Rexim 316554

Rexim 24V 150W FDS DZE Halogen Bulb Instruction Manual

Model: 316554

1. Introduction

This manual provides essential information for the safe and effective use of the Rexim 24V 150W FDS DZE Halogen Bulb. This specialty bulb is designed for specific dental light and lamp applications, including DENTECH Light Dental Chairs, Efos 4074 Dental Lamps, and Midwest NSK Power Optic 5974 systems. It features a 2-pin GZ9.5 ceramic base and delivers a crisp, bright light suitable for professional environments.

2. Safety Information

Please read and understand all safety instructions before handling or installing the bulb. Failure to follow these instructions may result in electric shock, fire, or personal injury.

  • Electrical Hazard: Always disconnect power to the fixture before installing, removing, or cleaning the bulb.
  • Burn Hazard: Halogen bulbs operate at high temperatures. Allow the bulb to cool completely before handling. Do not touch the bulb with bare hands during operation or immediately after turning off.
  • Fragile: Handle the bulb carefully. Avoid dropping or subjecting it to impact.
  • Cleanliness: Do not touch the glass envelope of the bulb with bare hands. Oils from your skin can create hot spots, leading to premature bulb failure. Use a clean cloth or gloves if contact is unavoidable.
  • Compatibility: Ensure the bulb's voltage (24V) and wattage (150W) match the requirements of your fixture. Using an incorrect bulb can damage the fixture or cause a fire.
  • Disposal: Dispose of used bulbs according to local regulations.

3. Product Overview

The Rexim 24V 150W FDS DZE Halogen Bulb is a high-performance light source designed for specialized applications. Key features include:

  • Type: Halogen, T4 shape.
  • Base: GZ9.5 2-pin ceramic base.
  • Power: 24 Volts, 150 Watts.
  • ANSI Code: FDS/DZE.
  • Filament: C BAR 6.
  • Operating Position: BD/HORIZ (Burn Down/Horizontal).
Two Rexim 24V 150W FDS DZE halogen bulbs with GZ9.5 ceramic bases.

This image displays two Rexim 24V 150W FDS DZE halogen bulbs. Each bulb features a clear glass envelope, a ceramic base, and two metal pins for connection. The base is marked with 'FDS 24V150W'.

4. Setup and Installation

Follow these steps to safely install the Rexim halogen bulb:

  1. Power Off: Ensure the power supply to the light fixture is completely disconnected at the circuit breaker or wall switch.
  2. Cool Down: If replacing an existing bulb, allow the old bulb to cool down completely before touching it.
  3. Remove Old Bulb: Carefully grasp the old bulb by its ceramic base (not the glass) and gently pull it straight out from the socket. Avoid twisting if the socket is designed for straight insertion.
  4. Prepare New Bulb: Remove the new Rexim bulb from its packaging. Handle the bulb by its ceramic base only. If you accidentally touch the glass envelope, clean it with a lint-free cloth moistened with rubbing alcohol and allow it to dry completely before installation.
  5. Insert New Bulb: Align the two pins of the new bulb with the corresponding holes in the fixture's socket. Gently push the bulb straight into the socket until it is fully seated. Do not force the bulb.
  6. Secure Fixture: Reassemble any covers or protective elements of the light fixture.
  7. Restore Power: Turn the power supply back on.
  8. Test: Activate the light fixture to ensure the new bulb is functioning correctly.

5. Operating Instructions

Once properly installed, the Rexim 24V 150W FDS DZE Halogen Bulb operates in conjunction with your compatible dental light or lamp fixture. No special operating procedures are required for the bulb itself beyond the fixture's standard controls.

  • Ensure the fixture's power switch is in the 'ON' position to illuminate the bulb.
  • The bulb will reach full brightness almost instantly.
  • Avoid frequent on/off cycling, as this can reduce the bulb's lifespan.

6. Maintenance

Proper maintenance ensures optimal performance and longevity of your halogen bulb.

  • Cleaning: If the glass envelope of the bulb becomes dirty or smudged, turn off the power and allow the bulb to cool. Carefully remove the bulb and clean the glass with a soft, lint-free cloth moistened with rubbing alcohol. Ensure the bulb is completely dry before reinstallation.
  • Inspection: Periodically inspect the bulb for any signs of damage, such as cracks in the glass or discoloration. Replace damaged bulbs immediately.
  • Fixture Maintenance: Regularly clean the light fixture's reflectors and lenses according to the fixture manufacturer's instructions to maintain light output efficiency.

7. Troubleshooting

If the bulb does not light after installation, consider the following common issues:

  • No Power: Check if the power supply to the fixture is on. Verify that the circuit breaker has not tripped.
  • Improper Installation: Ensure the bulb is fully and correctly seated in the socket. The pins must make proper contact.
  • Incorrect Bulb: Confirm that the installed bulb matches the voltage and wattage requirements of your fixture.
  • Blown Bulb: Even new bulbs can sometimes be faulty. If possible, test the bulb in another compatible fixture or try a different new bulb.
  • Fixture Fault: If multiple bulbs fail to light, the issue might be with the light fixture itself (e.g., faulty socket, wiring, or transformer). Consult a qualified technician for fixture repair.

8. Specifications

SpecificationDetail
BrandRexim
Model Number316554
Light TypeHalogen
Voltage24 Volts
Wattage150 Watts
Bulb Shape SizeT4 (Tubular)
Bulb BaseGZ9.5 (2-pin ceramic)
ANSI CodeFDS/DZE
FilamentC BAR 6
Operating PositionBD/HORIZ
Brightness3100 Lumens
Color Temperature4600 Kelvin
FinishClear
Product Dimensions2 x 1 x 1 inches
Indoor/Outdoor UsageIndoor
UPC638037122411

9. Warranty and Support

For warranty information or technical support regarding your Rexim 24V 150W FDS DZE Halogen Bulb, please contact the seller or retailer from whom you purchased the product. Keep your purchase receipt as proof of purchase.

© 2023 Rexim. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.