Fluke Networks DSX2-5000/GLD

Fluke Networks DSX2-5000/GLD Versiv 2 CableAnalyzer User Manual

Model: DSX2-5000/GLD

1. Introduction

This manual provides comprehensive instructions for the safe and effective use of the Fluke Networks DSX2-5000/GLD Versiv 2 CableAnalyzer. This device is designed for copper cable certification, ensuring network infrastructure meets industry standards. Please read this manual thoroughly before operating the device.

Fluke Networks DSX2-5000/GLD Versiv 2 CableAnalyzer kit including main unit, remote unit, adapters, cables, power supplies, and carrying case.

Figure 1: The Fluke Networks DSX2-5000/GLD Versiv 2 CableAnalyzer kit. This image displays the complete package, including the main Versiv 2 unit, a remote unit, various test adapters, patch cords, power adapters, and a black carrying case with the "FLUKE networks" logo. The components are laid out on a white background, showcasing the tools necessary for comprehensive cable certification.

2. Setup and Initial Configuration

2.1 Unpacking and Inspection

Carefully unpack all components and verify that all items listed in the packing list are present and undamaged. If any items are missing or damaged, contact Fluke Networks support immediately.

2.2 Charging the Battery

Before first use, fully charge the main unit and remote unit batteries. Connect the power adapters to the units and plug them into an AC outlet. The charging indicator will illuminate. A full charge typically takes several hours.

2.3 Powering On and Initial Setup

  1. Press and hold the power button on the main Versiv 2 unit until the display illuminates.
  2. Follow the on-screen prompts to configure language, date, time, and other initial settings.
  3. Ensure the latest firmware is installed. Connect the unit to a Wi-Fi network or a computer with internet access to check for updates.

2.4 Attaching Test Modules

The Versiv 2 platform supports various test modules. For copper certification, attach the DSX-5000 copper module to both the main and remote units. Ensure the modules click securely into place.

3. Operating Instructions

3.1 Basic Cable Certification

  1. Select Test: From the home screen, tap "TEST" and select the desired test limit (e.g., TIA Cat 6A, ISO Class EA).
  2. Connect Cables: Connect one end of the cable to be tested to the main unit's DSX-5000 module and the other end to the remote unit's DSX-5000 module using appropriate patch cords.
  3. Run Test: Tap the "TEST" button on the screen. The unit will perform a series of measurements and display the results (PASS/FAIL).
  4. Save Results: After a test, save the results to the internal memory or a connected USB drive.

3.2 Using Wi-Fi Connectivity

The integrated Wi-Fi allows for wireless data transfer and firmware updates. To connect:

  1. Navigate to "Settings" > "Network" > "Wi-Fi".
  2. Select your desired network and enter the password if prompted.
  3. Once connected, you can upload test results to LinkWare Live or download firmware updates.

4. Maintenance

4.1 Cleaning

Clean the unit's exterior with a soft, damp cloth. Do not use abrasive cleaners or solvents. Keep the display screen clean and free of dust and debris.

4.2 Firmware Updates

Regularly check for and install firmware updates to ensure optimal performance and access to the latest features and test limits. Updates can be performed via Wi-Fi or by connecting to a computer with LinkWare PC software.

4.3 Battery Care

To prolong battery life, avoid fully discharging the batteries frequently. Store the unit in a cool, dry place when not in use for extended periods, ensuring the batteries have a partial charge.

5. Troubleshooting

ProblemPossible CauseSolution
Unit does not power on.Low or depleted battery.Connect to power adapter and charge the battery.
Test fails unexpectedly.Incorrect test limit selected; faulty cable or connection; dirty test port.Verify test limit settings. Inspect and clean cable connections and test ports. Replace faulty cables.
Wi-Fi connection issues.Incorrect Wi-Fi password; out of range; network interference.Re-enter Wi-Fi password. Move closer to the access point. Check network settings.
Slow performance.Outdated firmware; excessive stored test results.Update firmware. Transfer old test results to LinkWare Live or PC and delete from unit.

6. Specifications

  • Model: DSX2-5000/GLD
  • Brand: Fluke Networks
  • Power Source: Corded Electric (for charging)
  • Package Dimensions: 16 x 15 x 11 inches
  • Weight: Approximately 17.95 Pounds
  • ASIN: B07BXZT1Q
  • UPC: 754082144007
  • Date First Available: April 4, 2018

7. Warranty and Support

The Fluke Networks DSX2-5000/GLD comes with a manufacturer's warranty. For detailed warranty information, product support, or service, please visit the official Fluke Networks website or contact their customer service department.

For additional resources and to register your product, visit: Fluke Networks Store on Amazon