LSE Lighting LSE-4PIN-T5-17.5-25W-QTZ

LSE Lighting 4-Pin T5F Base UV Lamp (25W) Instruction Manual

Brand: LSE Lighting | Model: LSE-4PIN-T5-17.5-25W-QTZ

1. Introduction

This manual provides essential information for the safe and effective use of your LSE Lighting 4-Pin T5F Base UV Lamp. This ultraviolet replacement bulb is designed for use in various water UV systems requiring a 25W lamp. Please read this manual thoroughly before installation and operation.

LSE Lighting 4-Pin T5F Base UV Lamp

Image 1.1: The LSE Lighting 4-Pin T5F Base UV Lamp, showing its tubular design and 4-pin connector base.

Product Features:

  • Universal Compatibility: Designed to fit a wide range of water UV systems requiring a 25W 4-pin T5F base UV-C lamp.
  • Efficient Performance: Provides powerful ultraviolet light for water purification.
  • Premium T5 Quartz Construction: 17.5-inch length with single-ended 4-pin T5F base for easy and secure installation.
  • Extended Service Life: SuperLIFE rated for up to 12,000 hours of use, ensuring long-term reliability.
  • Quality Assurance: Manufactured in an EPA Registered Establishment (No. 96823-PA-1).
UV lamp used for water applications

Image 1.2: Illustration of the UV lamp's application in water purification systems.

2. Safety Information

Ultraviolet (UV-C) light can be harmful. Adhere to the following safety precautions:

  • Eye Protection: Never look directly at an illuminated UV lamp. UV-C radiation can cause severe eye damage.
  • Skin Protection: Avoid direct exposure of skin to UV-C light. UV-C radiation can cause skin irritation or burns.
  • Power Disconnection: Always disconnect power to the UV system before installing, removing, or servicing the lamp.
  • Handle with Care: UV lamps are made of glass and can break easily. Handle them by the ceramic ends, not the glass tube.
  • Disposal: Dispose of used lamps according to local regulations for hazardous waste, as they may contain mercury.
LSE Lighting UV lamp packaging with warning label

Image 2.1: Product packaging highlighting important safety warnings regarding UV light exposure.

3. Setup and Installation

Follow these general steps for installing or replacing your UV lamp. Always refer to your specific UV system's instruction manual for detailed, model-specific installation procedures.

  1. Disconnect Power: Ensure the UV system is completely disconnected from its power source.
  2. Wear Protective Gear: Put on appropriate eye protection (UV-blocking glasses) and gloves to avoid skin contact with the lamp and potential UV exposure.
  3. Remove Old Lamp (if applicable): Carefully remove the old UV lamp from the system. This usually involves unscrewing a cap, sliding out the quartz sleeve, and then detaching the lamp from its electrical connector.
  4. Clean Quartz Sleeve: If your system uses a quartz sleeve, gently clean it with a soft cloth and a mild cleaning solution (e.g., vinegar or citric acid) to remove any mineral deposits or film. Rinse thoroughly and dry completely before reinstallation.
  5. Install New Lamp: Hold the new LSE Lighting UV lamp by its ceramic ends. Align the 4 pins on the lamp base with the corresponding slots in the lamp connector within your UV system. Gently push the lamp into place until it is securely seated. Do not force it.
  6. Reassemble System: Carefully slide the quartz sleeve back into place (if removed) and secure any caps or retaining nuts according to your system's instructions. Ensure all seals are properly seated to prevent leaks.
  7. Reconnect Power: Once the lamp is securely installed and the system is reassembled, reconnect the power.
Close-up of the 4-pin base of the UV lamp

Image 3.1: Detail of the 4-pin base, illustrating the connection points for proper installation.

4. Operating Instructions

Once properly installed and the UV system is powered on, the LSE Lighting UV lamp will begin emitting UV-C light. The system is designed for continuous operation to maintain water quality.

  • Continuous Operation: For optimal water treatment, the UV lamp should operate continuously as part of your water purification system.
  • Indicator Lights: Many UV systems include indicator lights to confirm lamp operation. Consult your system's manual to understand its specific indicators.
  • Water Flow: Ensure water flows through the UV chamber at the recommended rate for effective treatment.

5. Maintenance

Regular maintenance ensures the continued effectiveness of your UV system and lamp.

  • Lamp Replacement: The LSE Lighting UV lamp has an effective life of up to 12,000 hours. For consistent performance, it is recommended to replace the lamp annually, even if it still appears to be working. The UV-C output diminishes over time, reducing its effectiveness.
  • Quartz Sleeve Cleaning: If your system uses a quartz sleeve, it should be cleaned periodically (e.g., every 3-6 months) to remove any buildup that can block UV light transmission. Refer to the "Setup and Installation" section for cleaning instructions.
  • System Inspection: Periodically inspect the UV system for any signs of leaks, damage, or wear.
Graph comparing LSE Lighting UV lamp life to other UV lamps, showing stable UV intensity

Image 5.1: Performance comparison illustrating the stable UV intensity maintenance and extended life of LSE Lighting UV lamps.

6. Troubleshooting

If you encounter issues with your UV lamp or system, consider the following:

  • Lamp Not Lighting:
    • Check power supply to the UV system.
    • Ensure the lamp is correctly seated in its connector.
    • Inspect the lamp for visible damage (e.g., broken glass, loose pins).
    • If the lamp is old, it may have reached the end of its life and requires replacement.
  • Reduced Water Treatment Effectiveness:
    • The lamp may be nearing the end of its effective life, even if it still glows. Replace annually.
    • The quartz sleeve may be dirty, blocking UV light. Clean the quartz sleeve as described in the Maintenance section.
    • Ensure water flow rates are within the system's recommended parameters.
  • Water Leaks:
    • Turn off the water supply and power immediately.
    • Check all O-rings and seals for proper seating and damage. Replace if necessary.
    • Ensure all caps and fittings are tightened correctly.

If troubleshooting steps do not resolve the issue, contact LSE Lighting customer support or a qualified technician.

7. Specifications

FeatureDetail
BrandLSE Lighting
Model NumberLSE-4PIN-T5-17.5-25W-QTZ
Wattage25 Watts
Lamp TypeUV-C Germicidal
Base Type4-Pin T5F
Length17.5 inches
MaterialQuartz Glass
Rated LifeUp to 12,000 hours (SuperLIFE)
ManufacturerLight Spectrum Enterprises, Inc
UPC843324104203

8. Warranty and Support

Warranty:

This LSE Lighting UV lamp comes with a 1-year warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use. It does not cover damage resulting from improper installation, misuse, accidents, or normal wear and tear (e.g., diminished UV output over time).

Customer Support:

For technical assistance, warranty claims, or further information, please contact LSE Lighting customer support. Refer to the product packaging or the LSE Lighting website for current contact details.

Video 8.1: An introduction to LSE Lighting, showcasing their commitment to UV light technology for air, surface, and water sterilization.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.