RL LIVE YOUR LIGHT R62921501
Reality Leuchten Camillus R62921501 LED Ceiling Light User Manual
Model: R62921501
1. Introduction
Thank you for choosing the Reality Leuchten Camillus R62921501 LED Ceiling Light. This manual provides important information regarding the installation, operation, and maintenance of your new light fixture. Please read this manual thoroughly before installation and keep it for future reference.

Figure 1: Front view of the Camillus R62921501 LED Ceiling Light.
2. Safety Information
Please observe the following safety precautions to prevent injury or damage to the product:
- Always disconnect power at the main circuit breaker before installation, maintenance, or cleaning.
- Installation should be performed by a qualified electrician in accordance with local electrical codes.
- Do not modify the fixture in any way. Any modifications may void the warranty and pose a safety risk.
- Ensure the mounting surface can support the weight of the fixture.
- This product has an IP44 protection class, meaning it is protected against solid objects larger than 1mm and against splashing water from any direction. It is suitable for use in bathrooms (Zone 2 and 3, refer to local electrical regulations for bathroom zones).
- The integrated LED light source is not replaceable. Do not attempt to disassemble the LED module.
- This product contains a light source of energy efficiency class F.

Figure 2: IP Classification diagram illustrating suitable zones for IP-rated luminaires in bathrooms. The IP44 rating of this light makes it suitable for Zone 2 and 3 applications.
3. Package Contents
Carefully unpack the box and ensure all parts are present and undamaged. If any parts are missing or damaged, do not attempt to assemble or install the product. Contact your retailer for assistance.
- 1 x Camillus R62921501 LED Ceiling Light Fixture (with integrated LED reflector)
- 1 x Dimmer Switch (integrated functionality)
- Mounting Hardware (screws, wall plugs)
- User Manual (this document)
4. Installation
Before beginning installation, ensure the power supply is turned off at the circuit breaker. It is recommended to have two people for installation.
- Prepare the Mounting Surface: Choose a suitable location on the ceiling. Ensure there is adequate wiring available and that the surface is clean and dry.
- Mark Drilling Points: Hold the mounting bracket (if separate) or the fixture base against the ceiling at the desired installation point. Use a pencil to mark the positions for drilling holes.
- Drill Holes: Drill holes at the marked positions using an appropriate drill bit for your ceiling material. Insert wall plugs if necessary.
- Connect Wiring: Carefully connect the electrical wires from the ceiling to the fixture's terminal block. Ensure correct polarity (Live to Live, Neutral to Neutral, Earth to Earth). Secure all connections.
- Mount the Fixture: Align the fixture with the drilled holes and secure it to the ceiling using the provided screws. Ensure the fixture is firmly attached and flush with the ceiling.
- Restore Power: Once the fixture is securely mounted and all connections are checked, restore power at the main circuit breaker.

Figure 3: The Camillus LED Ceiling Light installed on a ceiling, showing its low-profile design.

Figure 4: Technical drawing showing the dimensions of the light fixture: 260mm diameter and 30mm height.

Figure 5: The light fixture with its 26 cm diameter clearly indicated.
5. Operating Instructions
The Camillus R62921501 LED Ceiling Light features an integrated switch dimmer function, allowing you to adjust the brightness using your standard wall switch.
5.1 Dimming Function
To cycle through the three brightness levels:
- Turn the light ON using your wall switch. The light will illuminate at its brightest setting (100%).
- To change the brightness, quickly turn the wall switch OFF and then ON again within 1-2 seconds. The light will switch to the next brightness level (e.g., 50%).
- Repeat the quick OFF/ON action to cycle to the third brightness level (e.g., 25%).
- Another quick OFF/ON action will return the light to its brightest setting (100%).
The light will remember the last selected brightness level if left off for more than 5 seconds.
6. Maintenance
The Camillus LED Ceiling Light requires minimal maintenance.
- Cleaning: Ensure the power is disconnected before cleaning. Wipe the fixture with a soft, dry or slightly damp cloth. Do not use abrasive cleaners, solvents, or harsh chemicals, as these can damage the finish or electrical components.
- LED Lifespan: The integrated LED has an average lifespan of 30,000 hours and does not require replacement.
7. Troubleshooting
If you encounter issues with your Camillus LED Ceiling Light, please refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Light does not turn on. | No power supply. Loose wiring connection. Faulty wall switch. | Check circuit breaker. Ensure all wiring connections are secure (power off first!). Test the wall switch with another device. |
| Light flickers or dims unexpectedly. | Unstable power supply. Loose wiring. Incompatible dimmer (if external). | Check household electrical system. Verify wiring connections. This fixture has an integrated dimmer; ensure no external dimmer is used unless specified as compatible. |
| Dimming function not working. | Incorrect operation. Too slow/fast switch toggling. | Ensure quick OFF/ON toggling within 1-2 seconds. Confirm you are using a standard ON/OFF wall switch, not an external dimmer. |
If the problem persists after trying these solutions, please contact customer support or a qualified electrician.
8. Specifications
| Feature | Detail |
|---|---|
| Brand | RL LIVE YOUR LIGHT |
| Model Number | R62921501 |
| Product Dimensions | 26 x 26 x 3 cm (Diameter: 26 cm) |
| Weight | 650 grams |
| Material | Acrylic |
| Color | White |
| Light Source Type | Integrated LED |
| Power Consumption | 15 Watts |
| Luminous Flux | 1350 lumens |
| Color Temperature | 3000K (Warm White) |
| Average Lifespan | 30,000 hours |
| Voltage | 230 Volts |
| IP Rating | IP44 |
| Special Features | Energy-efficient, Switch Dimmer (3 levels) |
| Installation Type | Ceiling Mount |
| Energy Efficiency Class | F |
| Country of Origin | China |
9. Warranty and Support
For warranty information and technical support, please refer to the terms and conditions provided by your retailer or contact Reality Leuchten customer service. Keep your proof of purchase for any warranty claims.
For further assistance, please visit the official RL LIVE YOUR LIGHT website or contact their support channels.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.