1. Product Overview

The Microtek Super Power Inverter Digital UPS Model 700 (12V) DG is a hybrid digital and sine wave UPS designed for home use. It integrates digital and sine wave technologies to provide reliable power backup, extended battery life, and efficient load handling. This UPS features an in-built bypass function for continuous power supply in case of UPS failure and incorporates advanced technology for smart operation.

Key Features:

  • Hybrid Technology: Combines digital and sine wave technologies for enhanced performance.
  • Low Watt Loss EI Core: Designed for energy efficiency and extended power backup.
  • Resettable Circuit Breaker: Provides safety for connected appliances.
  • Intelligent Pulse Technology: Ensures faster battery charging and longer battery life.
  • Auto Reset Function: Automatically resets during and after overload conditions.
  • Battery State Monitoring: Features a multi-stage battery charger for optimal battery health.
  • Mains Input Voltage Range Selection: Allows selection between standard (100V-300V) and narrow (180V-260V) voltage ranges.
  • Micro Controller Based Design: Intelligent control with LED display for status and fault indications.
  • CCCV Technology: Constant Current Constant Voltage charging with Auto Trickle Mode.
  • Smart Overload Sense and Short Circuit Protection: Enhances safety and reliability.
Microtek Super Power Inverter Digital UPS Model 700 (12V) DG front view

Figure 1: Front view of the Microtek Super Power Inverter Digital UPS.

2. Installation and Setup

Follow these steps for proper installation and setup of your UPS system.

2.1 Unpacking

  1. Carefully remove the UPS from its packaging.
  2. Inspect the unit for any signs of damage during transit. If damaged, do not proceed with installation and contact customer support.
  3. Ensure all accessories, including the instruction manual, are present.

2.2 Placement

  • Place the UPS in a well-ventilated area, away from direct sunlight, heat sources, and moisture.
  • Ensure there is adequate space around the unit for proper airflow.
  • Place the UPS on a flat, stable surface.

2.3 Battery Connection

The UPS is compatible with 1 x 12V battery with a capacity between 100 Ah and 200 Ah (Flat Plate, Tubular, SMF). Ensure the battery is purchased separately and is suitable for inverter use.

  1. Connect the red positive (+) cable from the UPS to the positive (+) terminal of the battery.
  2. Connect the black negative (-) cable from the UPS to the negative (-) terminal of the battery.
  3. Ensure all connections are tight and secure to prevent sparking or poor performance.

2.4 Power Connection

  1. Connect the UPS input power cord to a grounded wall outlet.
  2. Connect your appliances (lights, fans, TV, etc.) to the output sockets of the UPS. Do not overload the UPS beyond its rated capacity.

2.5 Initial Power On

  1. After connecting the battery and mains power, switch on the UPS using the main power button.
  2. Observe the display indicators for initial status. The UPS should indicate 'Mains On' and begin charging the battery if it's not fully charged.

3. Operation

Understanding the control panel and indicators is crucial for effective operation.

3.1 Control Panel and Display Indicators

The UPS features an LED display that provides real-time status and fault conditions.

Microtek UPS Display Indicators: Fault, Mains On, UPS On, Charging, Overload, Battery Low

Figure 2: Microtek UPS Display Indicators.

Table 1: Display Indicator Meanings
IndicatorDescription
Fault IndicationIndicates an internal fault or malfunction within the UPS.
Mains OnIndicates that the UPS is receiving power from the main electricity supply.
UPS OnIndicates that the UPS is actively providing power to connected appliances, either from mains or battery.
ChargingIndicates that the UPS is charging the connected battery.
OverloadIndicates that the connected load exceeds the UPS's capacity. Reduce the load immediately.
Battery LowIndicates that the battery charge level is low and requires recharging. The UPS will switch off soon.

3.2 Voltage Range Selection

The UPS features a slide selection switch for mains input voltage range. This allows optimization for different grid conditions.

  • Standard Voltage Range: 100 V ~ 300 V (Suitable for areas with wide voltage fluctuations).
  • Narrow Voltage Range: 180 V ~ 260 V (Suitable for areas with stable voltage supply).

Select the appropriate range based on your local power supply conditions.

3.3 Load Management Guidelines

To ensure optimal performance and backup time, manage the load connected to your UPS effectively. The UPS has a VA Rating of 600VA/510W and a Max. Peak Load of 760W.

Microtek Inverter Buying Guide for load capacity and backup time

Figure 3: General Load Management Guidelines for Inverters.

Refer to the general guidelines above to estimate backup times based on connected appliances and battery capacity. Avoid connecting heavy-duty appliances like air conditioners, geysers, or high-wattage motors directly to the UPS unless specifically rated for such loads.

4. Maintenance

Regular maintenance ensures the longevity and efficient operation of your UPS.

4.1 Battery Care

  • Regular Charging: Ensure the battery is regularly charged, even during periods of no power cuts, to maintain its health.
  • Water Level Check (for Tubular/Flat Plate Batteries): For non-SMF batteries, periodically check the electrolyte level and top up with distilled water if necessary.
  • Terminal Cleaning: Keep battery terminals clean and free from corrosion. Apply petroleum jelly to prevent corrosion.
  • Avoid Deep Discharge: While the UPS has low battery protection, try to avoid frequent deep discharges to prolong battery life.

4.2 Cleaning

  • Periodically clean the exterior of the UPS with a soft, dry cloth.
  • Ensure ventilation openings are free from dust and obstructions. Do not use liquid cleaners or solvents.

4.3 Storage

If storing the UPS for an extended period:

  • Ensure the battery is fully charged before storage.
  • Store the unit in a cool, dry place.
  • Recharge the battery every 3-6 months to prevent deep discharge and maintain battery health.

5. Troubleshooting

This section provides solutions to common issues you might encounter with your UPS.

Table 2: Common Troubleshooting Scenarios
ProblemPossible CauseSolution
UPS not turning onNo mains power; Battery not connected or discharged; Power switch off.Check mains power supply; Ensure battery connections are secure and charged; Turn on the UPS power switch.
Overload indicator onToo many appliances connected; Appliance drawing excessive power.Reduce the number of connected appliances; Disconnect high-power devices. The UPS has an auto-reset function.
Battery Low indicator onBattery discharged; Prolonged power cut.Allow the battery to recharge when mains power is available; Reduce load to extend remaining backup time.
UPS not providing backupBattery discharged or faulty; UPS in bypass mode.Check battery charge and health; Ensure UPS is not in bypass mode (if applicable, check manual for specific bypass switch location).
Fault indicator onInternal malfunction.Turn off the UPS, disconnect from mains and battery, wait a few minutes, then reconnect and restart. If the fault persists, contact customer support.

6. Technical Specifications

Detailed technical specifications for the Microtek Super Power Inverter Digital UPS Model 700 (12V) DG.

Microtek Super Power Inverter Specifications: 12 Volt, 700 VA, 36 Months Warranty, 340x382x198 MM Dimensions, 80-250 Ah Battery Capacity

Figure 4: Key Specifications of the Microtek Super Power Inverter.

Table 3: Detailed Product Specifications
FeatureSpecification
BrandMICROTEK
Model NameSUPER POWER UPS 700 12V DG
Model NumberMicr-Invert-001
Recommended UsesCompatible with Lithium-Ion Battery & Lead Acid Battery
Power SourceBattery Powered
Wattage510 Watts
Battery Compatibility1 x (12V) battery, 100 Ah - 200 Ah (Flat Plate, Tubular, SMF)
Voltage230 Volts (Output)
Input Voltage RangeStandard: 100 V ~ 300 V; Narrow: 180 V ~ 260 V
Output Power700 Watts
Standby Power Shutoff>84%
Peak Output Power230 Watts
Inverter Capacity (VA)600 VA
Electrical Output WaveformSquare Wave
Frequency50 Hz
Item Dimensions (L x W x H)38L x 34W x 19H Centimeters
Item Weight6900 Grams
ColorGrey
Box ContentsInverter
Country of OriginIndia

7. Warranty Information

The Microtek Super Power Inverter Digital UPS Model 700 (12V) DG comes with a manufacturer's warranty.

  • Warranty Period: 2 years warranty provided by the manufacturer from the date of purchase.
  • For warranty registration, contact Microtek at the time of purchase.

8. Support and Contact Information

For any assistance, technical support, or service requests, please contact Microtek customer support.

Microtek Support Services: Installation, Onsite Service, Paperless Warranty, On-call Support

Figure 5: Microtek Support Services.

  • Manufacturer: Microtek International Pvt. Ltd.
  • Address: H-57, Udyog Nagar, Rohtak Road, India
  • Contact Number: +91-7283838383
  • Email: cc@microtek.in
  • On-call Support: Available from 8 AM to 8 PM.
  • Installation: Installation services are available across India on demand. Note that accessories (wires, lugs, plugs, sockets, flexible pipe, clips, MCBs, earthing, and battery stand) are not included and must be provided by the customer if required.
  • Onsite Service: Available across India.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.