Introduction
This manual provides essential information for the safe and effective use of your SigmasTek SP12-22 NB 12 Volt 22AH Sealed Lead Acid Battery. Please read these instructions carefully before installation, operation, or maintenance to ensure optimal performance and longevity of your battery.
Safety Information
WARNING: Improper handling of batteries can lead to serious injury or damage. Always follow safety guidelines.
- Wear appropriate personal protective equipment, including safety glasses and gloves, when handling batteries.
- Do not short-circuit the battery terminals. This can cause severe arcing, fire, or explosion.
- Keep the battery away from open flames, sparks, and heat sources.
- Do not disassemble, puncture, or incinerate the battery.
- Charge the battery in a well-ventilated area to prevent the accumulation of hydrogen gas.
- In case of contact with battery acid, flush the affected area with water immediately and seek medical attention.
- Ensure proper polarity when connecting the battery to avoid damage to the battery or connected equipment.
- Dispose of spent batteries according to local regulations. Do not discard with household waste.
Product Overview
The SigmasTek SP12-22 NB is a high-quality 12 Volt 22 Amp-hour (AH) Sealed Lead Acid (SLA) battery designed for various applications requiring reliable power. It features Absorbent Glass Mat (AGM) technology, providing a maintenance-free and spill-proof design.

This image displays the SigmasTek SP12-22 NB 12 Volt 22AH Sealed Lead Acid Battery. The battery features a rectangular white casing with a black top, showing two NB terminals. The label on the battery indicates 'Rechargeable Sealed Lead-Acid Battery (12V22AH NB)' and provides charging instructions for floating use (13.50-13.80V), cycle use (14.40-15.0V), and initial current (max 5.40A). Recycling symbols and a UL certification mark are also visible.
Key Features:
- Absorbent Glass Mat (AGM) Technology
- Maintenance-Free Design with Spill Proof Construction
- NB Terminal Type
- Factory Fresh Condition
Setup and Installation
Before installation, inspect the battery for any physical damage. Ensure the terminals are clean and free of corrosion.
- Preparation: Ensure the area where the battery will be installed is clean, dry, and well-ventilated.
- Terminal Connections: Connect the positive (+) terminal of the battery to the positive lead of your device or charging system. Connect the negative (-) terminal of the battery to the negative lead. Ensure connections are secure and tight to prevent arcing and power loss.
- Polarity Check: Double-check that the polarity is correct before applying power. Incorrect polarity can damage the battery and connected equipment.
- Securing the Battery: Place the battery in a stable position where it will not be subject to excessive vibration or movement.
Operating Instructions
This battery is designed for both floating and cyclic applications. Proper charging is crucial for battery life.
Charging Instructions:
Use a charger specifically designed for sealed lead-acid batteries. Refer to the charger's manual for detailed operation.
- Floating Use (Standby): For applications where the battery is continuously connected to a charger and used as a backup power source. The recommended voltage range is 13.50V - 13.80V.
- Cycle Use (Deep Cycle): For applications where the battery is regularly discharged and recharged. The recommended voltage range is 14.40V - 15.0V.
- Initial Current: The maximum initial charging current should not exceed 5.40A. Exceeding this limit can damage the battery.
Avoid overcharging or deep discharging the battery, as both can significantly reduce its lifespan.
Maintenance
The SigmasTek SP12-22 NB battery is maintenance-free, meaning it does not require water additions. However, regular checks can help ensure optimal performance.
- Keep Clean: Periodically clean the battery terminals and casing with a damp cloth to remove dust and dirt. Ensure terminals are free of corrosion.
- Check Connections: Verify that all terminal connections remain tight and secure.
- Storage: If storing the battery for an extended period, ensure it is fully charged and stored in a cool, dry place. Recharge the battery every 3-6 months to prevent self-discharge and maintain its capacity.
- Temperature: Operate and store the battery within recommended temperature ranges to prevent performance degradation.
Troubleshooting
If you encounter issues with your battery, consider the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Battery not holding a charge | Undercharging, overcharging, sulfation, or end of life. | Verify charger settings and voltage. Ensure proper charging cycles. If the battery is old, replacement may be necessary. |
| Battery not charging | Faulty charger, loose connections, or deeply discharged battery. | Check charger functionality and connections. Attempt a slow, low-current charge if deeply discharged. |
| Reduced capacity or runtime | Aging battery, improper charging, or operating in extreme temperatures. | Ensure correct charging parameters. Consider battery replacement if it's past its expected lifespan. |
| Overheating during charge | Overcharging, high charging current, or internal short circuit. | Immediately disconnect the charger. Verify charging voltage and current. If overheating persists, discontinue use and replace the battery. |
Specifications
- Model Number: SP12-22 NB
- Voltage: 12 Volts
- Capacity: 22 Amp Hours (AH)
- Battery Cell Composition: Sealed Lead Acid (SLA)
- Terminal Type: NB Terminal
- Product Dimensions: Approximately 7.13 x 3 x 6.59 inches
- Weight: Approximately 13.5 Pounds
- Technology: Absorbent Glass Mat (AGM)
- Design: Maintenance-Free, Spill Proof Construction
Warranty and Support
The SigmasTek SP12-22 NB battery comes with a 1 Year Warranty from the date of purchase. This warranty covers manufacturing defects under normal use and service.
For warranty claims, technical support, or further assistance, please contact SigmasTek customer service through their official channels. Keep your proof of purchase for warranty validation.