Yale DC135-----D9016
Tesa Assa Abloy DC135-D9016 Door Closer User Manual
Model: DC135-----D9016
Product Overview
The Tesa Assa Abloy DC135-D9016 is a high-quality door closer designed for efficient and controlled door operation. This model features a sliding guide and is suitable for doors up to 950 mm wide. It is certified according to European standards UNE-EN1154, with an EN3 force rating, making it ideal for medium-high traffic areas.
Key features include:
- Sliding guide door closer for doors up to 950 mm wide.
- EN3 force certified according to European standards UNE-EN1154.
- Three speed control valves for precise adjustment of closing speed, final stroke speed, and opening brake.
- Tested for durability up to 500,000 opening and closing cycles, suitable for medium-high traffic doors.
- Suitable for use in fire doors.
- Controlled opening and closing from 180 degrees.

Figure 1: The Tesa Assa Abloy DC135-D9016 Door Closer in white, showcasing its sleek design and sliding arm mechanism.
Setup and Installation
The DC135-D9016 door closer is designed for screw-in installation. Proper installation is crucial for optimal performance and safety. No batteries are required for the operation of this mechanical door closer.
Pre-Installation Considerations
- Ensure the door width does not exceed 950 mm.
- Verify the door material is suitable for screw-in installation.
- Gather necessary tools, including a drill, screwdriver, and measuring tape.
Mounting Instructions
Refer to the detailed dimension diagram for precise mounting hole placement. Accurate measurements are essential for correct alignment and function.

Figure 2: Detailed technical drawing showing the dimensions and mounting points for the door closer and its sliding guide. All measurements are in millimeters.
- Mark the drilling points on the door frame and door according to the provided diagram.
- Drill pilot holes as required for the mounting screws.
- Securely attach the main body of the door closer to the door frame.
- Attach the sliding guide to the door.
- Connect the sliding arm to the main body and the sliding guide.
- Ensure all screws are tightened securely, but do not overtighten.
Operating and Adjustment
The DC135-D9016 door closer allows for precise control over the door's movement, ensuring smooth and safe operation. It features three adjustable valves to fine-tune the closing cycle.
Adjustment Valves
- Closing Speed (VC): Controls the speed at which the door closes from its fully open position until approximately 15 degrees from the frame.
- Final Stroke Speed (GF): Controls the speed of the final few degrees of closing, ensuring the latch engages properly without slamming.
- Opening Brake (FA): Provides resistance when the door is opened beyond a certain point (e.g., 70 degrees), preventing it from swinging open too forcefully.
The door closer is designed to allow controlled opening up to 180 degrees, depending on installation and door type.

Figure 3: Diagram illustrating the adjustable phases of door closer operation: Closing Speed (VC), Final Stroke Speed (GF), Opening Brake (FA), and Hold-Open Position (PR).
Adjusting the Valves
To adjust the speed and brake functions, use a suitable tool (e.g., a flathead screwdriver) to turn the respective adjustment screws. Turn clockwise to decrease speed/increase resistance, and counter-clockwise to increase speed/decrease resistance. Make small adjustments and test the door's operation after each change.
Maintenance
The Tesa Assa Abloy DC135-D9016 door closer is engineered for high durability and minimal maintenance, having been tested for up to 500,000 opening and closing cycles.
- Regular Inspection: Periodically check all mounting screws to ensure they remain tight. Inspect the sliding guide and arm for any signs of wear or damage.
- Cleaning: Wipe down the exterior surfaces with a soft, damp cloth to remove dust and grime. Avoid abrasive cleaners or solvents.
- Lubrication: The internal mechanisms are factory-lubricated and generally do not require additional lubrication. If unusual noises or stiffness occur, consult a professional.
- Functionality Check: Regularly test the door's closing and opening behavior to ensure the speed and brake settings are still optimal. Readjust if necessary.
Troubleshooting
This section addresses common issues that may arise during the use of your door closer.
| Problem | Possible Cause | Solution |
|---|---|---|
| Door slams shut or closes too slowly. | Incorrect closing speed (VC) adjustment. | Adjust the closing speed valve. Turn clockwise to slow down, counter-clockwise to speed up. |
| Door does not latch properly or slams at the end. | Incorrect final stroke speed (GF) adjustment. | Adjust the final stroke speed valve. Ensure it provides enough force to latch without excessive speed. |
| Door opens too freely or with too much resistance. | Incorrect opening brake (FA) adjustment. | Adjust the opening brake valve. Increase resistance if the door swings too freely, decrease if it's too hard to open. |
| Difficulty in adjusting force/speed after installation. | Improper initial installation or damaged internal components. | Double-check all mounting points and ensure the unit is level. If issues persist, professional assistance may be required. Avoid forcing adjustments. |
| Unusual noises during operation. | Loose components or internal wear. | Inspect all visible parts for looseness. If the noise persists, contact customer support. |
Specifications
| Attribute | Detail |
|---|---|
| Model Number | DC135-----D9016 |
| Brand | Yale (Tesa Assa Abloy) |
| Color | White |
| Material | Metal |
| Installation Type | Screw-In |
| Product Dimensions | 22.05 x 4.92 x 2.36 inches (560 x 125 x 60 mm) |
| Item Weight | 5.28 pounds (2.4 Kilograms) |
| Recommended Uses | Controlling the opening and closing of medium-high traffic sliding doors, including fire doors. |
| Certification | EN3 certified according to European standards UNE-EN1154. Suitable for fire doors. |
| Durability | Tested up to 500,000 opening and closing cycles. |

Figure 4: Fire door compatibility symbol and CE certification label, indicating compliance with European standards.
Warranty and Support
For specific warranty information regarding your Tesa Assa Abloy DC135-D9016 Door Closer, please refer to the documentation provided at the time of purchase or visit the official Yale/Tesa Assa Abloy website.
If you require technical assistance, have questions about installation, operation, or troubleshooting beyond what is covered in this manual, please contact the manufacturer's customer support:
- Manufacturer: Tesa Assa Abloy (Brand: Yale)
- Website: www.yalehome.com (or relevant regional site)
- Contact Information: Refer to the manufacturer's website for the most current contact details, including phone numbers and email support.
When contacting support, please have your product model number (DC135-----D9016) and purchase date available.
Ask a question about this manual