Cook Rite ATSP-18-2L

Cook Rite ATSP-18-2L Two Burner Stock Pot Stove User Manual

Model: ATSP-18-2L | Brand: Cook Rite

1. Important Safety Information

Please read this manual thoroughly before installing, operating, or servicing this appliance. Failure to follow these instructions may result in property damage, personal injury, or death.

  • WARNING: For your safety, do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. Read the installation, operating, and maintenance instructions thoroughly before installing or servicing this equipment.
  • This appliance is designed for commercial use only. Ensure proper ventilation is provided in accordance with local and national codes.
  • Only qualified and authorized personnel should install and service this appliance.
  • Always keep the area around the appliance clear and free from combustible materials.

2. Product Overview

The Cook Rite ATSP-18-2L is a robust two-burner stock pot stove designed for commercial kitchen environments. This countertop unit features durable stainless steel construction and provides a total of 160,000 BTU, making it suitable for high-volume cooking tasks. Each burner operates independently with manual controls, offering precise heat management for various culinary applications.

Key Features:

  • Two high-performance burners.
  • Total 160,000 BTU output.
  • Durable stainless steel construction.
  • Independent manual controls for each burner.
  • Designed for countertop installation.

3. Setup and Installation

3.1 Unpacking

Carefully remove the appliance from its packaging. Inspect the unit for any shipping damage. Report any damage immediately to the carrier and your dealer. Retain all packaging materials for inspection.

3.2 Location and Clearance

Place the stove on a stable, level, non-combustible countertop. Ensure adequate clearance from combustible walls and materials. Consult local fire codes for specific clearance requirements. The appliance must be installed under an appropriate commercial ventilation hood system.

3.3 Gas Connection

This Cook Rite ATSP-18-2L model is designed for Liquid Propane (LP) gas. Installation must be performed by a qualified gas technician in accordance with all local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1.

  • Ensure the gas supply line is of adequate size to provide the necessary gas volume and pressure.
  • Install the provided gas pressure regulator. For LP gas, the regulator should be set to 10 inches Water Column (w.c.).
  • All connections must be sealed with a pipe joint compound suitable for LP gas.
  • After connecting, check all gas connections for leaks using a soap solution. NEVER use an open flame to check for leaks. Bubbles indicate a leak. Tighten connections until no bubbles appear.

4. Operating Instructions

4.1 Before Initial Use

Before operating, ensure all installation steps are complete, gas connections are secure, and the area is properly ventilated.

4.2 Lighting the Burners

  1. Ensure all burner control knobs are in the "OFF" position.
  2. Open the main gas supply valve to the appliance.
  3. Push in and turn the desired burner control knob counter-clockwise to the "PILOT" position.
  4. Using a long match or lighter, ignite the pilot flame located near the burner. Hold the flame until the pilot is steadily lit.
  5. Once the pilot is lit, turn the control knob further counter-clockwise to the "ON" position. The main burner should ignite.
  6. Adjust the flame height by rotating the control knob to achieve the desired heat level.

4.3 Shutting Down

To turn off a burner, rotate its control knob clockwise to the "OFF" position. For extended periods of non-use, close the main gas supply valve to the appliance.

5. Maintenance

Regular cleaning and maintenance will ensure the longevity and efficient operation of your Cook Rite stock pot stove.

5.1 Daily Cleaning

  • Allow the stove to cool completely before cleaning.
  • Remove grates and burner heads. Wash them with warm, soapy water. Rinse thoroughly and dry completely before reassembling.
  • Wipe down all stainless steel surfaces with a damp cloth and a mild, non-abrasive detergent. Dry immediately with a soft cloth to prevent water spots and streaks.
  • Do not use abrasive cleaners, steel wool, or scouring pads, as these can scratch and damage the stainless steel finish.

5.2 Burner Maintenance

  • Periodically inspect the burner ports for any food debris or blockages. Use a wire brush or a stiff wire to clear any obstructions.
  • Ensure burner heads are properly seated and aligned after cleaning or reassembly to ensure even flame distribution.

5.3 Regular Inspection

Schedule annual professional inspection and service by a qualified technician to ensure all components are functioning correctly and safely.

6. Troubleshooting

Before calling for service, please review the following common issues and their solutions:

ProblemPossible CauseSolution
Burner does not lightMain gas supply valve closed
Pilot light not lit
Clogged burner ports
Low gas pressure
Open main gas supply valve
Relight pilot light
Clean burner ports
Contact gas technician
Uneven flameClogged burner ports
Improperly seated burner head
Clean burner ports
Realign burner head
Gas odor detectedGas leakImmediately shut off gas supply. Ventilate area. Do not operate electrical switches. Contact a qualified gas technician immediately.

7. Specifications

Detailed specifications for the Cook Rite ATSP-18-2L (LP) model are provided below. Refer to the technical diagram for dimensions and component layout.

Technical specifications and diagrams for Cook Rite stock pot stoves, including warranty and certification details.

Image: Technical specifications, dimensions, warranty, and certifications for Cook Rite ATSP-18 series stock pot stoves.

SpecificationDetail (ATSP-18-2L LP)
ModelATSP-18-2L
Burners and Control Method2 Burner Independent Manual control
Gas TypeLP (Liquid Propane)
Intake-tube Pressure (in.W.C.)10
Nozzle NoLP49
Per BTU (B.T.U./h)40,000
Total BTU (B.T.U./h)160,000
Regulator10" w.c.
Net Weight (LBS)201.7
Packing Dimension (inch)20.9*45.7*20.1
Gross Weight (LBS)220.5
MaterialStainless Steel
Installation TypeCountertop

8. Warranty and Support

8.1 Warranty Information

This Cook Rite ATSP-18-2L appliance comes with a 1 Year Parts and Labor Warranty. This warranty covers defects in materials and workmanship under normal use and service. Please retain your proof of purchase for warranty claims.

8.2 Certifications

The Cook Rite ATSP-18-2L is certified to meet high safety and sanitation standards:

  • Conforms to ANSI STD Z83.11b-2009(2011)
  • Certified to CSA STD 1.8b-2009(2011)
  • Conforms to NSF/ANSI STD.4
  • ETL Listed for US and Sanitation (Intertek 4003935)

8.3 Customer Support

For technical assistance, parts, or warranty claims, please contact your authorized Cook Rite dealer or service provider. If purchased through Amazon, support may be available from the seller, Lucky Kitchen Supply.

Ask a question about this manual