FY3224S

Generic DANIU FY3224S 24MHz Dual-channel Arbitrary Waveform DDS Function Signal Generator User Manual

Model: FY3224S (FFC-BG-1157268)

1. Introduction

This manual provides comprehensive instructions for the safe and efficient operation of the Generic DANIU FY3224S Dual-channel Arbitrary Waveform DDS Function Signal Generator. This device is designed to generate various waveforms, including sine, square, triangle, pulse, and arbitrary waveforms, with a maximum frequency of 24MHz. It also features frequency sweep and counter functions, making it suitable for a wide range of electronic testing and experimental applications.

2. Safety Information

Please read and understand all safety precautions before operating the device. Failure to follow these instructions may result in electric shock, fire, or damage to the product.

3. Package Contents

Verify that all items listed below are present in your package:

DANIU FY3224S Function Signal Generator with included accessories: power cable, BNC cables, USB cable, and software CD.

Figure 3.1: DANIU FY3224S Function Signal Generator and its accessories.

4. Product Overview

Familiarize yourself with the main components and controls of the signal generator.

4.1 Front Panel

Front view of the DANIU FY3224S Function Signal Generator, showing the display, control buttons, and output ports.

Figure 4.1: Front Panel of the FY3224S.

4.2 Rear Panel

The rear panel typically houses the power input jack and potentially a USB communication port for PC connectivity.

5. Setup

  1. Power Connection: Connect the provided power adapter to the power input jack on the rear panel of the signal generator. Plug the adapter into a suitable AC power outlet.
  2. Initial Power On: Flip the ON/OFF switch on the front panel to the 'ON' position. The LCD display should illuminate, showing the startup screen and then the default waveform settings.
  3. Output Connection: Connect the BNC output cables (CH1 or CH2) to your desired test equipment (e.g., oscilloscope, frequency counter, circuit under test).
  4. USB Connection (Optional): If using PC software for control, connect the USB data cable from the signal generator's USB port to your computer. Install the necessary drivers and software from the provided CD or manufacturer's website.

6. Operating Instructions

6.1 Basic Operation

6.2 Waveform Generation

  1. Press the WAVE button to enter the waveform selection menu.
  2. Turn the control knob to select the desired waveform type (e.g., Sine, Square, Triangle, Pulse, Arbitrary). Press the knob to confirm.
  3. Press the PARM button to access waveform parameters.
  4. Adjust parameters such as:
    • Frequency (FREQ): Set the output frequency.
    • Amplitude (AMPL): Set the peak-to-peak voltage.
    • Offset (OFFSET): Set the DC offset voltage.
    • Duty Cycle (DUTY): For square/pulse waves.
    • Phase (PHASE): For dual-channel synchronization.
  5. Ensure the output channel (CH1 or CH2) is enabled if there's a dedicated button or menu option for it.

6.3 Frequency Sweep Function

  1. Press the SWEEP button.
  2. Set the Start Frequency and End Frequency using the control knob and directional buttons.
  3. Set the Sweep Time (duration of the sweep).
  4. Select the Sweep Mode (e.g., Linear, Logarithmic).
  5. Activate the sweep function.

6.4 Counter Function

  1. Connect the external signal to be measured to the Input Port.
  2. Press the COUNT button.
  3. The display will show the frequency or period of the input signal.
  4. Adjust settings like gate time or coupling if available in the counter menu.

7. Maintenance

8. Troubleshooting

ProblemPossible CauseSolution
Device does not power on.Power cable not connected; power outlet faulty; power switch off.Check power cable connection; try a different outlet; ensure power switch is ON.
No output signal.Output channel disabled; incorrect parameters; faulty cable.Ensure channel is enabled; verify frequency/amplitude settings; test with a different BNC cable.
Incorrect frequency/amplitude readings on external device.Improper impedance matching; external device calibration issue.Ensure 50Ω termination if required; check external device settings and calibration.
Counter function not working.Input signal too weak/strong; incorrect input connection.Adjust input signal level; ensure signal is connected to the correct input port.

9. Specifications

10. Warranty and Support

This product is covered by a standard manufacturer's warranty. For specific warranty terms, please refer to the documentation included with your purchase or contact the seller directly. For technical support, troubleshooting assistance beyond this manual, or inquiries regarding repairs, please contact the retailer or manufacturer's customer service department.

Related Documents - FY3224S

Preview FeelTech FY3200S Series Dual Channel Function/Arbitrary Waveform Generator User's Manual
Comprehensive user's manual for the FeelTech FY3200S Series Dual Channel Function/Arbitrary Waveform Generator, detailing its features, specifications, and operation.
Preview FeelTech FY3200S Series Dual-channel DDS Function / Arbitrary Waveform Signal Generator User's Manual
User's manual for the FeelTech FY3200S Series Dual-channel DDS Function and Arbitrary Waveform Signal Generator. This document provides detailed information on the instrument's features, technical specifications, operating procedures, safety precautions, and accessories.
Preview FeelTech FY3200S Series Dual Channel Function/Arbitrary Waveform Generator User's Manual
User's manual for the FeelTech FY3200S Series Fully Numerical Control Dual Channel Function/Arbitrary Waveform Generator, detailing its features, specifications, operation, and safety information.