Allen-Bradley 1490N9

Allen-Bradley 1490N9 Series C 3/4 Inch Conduit Hub Instruction Manual

Model: 1490N9 Series C

1. Introduction

This manual provides essential information for the safe and proper installation, operation, and maintenance of the Allen-Bradley Bulletin 1490, 3/4 inch Conduit Hub, Model 1490-N9, Series C. This product is designed for use in industrial electrical applications to provide a secure connection for threaded conduit.

Please read this manual thoroughly before attempting any installation or service to ensure compliance with all safety guidelines and product specifications.

2. Safety Information

WARNING: Risk of Electric Shock or Fire Hazard.

3. Product Overview

The Allen-Bradley 1490N9 Series C Conduit Hub is a robust component designed to provide a secure and sealed connection point for 3/4 inch threaded conduit in various industrial environments. It is part of the Bulletin 1490 series of conduit fittings.

Allen-Bradley 1490N9 Conduit Hub product packaging

Figure 3.1: Allen-Bradley 1490N9 Conduit Hub product packaging.

This image displays the original product packaging for the Allen-Bradley Bulletin 1490, 3/4 inch Conduit Hub, Model 1490-N9, Series C. The label clearly indicates its UL Listed A206 and SP certified status, and specifies its intended use with threaded conduit only, and where specified by Allen-Bradley. It is rated for various environmental conditions, including Type 1, 3, 3R, 4, 12, and 13 applications.

Key features include:

4. Setup and Installation

Proper installation is critical for the safe and effective operation of the conduit hub. Always adhere to the following guidelines:

  1. Preparation: Ensure the installation area is clean, dry, and free from debris. Verify that the conduit to be used is 3/4 inch and threaded.
  2. Safety First: Before beginning installation, ensure all power to the associated electrical system is completely disconnected and properly locked out/tagged out to prevent accidental energization.
  3. Mounting: Securely fasten the conduit hub to the designated enclosure or junction box. Ensure the mounting surface is stable and capable of supporting the hub and connected conduit.
  4. Conduit Connection: Thread the 3/4 inch conduit into the hub opening. Tighten the connection firmly using appropriate tools to ensure a secure and sealed fit. Do not overtighten, as this may damage the threads.
  5. Sealing: If required by the application or local codes, apply appropriate thread sealant or sealing compound to ensure environmental integrity, especially in wet or dusty environments.
  6. Inspection: After installation, visually inspect all connections to ensure they are tight and secure. Verify that the conduit hub is properly aligned and that there are no exposed wires or loose components.

Consult relevant Allen-Bradley documentation and local electrical codes for specific installation requirements for your application.

5. Operating Instructions

The Allen-Bradley 1490N9 Conduit Hub is a passive component designed to provide a secure and protective pathway for electrical wiring. Once properly installed, it requires no active operation.

Its function is to maintain the integrity of the conduit system, protecting internal wiring from environmental factors and mechanical damage. Ensure that the conduit hub remains securely connected and free from physical damage to ensure continuous protection.

6. Maintenance

Regular inspection and minimal maintenance will ensure the longevity and continued performance of the conduit hub.

Always ensure power is disconnected before performing any maintenance that involves touching the hub or associated wiring.

7. Troubleshooting

As a passive component, the conduit hub typically does not "malfunction." Most issues relate to improper installation or external damage.

ProblemPossible CauseSolution
Loose conduit connectionInsufficient tightening during installation; vibration.Ensure power is off. Retighten the conduit connection firmly. Consider using thread-locking compound if vibration is a recurring issue.
Water or dust ingressImproper sealing; damaged hub or conduit.Ensure power is off. Inspect for cracks or damage. Reapply thread sealant if necessary. Replace the hub if damaged.
Physical damage to hubImpact; excessive force during installation.Ensure power is off. Replace the damaged conduit hub immediately to maintain system integrity and safety.

If you encounter issues not listed here, or if solutions do not resolve the problem, contact a qualified electrician or Allen-Bradley technical support.

8. Specifications

AttributeDetail
Product TypeConduit Hub
BrandAllen-Bradley
Model Number1490N9
SeriesC
Conduit Size3/4 Inch
CompatibilityThreaded Conduit Only
Environmental RatingsType 1, 3, 3R, 4, 12, 13
CertificationsUL Listed A206, SP®
Part Number (from packaging)10781180132855

9. Warranty and Support

For information regarding product warranty, technical support, or service, please contact your authorized Allen-Bradley distributor or visit the official Allen-Bradley website. Ensure you have the product model number (1490N9) and series (C) available when seeking support.

This product is designed for industrial use and should be installed and maintained by qualified professionals.

Related Documents - 1490N9

Preview PowerFlex 70 AC Drives, Frames A-E: Product Information and Specifications
Detailed product information, specifications, and selection guide for Allen-Bradley PowerFlex 70 AC Drives, covering frames A through E. Includes electrical ratings, input protection devices, wiring guidelines, and mounting clearances.
Preview CENTERLINE 2100 Motor Control Centers Selection Guide
This selection guide provides comprehensive information on the Allen-Bradley CENTERLINE 2100 Motor Control Centers, detailing features, options, selection processes, and technical specifications for industrial motor control applications.
Preview Allen-Bradley 1397 AC Line Disconnects Installation Guide for 400-600HP Drives
Comprehensive installation instructions for Allen-Bradley 1397-DS500 and 1397-DS600 AC Line Disconnects, designed for 400-600HP AC drives. This guide details kit contents, wiring connections, and safety procedures for proper setup.
Preview Allen-Bradley Regenerative DC Bus Supply Unit (RGU) Bulletin 2364F Troubleshooting Guide
This troubleshooting guide for the Allen-Bradley Regenerative DC Bus Supply Unit (RGU), Bulletin 2364F, provides essential information for diagnosing and resolving common failure conditions, component issues, and fault or warning indicators in industrial drive systems.
Preview IEC Busbar Mounting System Specifications - Allen-Bradley 141A & 141C
Comprehensive technical specifications for Allen-Bradley's 141C Crossboard® and 141A Classic IEC Busbar Mounting Systems. Includes product details, selection guides, dimensions, and industrial automation solutions from Rockwell Automation.
Preview Kinetix 5700 System Mounting Toolkit Installation Guide
This document provides installation instructions for the Kinetix 5700 System Mounting Toolkit, including how to use the drill-hole guide for various module widths.