EXTRAUP 600W
EXTRAUP 600W Macerator Sewerage Sump Pump User Manual
Model: 600W
Introduction
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your EXTRAUP 600W Macerator Sewerage Sump Pump. Please read this manual thoroughly before installation and use to ensure proper function and longevity of the product.

Image: The EXTRAUP 600W Macerator Sewerage Sump Pump, a white compact unit with various pipe connections and an electrical cord.
Safety Information
Always adhere to local plumbing and electrical codes during installation. Disconnect power before performing any maintenance or service. Do not operate the pump if it is damaged or if the power cord is frayed. This pump is designed for waste water disposal and should not be used for other liquids or hazardous materials.
Package Contents
- 1 x 600W Macerator Sewage Pump
- 1 x User Manual
- Necessary installation accessories (clamps, connectors, etc.)

Image: Diagram showing the pump dimensions in centimeters and a layout of all included accessories such as hose clamps, screws, inlet caps, and an elbow pipe.
Setup and Installation
The EXTRAUP 600W Macerator Pump is designed for flexible installation, allowing for new plumbing setups in various locations without extensive structural changes. It features three inlets for connecting a toilet, sink, and/or shower.
Key Components:

Image: A detailed view of the pump highlighting the Power Box, Vent Valve, Discharge Outlet, and the three Inlets.
- Power Box: Contains the electrical connections and motor.
- Vent Valve: Allows for proper ventilation of the tank. Can be connected to an outdoor vent pipe.
- Discharge Outlet: Connects to the main waste line.
- Inlets: Three available inlets for connecting various fixtures (toilet, sink, shower).
Internal Structure:

Image: An exploded view showing the internal stainless steel non-clog blades responsible for macerating waste.
The pump features stainless steel non-clog blades for efficient waste maceration, ensuring smooth operation and reducing the risk of blockages.
Ventilation:

Image: Close-up of the vent valve on the top cover of the pump, indicating airflow for proper ventilation.
The tank is vented through a carbon filter in the vent valve located in the top cover. If necessary, it can be connected to a vent pipe through the vent hole that is drilled on the cover of the vent valve to exhaust outdoors.
Installation Options:

Image: Example installation where the pump and pipes are visible behind the toilet.
Option 1: Pipes Showing - The pump can be installed with visible piping, suitable for quick setups or where concealing pipes is not a priority.

Image: Example installation where the pump and pipes are concealed behind a wall or enclosure.
Option 2: Pipes Behind Wall - For a more discreet installation, the pump and associated plumbing can be concealed behind a wall or custom enclosure.
The pump is capable of vertical pumping up to 30 feet and horizontal pumping up to 260 feet, offering significant flexibility for placement within your home or facility.
Operating Instructions
The EXTRAUP 600W Macerator Pump operates automatically. When waste water enters the unit from connected fixtures (toilet, sink, shower), the pump's internal mechanism activates to macerate the solids and pump the liquid waste through the discharge pipe.

Image: The pump operating quietly, indicated by a sleeping baby in the background, with a noise level of 25-35dB.
The pump is designed for quiet operation, typically producing noise levels between 25-35dB, ensuring minimal disturbance in your living environment. It is fully automatic when activated by flushing or water entering from other connected inlets.
Maintenance
Regular inspection of the pump and its connections is recommended to ensure optimal performance. While the pump features stainless steel non-clog blades designed to minimize blockages, it is important to avoid flushing non-biodegradable items or excessive foreign objects into the system. For any specific cleaning or service, always disconnect the power supply to the unit. If you encounter persistent issues, consult a qualified plumbing professional.
Troubleshooting
If the pump is not operating as expected, consider the following:
- No Power: Check the power connection and ensure the outlet is functional.
- Pump Not Activating: Verify that water is entering the unit and that the internal float switch is not obstructed.
- Unusual Noise: This may indicate an obstruction. Disconnect power and carefully inspect the inlets and discharge for foreign objects.
- Reduced Pumping Performance: Check for partial blockages in the discharge pipe or issues with the macerator blades.
For issues that cannot be resolved with these basic steps, it is advisable to contact a qualified technician.
Specifications
| Feature | Specification |
|---|---|
| Brand | EXTRAUP |
| Model | 600W |
| Voltage | 110-120V/60Hz |
| Wattage | 600 watts |
| Maximum Flow Rate | 130 Liters Per Minute |
| Vertical Pumping Height | Up to 30 Feet |
| Horizontal Pumping Distance | Up to 260 Feet |
| Inlet Diameter | 83-100mm (main), 40-42mm (auxiliary) |
| Outlet Diameter | 32mm, 40mm |
| Material | Plastic |
| Product Dimensions | 16"L x 11"W x 11"H |
| Item Weight | 17.4 pounds (7.91 Kilograms) |

Image: A table summarizing the pump's performance specifications, including power, construction material, and vertical/horizontal pumping capabilities.
Warranty and Support
For information regarding product warranty, please refer to the documentation included with your purchase or contact EXTRAUP customer service directly. For technical support or service inquiries, please reach out to the manufacturer through their official channels.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.