YARONGTECH ultrac50-10

YARONGTECH MIFARE Ultralight C Key Fob User Manual

Model: ultrac50-10

Brand: YARONGTECH

1. Product Overview

The YARONGTECH MIFARE Ultralight C Key Fob is a contactless identification device operating at 13.56MHz. These key fobs are designed for various access control and ticketing applications, featuring a durable ABS material construction and a convenient metal ring for attachment to keychains. Each pack contains 10 blue key fobs with a 50 pF capacitance.

MIFARE and MIFARE Ultralight C are registered trademarks of NXP B.V. and are used under license.

Two blue MIFARE Ultralight C key fobs with metal rings

Image 1.1: Two blue YARONGTECH MIFARE Ultralight C key fobs, each equipped with a metal ring for easy attachment. These fobs are designed for contactless identification and access control systems.

Key Features:

  • 3DES Authentication: Provides enhanced security for data transactions.
  • Anti-cloning Support: Each device includes a unique 7-byte serial number to prevent unauthorized duplication.
  • 32-bit User Programmable OTP Area: Allows for one-time programmable data storage.
  • Field Programmable Read-Only Locking: Functionality per page for the first 512-bit memory.
  • Read-Only Locking per Block: For memory areas above 512 bit.
  • Material: Durable ABS plastic with a metal ring.
  • Frequency: Operates at 13.56 MHz.

2. Setup

The MIFARE Ultralight C key fobs are designed to be programmed and integrated into existing or new access control and identification systems. Setup typically involves programming the unique identifier of each fob into your system's database.

Programming Steps (General):

  1. Prepare Your System: Ensure your RFID reader/writer and associated software are correctly installed and configured. Refer to your system's specific documentation for setup instructions.
  2. Access Programming Mode: Open the programming interface of your access control or RFID management software.
  3. Place Key Fob: Position the MIFARE Ultralight C key fob on or near the designated reading area of your RFID reader/writer.
  4. Read Fob ID: The software should detect and display the unique serial number (UID) of the key fob.
  5. Assign Permissions/Data: Input the UID into your system's database and assign the necessary access permissions or associate any required data with the fob.
  6. Save Configuration: Save the changes within your system.
  7. Test Fob: Test the programmed key fob with a compatible reader to ensure it functions as intended.

For detailed programming instructions, consult the manual of your specific RFID reader/writer and access control system.

3. Operating Instructions

Once the MIFARE Ultralight C key fob is successfully programmed into your system, its operation is straightforward.

Standard Use:

  1. Approach Reader: Hold the key fob within the reading range of a compatible 13.56MHz RFID reader. The exact distance may vary depending on the reader's power and antenna design.
  2. Wait for Confirmation: The reader will typically provide a visual (e.g., LED light change) or audible (e.g., beep) confirmation once the fob has been successfully read.
  3. Access Granted/Denied: Based on the programming, the system will grant or deny access, or perform the assigned function.

Ensure there are no metallic objects directly between the key fob and the reader, as this can interfere with the signal.

4. Maintenance

The MIFARE Ultralight C key fobs are designed for durability and require minimal maintenance.

  • Cleaning: Wipe the key fob with a soft, dry cloth if it becomes dirty. Avoid using harsh chemicals or abrasive cleaners.
  • Storage: Store key fobs in a cool, dry place away from direct sunlight and extreme temperatures.
  • Avoid Damage: While durable, avoid subjecting the key fobs to excessive force, bending, or impact, which could damage the internal chip.
  • Water Exposure: Although the ABS material offers some protection, prolonged exposure to water or submersion is not recommended.

5. Troubleshooting

If you encounter issues with your MIFARE Ultralight C key fobs, consider the following common troubleshooting steps:

  • Fob Not Reading:
    • Ensure the fob is placed correctly on the reader.
    • Check for metallic interference between the fob and the reader.
    • Verify the reader is powered on and functioning correctly.
    • Confirm the fob was successfully programmed into the system.
    • Test with another known working fob to isolate the issue to the fob or the reader/system.
  • Programming Failure:
    • Ensure your programming device/software is compatible with MIFARE Ultralight C chips.
    • Verify the key fob is positioned correctly on the programmer.
    • Check for any error messages from the programming software.
    • Ensure the fob is not already locked in a read-only state if you are attempting to write data.
  • Intermittent Reading:
    • This could indicate a weak signal from the reader or a slight misalignment. Try different angles or positions.
    • Ensure the fob is not damaged (e.g., cracked casing).

If problems persist, contact your system administrator or the product manufacturer for further assistance.

6. Specifications

AttributeDetail
ManufacturerYARONGTECH
Part Numberultrac50-10
Item Weight1.76 ounces
Package Dimensions2.99 x 2.09 x 0.94 inches
Item Model Numberultrac50-10
Style50 pF
Item Package Quantity10
Batteries Included?No
Batteries Required?No
ASINB07MGVCVCS
Date First AvailableJune 13, 2018

7. Warranty and Support

For information regarding product warranty, returns, or technical support, please refer to the purchase documentation or contact the seller/manufacturer directly. YARONGTECH products are typically covered by standard manufacturer warranties against defects in materials and workmanship.

Manufacturer Contact: Please visit the official YARONGTECH website or refer to the contact information provided at the point of purchase for support inquiries.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.