Introduction
This manual provides essential instructions for the safe and efficient operation, maintenance, and troubleshooting of your Dyna-Glo WK24BK Indoor Kerosene Convection Heater. Please read all instructions carefully before assembly, installation, or use. Retain this manual for future reference.
The Dyna-Glo WK24BK is designed for supplemental indoor heating, providing up to 23,800 BTU/hour and capable of heating areas up to 1,000 square feet. It operates without electricity, making it suitable for emergency use.

Figure 1: Dyna-Glo WK24BK Indoor Kerosene Convection Heater, showing its overall design with a protective grille and control panel.
Important Safety Information
WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Read the installation, operating, and maintenance instructions thoroughly before installing or servicing this equipment.
- Carbon Monoxide Hazard: This heater produces carbon monoxide, which is an odorless, colorless gas that can cause death. Use a carbon monoxide detector in the vicinity of the heater. Ensure adequate ventilation.
- Fuel Type: Use only 1-K Kerosene. Never use gasoline, diesel fuel, paint thinners, or other fuels, as this can lead to fire or explosion.
- Ventilation: Always provide adequate ventilation. Do not use in airtight homes or unventilated spaces.
- Placement: Place the heater on a level, non-combustible surface. Maintain clear distances from combustible materials as specified in the full manual. This heater is for indoor residential use only.
- Tip-Over Protection: The heater is equipped with a tip-over shutoff feature that automatically turns off the unit if it is accidentally knocked over.
- Hot Surfaces: The top and grille of the heater become hot during operation. Avoid contact to prevent burns.
- Proposition 65 Warning: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

Figure 2: Use 1-K Kerosene only.

Figure 3: Designed for indoor residential use.

Figure 4: UL Certified for safety.
Setup and Fueling
1. Assembly
The Dyna-Glo WK24BK heater requires minimal assembly. Refer to the detailed diagrams in the full product manual for specific steps. Ensure all components are securely fastened before proceeding.
2. Fueling the Heater
- Ensure the heater is turned OFF and completely cool before fueling.
- Remove the fuel tank from the heater. The heater includes a siphon pump for easy and clean fueling.
- Fill the fuel tank with 1-K Kerosene only. The tank capacity is approximately 1.9 gallons. Avoid overfilling.
- Carefully replace the fuel tank into the heater, ensuring it is seated correctly.
- After initial fueling or if the wick has dried out, allow the wick to soak in kerosene for at least 60 minutes before attempting to ignite the heater. This ensures proper saturation and prevents damage to the wick.

Figure 5: Fuel gauge indicating run time and fuel level (F=Full, 1/2=Half, E=Empty).
Operating Instructions
1. Ignition
- Ensure the heater is on a level surface and the fuel tank is properly filled and seated.
- Open the flame viewing window (if applicable) to observe the wick.
- Press and hold the red "PUSH TO IGNITE" button (Figure 6) for a few seconds until the wick ignites. The heater features an automatic side ignition.
- Once ignited, release the button. Observe the flame through the viewing window (Figure 7) to ensure proper burning.

Figure 6: Close-up of the ignition button and wick height adjustment knob.

Figure 7: Flame viewing window to monitor wick performance.
2. Wick Height Adjustment
The wick height controls the flame size and heat output. Use the "WICK HEIGHT" knob (Figure 6) to adjust:
- Turn towards "RAISE" to increase flame height and heat output.
- Turn towards "LOWER" to decrease flame height and heat output.
Adjust the wick so the flame is stable and burns cleanly without excessive smoke or odor. An optimal flame is typically blue at the base with a yellow tip.
3. Shut-Off
To turn off the heater, use the one-touch shut-off lever (Figure 8). Push the lever down to quickly extinguish the flame. Ensure the flame is completely out before leaving the heater unattended.

Figure 8: Manual shutoff lever for quick and safe extinguishing of the flame.
Maintenance
Regular maintenance ensures optimal performance and extends the lifespan of your heater.
1. Wick Care
- Wick Cleaning: Periodically clean the wick to remove carbon buildup. This can be done by raising the wick to its highest position when the heater is cool, gently scraping off any carbon with a stiff brush, and then lowering it.
- Wick Replacement: Wicks typically last 2-3 years with proper maintenance. Replace the wick if it becomes frayed, damaged, or no longer produces a clean flame. Refer to the full manual for detailed wick replacement instructions.
2. General Cleaning
- Keep the exterior of the heater clean with a soft, damp cloth.
- Ensure the air intake and exhaust vents are free from dust and debris.
3. Storage
When storing the heater for extended periods, drain any remaining kerosene from the tank and allow the wick to dry completely. Store in a dry, dust-free environment.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Heater will not ignite. | No fuel, wick not saturated, igniter issue, wick too low. | Check fuel level, allow wick to soak (60 min), check igniter batteries, raise wick. |
| Excessive smoke or odor. | Improper fuel, wick too high, dirty wick, insufficient ventilation. | Ensure 1-K Kerosene is used, lower wick, clean wick, provide more ventilation. |
| Flame is weak or uneven. | Low fuel, dirty wick, wick needs replacement. | Refuel, clean wick, replace wick if necessary. |
| Heater shuts off unexpectedly. | Tip-over sensor activated, fuel tank empty. | Ensure heater is on a stable surface, check fuel level. |
For further troubleshooting or issues not listed, please contact customer support.
Specifications
- Model: WK24BK
- Brand: Dyna-Glo
- Heat Output: 23,800 BTU/hour
- Heating Coverage: Up to 1,000 sq. ft.
- Fuel Type: 1-K Kerosene
- Fuel Tank Capacity: Approximately 1.9 gallons
- Run Time: 8-12 hours per tank (approximate)
- Dimensions (D x W x H): 17.52" x 17.52" x 26.97"
- Special Features: Portable, Energy Efficient, Tip-Over Protection, Automatic Ignition
- Certifications: UL Listed

Figure 9: 360-degree convection heating for even distribution.

Figure 10: Heats up to 1000 sq. ft.
Warranty and Support
For warranty information, please refer to the warranty card included with your product or contact Dyna-Glo customer service directly. Keep your purchase receipt as proof of purchase.
Customer Support:
- Phone: 1-877-447-4768
- Manufacturer: GHP Group, Inc.
When contacting support, please have your model number (WK24BK) and purchase date available.