Rasmussen CS24-B-N

Rasmussen Custom Pan Vented Fireplace Burner Kit

Model: CS24-B-N (Natural Gas, 24x12-Inches)

1. Introduction

This manual provides essential instructions for the safe installation, operation, and maintenance of your Rasmussen Custom Pan Vented Fireplace Burner Kit, Model CS24-B-N. This kit is designed for use with natural gas in vented fireplace enclosures. Please read all instructions thoroughly before proceeding with installation or operation.

The Rasmussen Custom Pan Vented Fireplace Burner Kit is engineered for durability and provides a clean, classic pit fire appearance. It includes a custom pan burner with strap legs.

Rasmussen Custom Pan Vented Fireplace Burner Kit with strap legs

Image 1: Rasmussen Custom Pan Vented Fireplace Burner Kit. This image displays the burner pan with integrated strap legs, ready for installation in a fireplace.

2. Safety Information

WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information, consult a qualified installer, service agency, or the gas supplier.

  • This appliance is for use with natural gas only. Do not attempt to convert to propane or any other fuel type.
  • Installation and service must be performed by a qualified installer, service agency, or gas supplier.
  • Ensure adequate ventilation in the area where the burner is installed.
  • Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Keep children and pets away from the fireplace when the burner is in operation.
  • Proposition 65 Warning: This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

3. Components

The Rasmussen Custom Pan Vented Fireplace Burner Kit typically includes the following components:

  • Custom Pan Burner with Strap Legs
  • Gas Connector Kit (may vary by package)
  • Instruction Manual

Note: Additional decorative media (e.g., gas logs, lava rock, glass) are typically sold separately.

4. Setup and Installation

IMPORTANT: Installation of this gas appliance must be performed by a qualified professional in accordance with all local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54.

  1. Pre-Installation Check: Verify that the fireplace enclosure is clean, dry, and free of obstructions. Ensure the fireplace is vented and suitable for a natural gas appliance.
  2. Gas Supply: Ensure the gas supply line is properly sized and accessible within the fireplace. Turn off the main gas supply before beginning any work.
  3. Positioning the Burner: Place the burner pan centrally within the fireplace opening. The strap legs provide a freestanding installation. Ensure the burner is level and stable.
  4. Connecting Gas Line: Connect the gas supply line to the burner's inlet using appropriate gas connectors and sealant. All connections must be leak-tested using a non-corrosive leak detection solution.
  5. Placement of Media (Optional): If using decorative media such as gas logs or lava rock, arrange them according to their specific instructions, ensuring they do not obstruct the burner ports or pilot light (if applicable).
  6. Final Checks: After installation, turn on the main gas supply and perform a final leak test on all connections.

No specific product videos were provided by the seller for installation. Consult a professional for safe setup.

5. Operating Instructions

This burner kit is designed for match light operation. Always follow these steps carefully:

  1. Ensure Ventilation: Open the fireplace damper completely before lighting.
  2. Prepare to Light: Have a long match or lighter ready.
  3. Turn on Gas: Slowly open the gas valve to the burner. You should hear the gas flowing.
  4. Ignite: Immediately apply the flame from the match or lighter to the burner ports. The gas should ignite.
  5. Adjust Flame: Once ignited, adjust the gas valve to achieve the desired flame height.
  6. To Shut Down: Close the gas valve completely. Ensure the flames are extinguished. Close the damper only after the burner and fireplace have cooled down.

CAUTION: If the gas does not ignite within 5 seconds, turn off the gas valve, wait 5 minutes for gas to dissipate, and then repeat the lighting procedure. If ignition problems persist, consult a qualified technician.

6. Maintenance

Regular maintenance ensures safe and efficient operation of your burner kit.

  • Annual Inspection: Have the burner and gas connections inspected annually by a qualified service technician.
  • Cleaning: Periodically clean the burner ports to ensure even flame distribution. Use a soft brush to remove any dust or debris. Ensure the burner is cool before cleaning.
  • Check for Obstructions: Ensure that decorative media (if used) does not block burner ports or ventilation.
  • Ventilation: Regularly check that the fireplace damper and chimney are clear and unobstructed.

7. Troubleshooting

If you encounter issues with your burner kit, refer to the following common troubleshooting steps:

Problem Possible Cause Solution
No ignition or weak flame
  • Gas supply off or low pressure
  • Burner ports clogged
  • Damper closed
  • Check gas supply valve and pressure.
  • Clean burner ports.
  • Open damper fully.
Unusual odors
  • Gas leak
  • Incomplete combustion
  • Immediately turn off gas supply and ventilate area. Do not operate. Contact a qualified technician.
Sooting
  • Improper air/gas mixture
  • Obstruction of burner ports
  • Ensure proper media placement. Clean burner ports. Consult a technician for air/gas adjustment.

If problems persist after attempting these solutions, contact a qualified service technician.

8. Specifications

  • Brand: Rasmussen
  • Model Name: Custom Pan Vented Fireplace Burner Kit
  • Fuel Type: Natural Gas
  • Heat Output: 90,000 British Thermal Units (BTU)
  • Product Dimensions: 24 inches (W) x 12 inches (D) x 4.25 inches (H)
  • Material: Metal
  • Finish Type: Painted
  • Installation Type: Freestanding
  • Ventilation Type: Vented
  • Item Weight: 36 Pounds

9. Warranty and Support

This Rasmussen product comes with a Limited Warranty. For specific details regarding warranty coverage, terms, and conditions, please refer to the warranty documentation included with your purchase or contact Rasmussen customer support directly.

For technical assistance, replacement parts, or warranty claims, please contact Rasmussen customer service. Contact information can typically be found on the manufacturer's website or in the packaging materials.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.