This manual provides detailed instructions for the safe and efficient operation, installation, and maintenance of your VEVOR Double-Pipe Bottled Water Dispenser Pump System. Please read this manual thoroughly before use and retain it for future reference.
Product Features
- Dual-Tube System: Designed for two 5-gallon bottled water containers, extending usage cycles and reducing water change frequency.
- Powerful Performance: Operates at 40-60 PSI (2.8-4.1 bar) with a water outlet flow rate of 0.67 GPM (2.5 L/min) for consistent water supply.
- Wide Application: Suitable for providing clean water to faucets, refrigerators, ice makers, and coffee machines.
- Dual Switch Protection: Features a buoyancy switch for automatic shut-off when bottles are empty and a water pressure switch for automatic water supply upon faucet opening.
- Quiet Operation: Equipped with 4 shock-absorbing pads to minimize noise during use.
Safety Instructions
- Ensure the power supply matches the product's voltage (110 Volts).
- Always turn off the dispenser when changing water bottles.
- Do not operate the pump dry for extended periods.
- Keep the unit away from heat sources and direct sunlight.
- Use only food-grade tubing and connectors for water contact.
- Regularly inspect all connections for leaks.
Package Contents
- Bottled Water Dispensing System Unit
- 1/4" PE Tube (Length: 19.69 ft / 600 cm)
- Pre-installed Quick Connect (x1)
- Connector Nut (x1)
- Sealing Ring (x1)
- Silicone Foot Pads (x4)
Setup and Installation
Follow these steps for proper installation of your VEVOR Bottled Water Dispenser Pump System.
1. Unpacking and Placement
- Carefully remove all components from the packaging.
- Choose a suitable location for the pump unit and water bottles. Ensure there is enough space for two 5-gallon bottles and that the pump unit is mounted securely.


2. Connecting the Tubing
- Insert the long intake tubes into the 5-gallon water bottles. Ensure the tubes reach the bottom of the bottles.
- Connect the other end of the intake tubes to the designated inlet ports on the pump unit.
- Connect the 1/4" PE tube from the pump's outlet port to your appliance (e.g., refrigerator, coffee machine, faucet). Use the provided quick connect and sealing ring for a secure, leak-free connection.

3. Power Connection
- Plug the power cord into a standard 110V electrical outlet.
Operation
The VEVOR Bottled Water Dispenser Pump System is designed for automatic operation.
- Power On: Flip the power switch on the pump unit to the "ON" position. The pump will pressurize the system.
- Water Dispensing: When your connected appliance (e.g., refrigerator dispenser, coffee machine) demands water, the pump will automatically activate to supply water.
- Automatic Shut-off: The built-in buoyancy switch will detect when a water bottle is empty and automatically stop the pump to prevent dry running.
- Pressure Maintenance: The water pressure switch maintains consistent pressure in the line, ensuring a steady flow when needed.

Maintenance
Regular maintenance ensures optimal performance and longevity of your dispenser.
- Changing Water Bottles: Always turn off the pump unit before replacing empty water bottles. This prevents air from entering the system and ensures proper priming.
- Cleaning: Periodically clean the exterior of the pump unit with a damp cloth. Do not use abrasive cleaners.
- Tubing Inspection: Inspect the PE tubing for any kinks, cracks, or signs of wear. Replace if necessary.
- System Flush: If the system has been idle for an extended period, flush a small amount of water through it before use.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Pump not running | No power; Power switch off; Empty water bottle; Loose connection. | Check power cord and outlet; Turn on power switch; Replace water bottle; Secure all electrical and tubing connections. |
| Low water flow | Kinked tubing; Partially empty bottle; Air in the system; Clogged filter on intake tube. | Straighten tubing; Replace water bottle; Turn off and on to re-prime; Clean or replace intake filter. |
| Pump runs continuously | Leak in the system; Air leak in intake tube; Faulty pressure switch. | Check all connections for leaks; Ensure intake tubes are fully submerged and sealed; Contact customer support if switch is faulty. |
| Unusual noise | Vibration; Air in the system; Obstruction in pump. | Ensure pump is securely mounted; Check for air in lines; Inspect pump for foreign objects (unplug first). |
Specifications
| Feature | Detail |
|---|---|
| Brand | VEVOR |
| Model Number | Bottled Water Dispensing Pump System |
| Style | Double Inlet |
| Rated Power | 50W |
| Operating Pressure Range | 40-60 PSI (2.8-4.1 bar) |
| Water Outlet Flow Rate | > 0.67 GPM / > 2.5 L/min |
| Pump Head Flow Rate | > 1 GPM / > 3.8 L/min |
| Voltage | 110 Volts |
| Product Dimensions | 5.5"D x 2.8"W x 7.9"H (14 cm D x 7.1 cm W x 20.1 cm H) |
| Item Weight | 5.98 pounds (2.71 kg) |
| Material | Plastic |
| Installation Type | Stand-alone |
| Power Source | Corded Electric |

Warranty and Support