Samlex America RC-300

Samlex RC-300 Remote Control User Manual

For PST 3000 Inverter Series

1. Introduction

This manual provides comprehensive instructions for the installation, operation, and maintenance of your Samlex RC-300 Remote Control. The RC-300 is designed for use with Samlex PST 3000 Inverter Series models, offering convenient monitoring and control of your inverter system.

2. Safety Information

Please read and understand all safety instructions before installing or operating the RC-300 remote control. Failure to follow these instructions may result in damage to the product, inverter, or personal injury.

  • Ensure the inverter is turned off and disconnected from all power sources before connecting or disconnecting the remote control.
  • Do not expose the remote control to water, moisture, or extreme temperatures.
  • Do not attempt to open or repair the remote control. Refer all servicing to qualified personnel.
  • Use only the provided cable for connection to the inverter.

3. Product Overview

The Samlex RC-300 is an optional remote control unit that provides real-time monitoring and control capabilities for compatible Samlex PST 3000 series inverters. It features an LCD display and indicator LEDs to provide essential system information.

Samlex RC-300 Remote Control front panel with LCD display, display button, power button, and LED indicators for overload, over temperature, and power.

Figure 1: Samlex RC-300 Remote Control Front Panel
The image displays the front panel of the Samlex RC-300 remote control. It features an LCD screen for displaying various inverter parameters, a 'DISPLAY' button to cycle through readings, a power button, and three LED indicators for 'OVERLOAD' (red), 'OVER TEMP' (yellow), and 'POWER' (green). The screen can show Voltage (V), Current (A), Frequency (Hz), Power (W), Apparent Power (VA), and Power Factor (PF).

3.1 Components

  • LCD Display: Shows AC Voltage, AC Current, Frequency, Power (Watts), Apparent Power (VA), and Power Factor.
  • DISPLAY Button: Cycles through the various parameters on the LCD.
  • Power Button: Controls the ON/OFF state of the connected inverter.
  • OVERLOAD LED (Red): Illuminates when the inverter is in an overload condition.
  • OVER TEMP LED (Yellow): Illuminates when the inverter is experiencing an over-temperature condition.
  • POWER LED (Green): Illuminates when the inverter is powered on and operating normally.
  • RJ-50 Cable: 25-foot (7.6m) cable for connecting the remote control to the inverter.

4. Setup and Installation

Follow these steps to properly connect your RC-300 remote control to your Samlex PST 3000 series inverter.

  1. Ensure Inverter is Off: Before connecting the remote control, ensure your Samlex PST 3000 series inverter is turned off and disconnected from all power sources (DC input and AC output).
  2. Locate Remote Port: Identify the remote control port on your Samlex PST 3000 series inverter. Refer to your inverter's manual for the exact location.
  3. Connect Cable: Insert one end of the provided RJ-50 (10P10C) cable into the remote control port on the inverter.
  4. Connect Remote Control: Insert the other end of the RJ-50 cable into the corresponding port on the back of the RC-300 remote control.
  5. Secure Connection: Ensure both connections are secure.
  6. Power On Inverter: Reconnect power to your inverter and turn it on. The RC-300 remote control should now be operational.

5. Operating Instructions

Once connected, the RC-300 allows you to monitor and control your inverter remotely.

5.1 Powering the Inverter On/Off

  • To turn the inverter ON, press and hold the Power Button (⏻) on the RC-300 for approximately 3 seconds. The green POWER LED will illuminate.
  • To turn the inverter OFF, press and hold the Power Button (⏻) again for approximately 3 seconds. The green POWER LED will turn off.

5.2 Monitoring Inverter Parameters

The LCD display on the RC-300 shows various operational parameters of the inverter.

  • Press the DISPLAY button to cycle through the available readings. Each press will advance to the next parameter.
  • The display will show: AC Voltage (V) → Active AC Current (A) → Frequency (Hz) → Power (Watts) → Apparent Power (VA) → Power Factor (PF).

5.3 LED Indicators

  • POWER (Green): Indicates the inverter is powered on and functioning.
  • OVERLOAD (Red): Indicates the inverter is experiencing an overload condition. Reduce the load connected to the inverter immediately.
  • OVER TEMP (Yellow): Indicates the inverter's internal temperature is too high. Ensure adequate ventilation around the inverter.

6. Maintenance

The Samlex RC-300 remote control requires minimal maintenance.

  • Keep the unit clean and free from dust. Use a soft, dry cloth for cleaning.
  • Do not use abrasive cleaners or solvents.
  • Ensure the cable connections remain secure.

7. Troubleshooting

If you encounter issues with your RC-300 remote control, refer to the following common problems and solutions.

ProblemPossible CauseSolution
Remote control display is blank.Inverter is off or not powered.
Cable is loose or damaged.
Ensure the inverter is powered on.
Check the RJ-50 cable connection at both the inverter and the remote control. Replace cable if damaged.
Inverter does not turn on/off via remote.Incorrect button press duration.
Communication issue.
Press and hold the Power Button for approximately 3 seconds.
Verify cable connection. Restart inverter.
OVERLOAD LED is illuminated.Too many devices connected to the inverter.Reduce the load connected to the inverter. Refer to your inverter's manual for maximum load capacity.
OVER TEMP LED is illuminated.Inverter is overheating.Ensure the inverter has adequate ventilation. Clear any obstructions from cooling vents. Reduce load if necessary.

If the problem persists after attempting these solutions, please contact Samlex America customer support.

8. Specifications

FeatureSpecification
Model NumberRC-300
Compatible InvertersSamlex PST 3000-12, PST 300S-12E, PST 3000-24, PST 300S-24E
Display TypeLCD
Displayed ParametersAC Voltage (V), Active AC Current (A), Frequency (Hz), Power (Watts), Apparent Power (VA), Power Factor (PF)
Cable TypeRJ-50 (10P10C) Crossed/Rolled-Over
Cable Length7.6 meters (25 feet)
Operating Temperature0°C to 40°C (32°F to 104°F)
Item Weight1.92 ounces

9. Warranty Information

The Samlex RC-300 Remote Control comes with a 2-year warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use. It does not cover damage caused by misuse, accident, unauthorized modification, or improper installation. Please retain your proof of purchase for warranty claims.

10. Support

For technical assistance, warranty claims, or further information regarding your Samlex RC-300 Remote Control or compatible inverters, please contact Samlex America customer support. Refer to the official Samlex America website for current contact details and support resources.

Related Documents - RC-300

PreviewSamlex America Inverter Quick Reference Guide
A quick reference guide for Samlex America's Pure Sine Wave and Modified Sine Wave inverters, including PST, NTX, SAM, and EVO series. This guide provides model information, applications, and installation kit details.
PreviewSamlex America Inverter/Charger Quick Reference Guide
A quick reference guide comparing Samlex America's PST, SAM, NTX, and EVO series inverter/chargers. It details their features, applications, and installation kits.
PreviewSamlex ACR-300 Automatic Battery Separator - 300A Specifications
Detailed specifications and features for the SamlexAmerica ACR-300 Automatic Battery Separator, a microprocessor-controlled unit designed for 12/24 VDC systems with 300A continuous rating. Includes electrical specs, connections, environmental data, and compliance information.
PreviewSamlex Power MSK-10A Solar Charge Controller Owner's Manual
Comprehensive owner's manual for the Samlex Power MSK-10A Solar Charge Controller, detailing installation, operation, safety, and troubleshooting for 12V/24V Lead Acid and AGM batteries.
PreviewSamlex America ACR-160 Automatic Charge Separator Owner's Manual
Detailed owner's manual and installation guide for the Samlex America ACR-160 Automatic Charge Separator, covering its features, technical specifications, and wiring for RVs, boats, and service vans.
PreviewSamlex America ACR-160 Automatic Charge Separator: Owner's Manual & Installation Guide
This owner's manual for the Samlex America ACR-160 Automatic Charge Separator details its operation, installation, and technical specifications. Designed for starter and auxiliary battery systems in marine, RV, and service vehicles, the ACR-160 intelligently manages battery charging, prevents starting issues, and offers features like voltage-dependent switching and start assistance.