1. Product Overview

The FAAC 422 CBAC is a hydraulic swing gate opener designed for residential and light commercial applications. This robust operator is engineered for durability and quiet performance, capable of cycling up to 55 times per hour. It features a hydraulic lock in both opened and closed positions, a key-protected manual release mechanism, and is self-lubricating for extended operational life.

This unit is suitable for operating swing gates up to 10 feet (3 meters) long and weighing up to 900 lbs (410 kg). It can be used as a standalone operator for a single gate or integrated into a dual master/slave (bi-parting) gate system.

FAAC 422 CBAC Standard Hydraulic Swing Gate Opener unit

Image showing the compact design of the FAAC 422 CBAC hydraulic swing gate opener, ready for installation.

2. Safety Information

WARNING: Improper installation or use can cause serious injury or death. Read all instructions carefully before installation and operation.

  • Ensure all electrical connections are performed by a qualified electrician and comply with local codes and regulations.
  • Keep hands, feet, and clothing clear of the gate and gate opener at all times, especially during operation.
  • Do not allow children to play near the gate or operate the gate controls.
  • Regularly inspect the gate and opener for signs of wear, damage, or misalignment. Do not operate if damage is present.
  • In case of power failure or emergency, use the manual release mechanism as described in the operating instructions.
  • Always disconnect power to the unit before performing any maintenance or service.

3. Setup and Installation

Installation of the FAAC 422 CBAC hydraulic swing gate opener requires technical expertise and should ideally be performed by a certified installer. This section provides a general overview; refer to the comprehensive installation guide provided with the product for detailed instructions.

  1. Mounting the Operator: Securely attach the gate opener to the gate post and gate leaf using appropriate hardware, ensuring correct alignment and pivot points for smooth gate movement.
  2. Hydraulic Connections: Connect the hydraulic lines as per the detailed diagrams in the full installation manual. Ensure all connections are tight to prevent leaks.
  3. Electrical Wiring: Connect the 115 VAC power supply and control wiring to the operator's control board. Verify all connections are correct and insulated.
  4. Limit Switch Adjustment: Adjust the gate's open and close limits to ensure proper gate travel and prevent over-extension or slamming.
  5. Testing: Perform thorough operational tests to confirm the gate opens and closes smoothly, safety features are active, and the manual release functions correctly.

4. Operating Instructions

The FAAC 422 CBAC operator is designed for automated gate control. Operation typically involves a control panel, remote transmitter, or other access control devices (not included with the operator only unit).

4.1. Standard Operation

To open or close the gate, activate the control device (e.g., press a button on a remote or access panel). The gate will move smoothly to its fully open or closed position and then hydraulically lock.

4.2. Manual Release

In the event of a power outage or system malfunction, the gate can be operated manually using the key-protected release mechanism.

  1. Locate the manual release mechanism on the operator unit.
  2. Insert the provided key into the lock.
  3. Turn the key to disengage the hydraulic lock. The gate can now be moved by hand.
  4. To re-engage, move the gate to the desired position, turn the key back, and remove it. The hydraulic lock will re-engage automatically when power is restored or the system is reset.

5. Maintenance

Regular maintenance ensures the longevity and reliable operation of your FAAC 422 CBAC gate opener. While the unit is self-lubricating, periodic checks are recommended.

  • Monthly: Inspect the gate's movement for any obstructions, unusual noises, or signs of friction. Check all mounting hardware for tightness.
  • Quarterly: Verify the proper functioning of all safety devices (e.g., photocells, safety edges, if installed). Test the manual release mechanism.
  • Annually: Have a qualified technician inspect the hydraulic fluid levels and seals. Check electrical connections for corrosion or damage.
  • Keep the area around the gate and operator clear of debris, vegetation, and anything that could impede gate movement.

6. Troubleshooting

This section addresses common issues. For complex problems, contact a qualified technician.

ProblemPossible CauseSolution
Gate does not move.No power, remote battery dead, safety device activated, manual release engaged.Check power supply. Replace remote battery. Clear safety device path. Disengage manual release.
Gate opens partially or stops.Obstruction, limit switch misadjusted, low hydraulic fluid.Remove obstruction. Re-adjust limit switches. Contact technician for fluid check.
Unusual noises during operation.Friction, worn components, loose mounting.Inspect gate hinges and operator mounting. Contact technician for internal inspection.
Gate does not lock.Manual release engaged, hydraulic issue.Ensure manual release is fully disengaged. Contact technician.

7. Specifications

Model NumberFAAC-422-CBAC-STANDARD-SG-OPERATOR-ONLY
Input Voltage115 VAC (+10% -6%)
Power220 W
Current2 A
Motor Rotation Speed1400 r.p.m.
Rod Extension Speed0.5 in/sec (1.3 cm/sec)
Pump Flow Rate1 l/min
Traction and Thrust Force1124 lbf (500 daN)
Maximum Leaf Width10 ft (3 m)
Maximum Leaf Weight900 lb (410 Kg)
Usage Frequency55 cycles per hour
Operating Ambient Temperature4°F to 131°F (-20 °C to +55 °C)
Thermal Protection on Motor Winding248 °F (120 °C)
Protection ClassIP 55
Dimensions (L x D x H)38.8 x 4.7 x 3.3 in (987x120x85mm)
Item Weight25 pounds

8. Warranty and Support

For warranty information and technical support, please refer to the documentation provided with your purchase or contact the manufacturer directly. Keep your proof of purchase for warranty claims.

For assistance with installation, troubleshooting, or parts, contact your authorized FAAC dealer or the seller from whom you purchased this product.

© 2023 FAAC. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.