Taco 007-F5

Taco 007-F5 Cast Iron Circulator Pump Instruction Manual

Model: 007-F5

1. Introduction

This manual provides essential information for the safe and efficient installation, operation, and maintenance of the Taco 007-F5 Cast Iron Circulator pump. Please read these instructions thoroughly before installation or use to ensure proper function and to prevent potential hazards.

2. Safety Information

WARNING: Improper installation, operation, or maintenance can cause serious injury or property damage. Always adhere to local codes and regulations.

3. Product Overview

3.1 Product Description

The Taco 007-F5 is a cartridge-style, maintenance-free, wet-rotor, in-line, single-stage circulator pump. It is designed for quiet operation in various heating and recirculation systems, including hydronic heating, radiant heating, hydro-air fan coils, indirect water heaters, chilled fresh water, and domestic water recirculation systems. This model features cast iron construction and universal flanged connections. The unique replaceable cartridge contains all moving parts, allowing for easy servicing without replacing the entire unit.

3.2 Key Features

3.3 What's in the Box

3.4 Product Images

Taco 007-F5 Cast Iron Circulator Pump, front-side view
Front-side view of the Taco 007-F5 Cast Iron Circulator Pump. This image shows the main body of the pump, including the motor housing and the flanged connections for pipe integration.
Taco 007-F5 Circulator Pump with universal flange gaskets
Top-down view of the Taco 007-F5 Circulator Pump, showcasing the two universal pump flange gaskets included with the unit. The gaskets are essential for creating a watertight seal during installation.
Internal wiring of the Taco 007-F5 Circulator Pump
An open view of the internal wiring compartment of the Taco 007-F5 Circulator Pump. This image illustrates the electrical connections and components within the motor housing, including the capacitor and wire terminals.

4. Setup and Installation

Installation of the Taco 007-F5 circulator pump should be performed by a qualified professional in accordance with all applicable plumbing and electrical codes.

4.1 Pre-Installation Checks

4.2 Mounting the Pump

  1. The pump can be mounted in any position, provided the motor is horizontal.
  2. Install the pump in the return line of the heating system for optimal performance and longevity.
  3. Use the provided universal pump flange gaskets to ensure a leak-free connection to the piping. Secure flanges with appropriate bolts and nuts (not included).

4.3 Electrical Connections

  1. Turn off the main power supply to the circuit where the pump will be connected.
  2. Remove the motor housing cover to access the wiring terminal.
  3. Connect the power supply wires to the appropriate terminals inside the motor housing. Use the provided wire gland to secure the electrical cable and maintain strain relief.
  4. Ensure all connections are tight and secure. Replace the motor housing cover.

4.4 System Filling and Venting

  1. After installation, slowly fill the system with water, ensuring all air is purged.
  2. Open all manual air vents in the system.
  3. Once the system is full and pressurized, close the air vents.

5. Operating Instructions

The Taco 007-F5 circulator is designed for continuous operation in closed-loop hydronic systems. Once properly installed and wired, the pump will activate when power is supplied to its circuit, circulating fluid through the system.

5.1 Initial Start-Up

  1. Ensure the system is completely filled with water and all air has been vented.
  2. Restore power to the circulator pump.
  3. Listen for smooth operation. A noisy pump may indicate trapped air. If noise persists, re-vent the system.
  4. Check all connections for leaks.

5.2 Normal Operation

The circulator will operate silently and efficiently, moving fluid through your heating or recirculation system. No user intervention is typically required during normal operation.

6. Maintenance

The Taco 007-F5 circulator features a wet-rotor design, making it largely maintenance-free. The system fluid lubricates the motor and bearings.

6.1 Periodic Checks

6.2 Cartridge Replacement

In the event of pump failure or reduced performance, the unique replaceable cartridge assembly allows for easy servicing. Consult a qualified technician for cartridge replacement. This process typically involves:

  1. Shutting off power and isolating the pump.
  2. Draining the system or isolating the pump with shut-off valves.
  3. Removing the motor housing and old cartridge.
  4. Installing a new Taco 007-F5 replacement cartridge.
  5. Reassembling and re-pressurizing the system.

7. Troubleshooting

Before attempting any troubleshooting, ensure power is disconnected and the system is depressurized if working on plumbing components.

ProblemPossible CauseSolution
Pump does not runNo power; Blown fuse/tripped breaker; Motor seized; Faulty wiringCheck power supply; Reset breaker/replace fuse; Consult technician for motor inspection/replacement; Verify wiring connections.
Pump runs but no flow/poor flowAir in system; Closed valves; Clogged impeller; Incorrect rotation (unlikely for wet rotor)Vent system thoroughly; Open all isolation valves; Inspect/clean impeller (requires professional service); Ensure proper installation.
Excessive noise/vibrationAir in system; Worn bearings (cartridge); Cavitation; Improper mountingVent system; Replace cartridge assembly; Check system pressure/flow; Ensure pump is securely mounted.
Leaking at connectionsLoose flanges; Damaged gaskets; Improperly sealed threadsTighten flange bolts; Replace gaskets; Re-seal threaded connections with appropriate sealant.

8. Specifications

9. Warranty and Support

For specific warranty details, please refer to the documentation provided with your purchase or contact Taco, Inc. directly. Warranty coverage typically applies to defects in materials and workmanship under normal use and service.

For technical support, replacement parts, or service inquiries, please contact your authorized Taco distributor or visit the official Taco website. Always provide the model number (007-F5) when seeking support.

Related Documents - 007-F5

Preview Taco 0026e ECM High-Efficiency Circulator Instruction Sheet
Instruction sheet for the Taco 0026e ECM High-Efficiency Circulator, detailing its features, applications, installation, wiring, programming, and troubleshooting. This variable speed circulator offers significant energy savings and replaces older single and 3-speed models.
Preview Taco 1911ecm ECM High-Efficiency Circulator Instruction Sheet
Instruction sheet for the Taco 1911ecm ECM High-Efficiency Circulator, covering installation, operation, controller functions, specifications, and troubleshooting. Learn about its features, safety guidelines, and maintenance.
Preview Taco ACT/ACTF Air Separator Installation, Operation & Maintenance Manual
Comprehensive guide for installing, operating, and maintaining Taco ACT/ACTF Air Separators. Covers system types, maintenance procedures, safety warnings, and typical piping diagrams for hydronic heating and cooling systems.
Preview Taco Zone Controls Wiring Guide: Switching Relays & Zone Valve Controls
Comprehensive wiring guide from Taco detailing installation and configuration of zone control systems, including switching relays and zone valve controls for diverse HVAC applications.
Preview Taco Hot-LinkPlus-e: High-Efficiency Hot Water Recirculation System | Installation & Specs
Learn about the Taco Hot-LinkPlus-e system, an ECM high-efficiency hot water recirculation system. Features include instant hot water, water savings, SmartPlug control, and easy installation without a dedicated return line. Includes technical specifications and installation guide.
Preview Taco Zone Controls Wiring Guide: Installation and Wiring Diagrams for HVAC Systems
Comprehensive wiring guide for Taco Zone Controls, including switching relays, zone valve controls, boiler reset controls, and related HVAC components. Provides detailed diagrams and instructions for professional installation and system integration.