mode Selection
Press the MODE button to cycle through the available operating modes:
- Cooling Mode: For cooling the room. Adjust the temperature using the +/- buttons.
- Fan Mode: Circulates air without cooling. Adjust fan speed using the FAN SPEED button.
- Dehumidification Mode: Reduces humidity in the room. The unit will automatically drain condensate.
- Auto Mode: The unit automatically selects the operating mode based on the ambient temperature.
5.3 Temperature Adjustment
In Cooling Mode, use the +/- buttons to set your desired temperature. The temperature range is typically between 17°C and 30°C (62°F and 86°F).
5.4 Fan Speed
Press the FAN SPEED button to select between low, medium, or high fan speeds. In Auto Mode, the fan speed is adjusted automatically.
5.5 Timer Function
The 12-hour timer allows you to set a specific time for the unit to turn on or off. Refer to the remote control instructions for detailed timer setup.
5.6 Special Modes (Sleep/Turbo)
- Sleep Mode: Optimizes cooling for comfortable sleep by gradually increasing the set temperature and reducing fan speed.
- Turbo Mode: Provides maximum cooling power for rapid temperature reduction.
6. Maintenance
Regular maintenance ensures optimal performance and longevity of your air conditioner.
6.1 Filter Cleaning
The air filters should be cleaned every two weeks or more frequently depending on usage and air quality. Dirty filters can reduce cooling efficiency and airflow.
- Turn off and unplug the unit.
- Locate and remove the air filters (usually at the back or side of the unit).
- Wash the filters with lukewarm water and a mild detergent. Rinse thoroughly.
- Allow the filters to air dry completely before reinserting them into the unit.
6.2 Condensate Drainage
The Dolceclima Compact 9 P features automatic condensate drainage, meaning most water evaporates through the exhaust hose. However, in high humidity environments, the internal tank may accumulate water. If the unit stops operating and displays a