FORENSICS DETECTORS FD FD-90A-CO-PUMP

FORENSICS DETECTORS FD-90A-CO-PUMP Carbon Monoxide Detector with Pump Instruction Manual

Model: FD-90A-CO-PUMP | Brand: FORENSICS DETECTORS FD

1. Introduction and Overview

The FORENSICS DETECTORS FD-90A-CO-PUMP is a professional-grade Carbon Monoxide (CO) gas detector featuring an integrated pump for precise sampling. This device is designed for accurate and reliable detection of CO in various environments, offering a measurement range of 0-1000 ppm with 1 ppm resolution. It is USA NIST calibrated, ensuring high accuracy and comes with a calibration certificate. Built for durability, it is shock-proof, water-resistant, dust-proof, and explosion-proof, making it suitable for demanding applications. The unit includes adjustable audio, visual, and vibration alarms to alert users when preset CO levels are reached, along with alarm digital time stamp and logging capabilities. Its rechargeable USB battery provides extended operation, and it comes with all necessary accessories for immediate use.

FORENSICS DETECTORS FD-90A-CO-PUMP Carbon Monoxide Detector

Image: The FD-90A-CO-PUMP Carbon Monoxide Detector, a compact yellow and black device with a digital display.

2. What's Included

Upon unboxing your FORENSICS DETECTORS FD-90A-CO-PUMP, please ensure all components are present and in good condition:

  • FD-90A-CO-PUMP Carbon Monoxide Detector with integrated pump
  • Stainless steel probe
  • Silicone tubing for extended sampling
  • USB charging cable
  • Calibration and QA certificate (USA NIST Traceable)
  • User manual
  • Belt clip (pre-attached or included separately)
Unboxing contents of FD-90A-CO-PUMP

Image: All components of the FD-90A-CO-PUMP package laid out, including the detector, pump, probe, tubing, USB cable, and documentation.

3. Key Features

  • Accurate CO Detection: Measures 0-1000 ppm with 1 ppm resolution.
  • Integrated Pump: 0.5 LPM (500cc/min) pump for precise point sampling and enhanced response.
  • USA NIST Calibration: Factory calibrated to NIST traceable sources, ensuring high accuracy (sensor ≤±5% F.S., response time T<30s).
  • Robust Design: Shock-proof, water-resistant, dust-proof, and explosion-proof with a durable belt clip.
  • Multiple Alarms: Adjustable audio, visual (LED), and vibration alarms for critical alerts.
  • Data Logging: Features alarm digital time stamp and logging.
  • Rechargeable Battery: 1500mAh USB rechargeable Lithium Ion battery for long operational periods.
NIST Traceable Calibration Certificate

Image: A hand holding the FD-90A-CO-PUMP detector next to a NIST calibration certificate, highlighting its certified accuracy.

Video: CO Meter | USA NIST Traceable Calibrated

Video Description: This video demonstrates the FORENSICS DETECTORS CO Meter, emphasizing its USA NIST traceable calibration for accurate carbon monoxide detection.

4. Setup

4.1 Charging the Device

The FD-90A-CO-PUMP is equipped with a rechargeable Lithium Ion battery. To charge, connect the provided USB cable to the device's micro-USB port (located on the side) and plug the other end into any standard USB power source (e.g., computer, wall adapter). The charging indicator on the display will show the charging status.

4.2 Attaching the Belt Clip and Sling

The device comes with a durable stainless steel belt clip, allowing for convenient hands-free carrying. A ring at the top of the device also allows for attachment of a sling or lanyard for added security, especially when working at heights or in dynamic environments.

FD-90A-CO-PUMP with belt clip

Image: The FD-90A-CO-PUMP detector shown with its integrated belt clip, attached to a user's belt.

4.3 Initial Calibration Check

Your device comes factory calibrated to USA NIST traceable standards. It is recommended to perform a fresh air zero calibration before each use to ensure optimal accuracy. Refer to the 'Operating Instructions' section for details on performing a zero calibration.

5. Operating Instructions

5.1 Power On/Off

  • Power On: Press and hold the power button (usually the middle button) for a few seconds until the display illuminates. The device will perform a self-test.
  • Power Off: Press and hold the power button until the device powers down.

5.2 Display Information

The digital display shows real-time CO concentration in parts per million (ppm), temperature, and current time. It also indicates battery level and alarm status.

FD-90A-CO-PUMP digital display

Image: Close-up of the FD-90A-CO-PUMP's digital display showing CO concentration in ppm, temperature, and time.

5.3 Alarm Settings

The FD-90A-CO-PUMP features adjustable alarm thresholds for audio, visual (LED), and vibration alerts. These can be configured via the device's menu to suit specific safety requirements or local regulations. The device logs alarm events with a time stamp.

5.4 Using the Integrated Pump for Point Sampling

The integrated pump allows for active sampling, drawing air from a specific location through the stainless steel probe and silicone tubing. This is crucial for:

  • Confined Space Entry: Sampling air in areas like manholes, tanks, or ducts before entry.
  • Leak Detection: Pinpointing the source of CO leaks in HVAC systems, appliances, or exhaust vents.
  • Remote Sampling: Obtaining readings from hard-to-reach or hazardous locations without exposing the user or the main detector unit to the environment.

To use the pump, attach the silicone tubing to the barb at the end of the stainless steel probe, and then attach the probe to the device's inlet. Activate the pump via the device's menu or a dedicated button (refer to the detailed user manual for specific button functions). The display will show a load indicator for the pump.

FD-90A-CO-PUMP with sampling pump in use

Image: A user operating the FD-90A-CO-PUMP with the sampling probe extended, taking an air sample from a vent.

Video: Gas Sampling Pump (for Gas Detectors)

Video Description: This video provides a detailed explanation and demonstration of how to use a gas sampling pump with a gas detector, including attaching tubing and understanding its function for confined spaces.

Video: Do I Need a Gas Pump with my Gas Detector?

Video Description: This video explains the scenarios where an external gas sampling pump is necessary versus when a diffusive gas detector is sufficient, detailing the advantages of each setup.

6. Maintenance

6.1 Calibration

Regular calibration is essential for maintaining the accuracy and reliability of your CO detector. The FD-90A-CO-PUMP supports both zero and span calibration options. It is recommended to perform a fresh air zero calibration daily or before each use. Full span calibration with certified calibration gas should be performed periodically (e.g., every 6-12 months) or as required by your industry standards. Refer to the detailed user manual for step-by-step calibration procedures.

6.2 Cleaning and Storage

Keep the device clean and free from dust and debris. Use a soft, damp cloth for cleaning the exterior. Do not use harsh chemicals or abrasive cleaners. Store the device in a cool, dry place away from direct sunlight and extreme temperatures when not in use.

7. Troubleshooting

If you encounter any issues with your FD-90A-CO-PUMP, please refer to the following general troubleshooting tips:

  • No Power: Ensure the battery is fully charged. Try charging the device for at least 2 hours.
  • Inaccurate Readings: Perform a fresh air zero calibration. If issues persist, a full span calibration may be required. Ensure the sensor inlet is not obstructed.
  • Pump Not Working: Check for kinks or blockages in the silicone tubing and probe. Ensure the pump is activated correctly via the device menu.
  • Alarm Malfunction: Verify alarm settings in the device menu. If the alarm does not sound or vibrate when expected, contact customer support.

For more detailed troubleshooting steps and error codes, please consult the comprehensive user manual provided with your device or visit the FORENSICS DETECTORS support website.

8. Specifications

FeatureSpecification
BrandFORENSICS DETECTORS FD
Model NumberFD-90A-CO-PUMP
Sensor TypeElectrochemical
Measurement Range0-1000 ppm (Carbon Monoxide)
Resolution1 ppm
Sensor Accuracy≤±5% F.S.
Response TimeT<30s
Pump Flow Rate0.5 LPM (500cc/min)
AlarmsAudible, Vibration, Visual (LED) - Adjustable
Battery Type1500mAh Lithium Ion (rechargeable via micro-USB)
Operating Humidity95% (non-condensing)
MaterialABS
Item Weight130 Grams (4.6 ounces)
Product Dimensions1.69 x 2.28 x 4.33 inches
Environmental ProtectionShock-proof, Water-resistant, Dust-proof, Explosion-proof

9. Warranty and Support

The FORENSICS DETECTORS FD-90A-CO-PUMP comes with a 1-year limited warranty. Each device undergoes 100% product testing and verification in the USA and arrives with a comprehensive calibration and QA certificate, ensuring 100% quality guaranteed.

For technical support, warranty claims, or any questions regarding your device, please refer to the contact information provided in your user manual or visit the official FORENSICS DETECTORS website.

Video: CO Meter NIST calibrated

Video Description: This video features Dr. Koz, Chief Engineer at Forensics Detectors, introducing the professional carbon monoxide detector, highlighting its NIST traceable calibration and suitability for various users including engineers, technicians, and homeowners.

Video: Carbon Monoxide Portable Meter (USA NIST Calibrated)

Video Description: Dr. Koz from Forensics Detectors demonstrates the features of the handheld carbon monoxide meter, including its belt clip, USB charging, strong packaging, and the included NIST traceable calibration certificate, emphasizing its accuracy and reliability.

Ask a question about this manual