Exell Battery OmniCel ER34615

OmniCel ER34615 Lithium Battery User Manual

Model: OmniCel ER34615 | Brand: Exell Battery

1. Product Overview

The OmniCel ER34615 is a high-capacity 3.6V 19Ah Size D Lithium Thionyl Chloride (Li-SOCl2) battery designed for long-term, reliable power in various applications. This battery features pre-attached wire leads for easy integration into compatible devices. It is commonly used in carbon monoxide detectors, intrusion sensors, invisible fencing systems, emergency backup power units, data collection devices, and AMR (Automatic Meter Reading) add-ons.

Four OmniCel ER34615 D-size lithium batteries with wire leads

Figure 1.1: Four OmniCel ER34615 D-size lithium batteries, showcasing their compact design and integrated wire leads for convenient installation.

2. Safety Information

Please read and understand all safety precautions before handling or installing the battery. Failure to follow these instructions may result in fire, explosion, electric shock, or other hazards.

  • Do Not Recharge: This is a non-rechargeable battery. Attempting to recharge it may cause leakage, fire, or explosion.
  • Proper Polarity: Always observe correct polarity (+ and -) when installing the battery. Incorrect installation can damage the device and the battery.
  • Avoid Short Circuits: Do not short-circuit the battery terminals with metal objects. This can cause excessive heat, fire, or explosion.
  • Temperature Limits: Do not expose the battery to extreme temperatures (above 85°C or below -60°C) or direct sunlight. Store in a cool, dry place.
  • Disposal: Dispose of used batteries according to local regulations. Do not incinerate or mutilate batteries.
  • Keep Away from Children: Store batteries out of reach of children and pets. If swallowed, seek immediate medical attention.
  • Handle with Care: Do not drop, puncture, or disassemble the battery. If the battery casing is damaged, avoid contact with the internal contents.

3. Setup and Installation

The OmniCel ER34615 battery comes with pre-attached wire leads for simplified connection. Ensure your device is powered off before installation.

  1. Identify Terminals: Locate the positive (+) and negative (-) connection points on your device. The battery's wire leads are typically color-coded (e.g., red for positive, black for negative).
  2. Connect Leads: Carefully connect the positive wire lead from the battery to the positive terminal of your device. Similarly, connect the negative wire lead to the negative terminal. Ensure connections are secure and free from loose strands.
  3. Secure Battery: Place the battery securely within the device's battery compartment, ensuring it does not move freely or come into contact with other components that could cause a short circuit.
  4. Verify Installation: Once connected, double-check all connections for correct polarity and secure fit.
Side view of OmniCel ER34615 battery with wire leads

Figure 3.1: Side view of the OmniCel ER34615 battery, showing the integrated wire leads ready for connection.

Close-up of OmniCel ER34615 battery label and wire leads

Figure 3.2: Detailed view of the battery's label, indicating "3.6 Volts" and model "ER34615 D", along with the twisted wire leads.

4. Operating Instructions

Once properly installed, the OmniCel ER34615 battery will provide continuous power to your compatible device. As a primary (non-rechargeable) battery, its operation is passive, supplying consistent voltage until its capacity is depleted.

  • Ensure the device requiring power is designed for a 3.6V D-size lithium battery.
  • The battery will begin supplying power immediately upon correct installation and device activation.
  • Monitor your device's low battery indicator, if available, to determine when replacement is necessary.

5. Maintenance

These batteries require minimal maintenance, but proper handling and storage are crucial for maximizing their lifespan and ensuring safety.

  • Storage: Store unused batteries in their original packaging in a cool, dry place, away from direct sunlight and extreme temperatures. Avoid storing with metal objects that could cause a short circuit.
  • Inspection: Periodically inspect installed batteries for any signs of damage, leakage, or corrosion. If any issues are observed, replace the battery immediately.
  • Cleaning: If necessary, gently wipe the battery's exterior with a dry, clean cloth. Do not use liquids or abrasive cleaners.
  • Replacement: Replace batteries when your device indicates low power or ceases to function correctly. Do not mix old and new batteries, or different types of batteries.

6. Troubleshooting

If your device is not functioning after battery installation, consider the following troubleshooting steps:

ProblemPossible CauseSolution
Device does not power on.Incorrect battery polarity.Verify that the positive (+) and negative (-) leads are connected correctly.
Device does not power on.Battery is depleted or faulty.Replace the battery with a new one. Ensure it is an OmniCel ER34615 or equivalent.
Device powers on but functions intermittently.Loose wire connections.Check that the wire leads are securely connected to the device's terminals.
Battery appears damaged or leaking.Physical damage or internal fault.Immediately remove the battery (wearing protective gloves if necessary) and dispose of it safely according to local regulations. Do not attempt to use a damaged battery.

7. Specifications

Detailed technical specifications for the OmniCel ER34615 battery:

  • Model: OmniCel ER34615
  • Battery Type: Lithium Thionyl Chloride (Li-SOCl2)
  • Voltage: 3.6 Volts
  • Nominal Capacity: 19 Ampere-hours (19Ah)
  • Size: D
  • Diameter: Approximately 32.9 mm (1.29 inches)
  • Length: Approximately 61.5 mm (2.42 inches)
  • Weight: Approximately 3.2 ounces (90.7 grams) per battery
  • Operating Temperature Range: Typically -60°C to +85°C (Consult manufacturer for exact range)
  • Compatible Devices: Carbon Monoxide Detectors, Intrusion Sensors, Invisible Fencing, Emergency Backup, Data Collection, AMR Add-ons, Alarm Systems, Smoke Alarms, Torches.
End view of OmniCel ER34615 battery with wire leads

Figure 7.1: End view of the OmniCel ER34615 battery, showing the positive terminal and wire lead attachment point.

OmniCel ER34615 battery standing upright with wire leads

Figure 7.2: OmniCel ER34615 battery shown upright, highlighting its D-size form factor and the integrated wire leads.

8. Warranty and Support

For specific warranty information regarding your OmniCel ER34615 batteries, please refer to the documentation provided at the time of purchase or contact the seller directly. Exell Battery, as the brand, typically provides support for their products.

For further assistance or technical inquiries, please visit the official Exell Battery website or contact their customer support.

Exell Battery Official Store: Visit Store on Amazon

© 2023 Exell Battery. All rights reserved. Information subject to change without notice.

Related Documents - OmniCel ER34615

Preview ADT Wireless Sensor Battery Replacement Guide for Safewatch Systems
This guide provides detailed instructions for replacing batteries in ADT Safewatch wireless sensors used in residential and small business security systems. It includes general steps, critical safety warnings, model-specific procedures for various detectors and transmitters, and information on battery disposal and recycling. Learn how to identify low battery alerts and maintain your security system's functionality.
Preview Kidde Smart Carbon Monoxide Alarm COPDW: Plug-in with Battery Backup
Learn about the Kidde Smart Carbon Monoxide Alarm (Model COPDW), featuring real-time notifications, a backlit display, and plug-in design with AA battery backup. Get essential safety information and technical specifications.
Preview Kidde i12010SCO Combination Smoke and Carbon Monoxide Alarm User Guide
Comprehensive user guide for the Kidde i12010SCO Combination Smoke and Carbon Monoxide Alarm, covering features, installation, operation, safety information, maintenance, and warranty.
Preview Allied Battery Lithium Sizing Guide for Golf Carts
A comprehensive guide to sizing Allied Battery 36V lithium battery packs for various golf cart types, including Economy, Modified, and Highly Modified configurations, detailing estimated range based on battery capacity.
Preview Defender Carbon Monoxide Alarm Owner's Manual - CA6100 & CA6150
This owner's manual provides comprehensive instructions for the Defender CA6100 and CA6150 sealed lithium battery powered carbon monoxide alarms. It covers installation, operation, features, specifications, carbon monoxide information, recommended locations, locations to avoid, testing procedures, alarm signals, troubleshooting, limitations, safety habits, and the ten-year limited warranty.
Preview Kidde 900-0120 AC Wire-In Carbon Monoxide Alarm with Battery Backup - Features, Specs, and Installation
Comprehensive details on the Kidde 900-0120 AC Wire-In Carbon Monoxide Alarm, including its features, consumer benefits, contractor-friendly installation, technical specifications, and ordering information. This alarm offers battery backup and interconnectivity for enhanced home safety.

Ask a question about this manual