Introduction
This manual provides instructions for the safe installation, operation, and maintenance of your Lindby Violetta Wall Lamp. The Lindby Violetta wall lamp is designed to provide elegant lighting, particularly suitable for bathrooms, featuring an opal glass shade that diffuses a soft light. Please read this manual thoroughly before installation and retain it for future reference.
Safety Instructions
- Electrical Safety: Installation must be performed by a qualified electrician in accordance with all local and national electrical codes. Always disconnect power at the main circuit breaker before installation, maintenance, or bulb replacement.
- Voltage: Ensure the supply voltage matches the lamp's operating voltage (230V).
- Protection Class: This lamp has an IP44 protection rating, making it suitable for use in bathrooms (splash-proof). Do not expose to direct water jets.
- Bulb Type: Use only G9 base bulbs with a maximum wattage of 33W. The light source is not included.
- Handling: Handle glass components with care to prevent breakage.
Package Contents
Verify that all components are present before beginning installation:
- Lamp fixture (metal base with G9 socket)
- Opal glass shade
- Mounting hardware (screws, wall plugs)
- Instruction manual
Note: A G9 light bulb is not included and must be purchased separately.
Setup and Installation
Follow these steps for proper installation:
- Prepare for Installation:
Turn off the main power supply at the circuit breaker before starting any electrical work. Ensure the power is off by testing the circuit. - Disassemble the Lamp:
Carefully remove the glass shade from the lamp fixture. You may need to unscrew a retaining ring or gently twist the shade. Keep all parts in a safe place.
Image: Disassembled lamp components, including the metal base with the G9 socket and the separate opal glass shade.
- Mark Mounting Position:
Hold the lamp base against the wall at the desired installation location. Mark the positions for drilling the mounting holes. - Drill Holes and Insert Wall Plugs:
Drill holes at the marked positions using an appropriate drill bit for your wall type. Insert the provided wall plugs into the drilled holes. - Connect Wiring:
Open the wiring compartment on the lamp base. Connect the household electrical wires to the terminal block inside the lamp base. Ensure correct polarity (Live, Neutral, Earth) according to local wiring regulations. Secure all connections tightly.
Image: View of the lamp's internal wiring compartment, showing the terminal block where electrical connections are made.
- Mount the Lamp Base:
Attach the lamp base to the wall using the provided screws, ensuring it is securely fastened. - Install the G9 Bulb:
Insert a G9 base light bulb (max 33W) into the G9 socket. Ensure it is firmly seated.
Image: Detailed view of the G9 bulb socket on the lamp fixture, ready for bulb insertion.
- Attach the Glass Shade:
Carefully reattach the opal glass shade to the lamp fixture, securing it as it was originally removed. - Restore Power:
Once installation is complete and all connections are secure, restore power at the main circuit breaker.
Operating Instructions
The Lindby Violetta Wall Lamp operates via a standard wall switch connected to its electrical circuit. Flip the wall switch to turn the lamp ON or OFF. If connected to a compatible dimmer switch, the light intensity can be adjusted accordingly.
Maintenance
- Cleaning: Disconnect power before cleaning. Wipe the lamp with a soft, dry cloth. For stubborn marks, a slightly damp cloth can be used, followed by immediate drying. Do not use abrasive cleaners or solvents.
- Bulb Replacement: Always disconnect power before replacing the bulb. Allow the bulb to cool completely before touching. Gently remove the old G9 bulb and insert a new G9 bulb (max 33W).
Troubleshooting
- Lamp does not light up:
- Check if the power supply is switched on at the circuit breaker and wall switch.
- Ensure the light bulb is correctly inserted and not faulty. Replace the bulb if necessary.
- Verify that the electrical connections are secure. If unsure, consult a qualified electrician.
- Light flickers:
- Ensure the bulb is fully seated in the socket.
- Check for loose wiring connections.
- If using a dimmer, ensure it is compatible with the G9 bulb type.
Specifications
| Model | 9641007 (Violetta) |
| Brand | Lindby |
| Material | Metal, Glass (shade) |
| Finish | Satin, Chrome |
| Dimensions (L x W x H) | 15.5 cm x 14 cm x 21 cm |
| Socket Type | G9 |
| Max. Wattage | 1 x 33W |
| Operating Voltage | 230V |
| Protection Class | IP44 (Splash-proof) |
| Mounting Type | Wall Mounting, Surface Mounted |
| Light Source Included | No |
| Control Method | Touch (typically via compatible wall dimmer) |
Warranty Information
Specific warranty details for this product are not provided in the available information. Please refer to your purchase documentation or contact your retailer for warranty terms and conditions.
Support
For technical assistance or further inquiries, please contact the retailer from whom you purchased the Lindby Violetta Wall Lamp. Please have your model number (9641007) and purchase details ready when contacting support.