EXTRAUP PAS-30A

EXTRAUP Water Transfer Pump

Model: PAS-30A

1. Introduction

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your EXTRAUP 1/10HP Water Transfer Pump. Please read this manual thoroughly before operating the pump and retain it for future reference.

EXTRAUP 1/10HP Water Transfer Pump with included accessories

Image 1.1: The EXTRAUP 1/10HP Water Transfer Pump, showcasing its compact design, carry handle, and the included 6-foot inlet hose, water suction attachment, and impeller replacement kit.

2. Safety Information

WARNING: To reduce the risk of electric shock, fire, or injury, read all instructions before using this product.

  • Electrical Safety: Ensure the pump is connected to a properly grounded 115V/60Hz power outlet. Do not operate with damaged cords or plugs.
  • Liquid Compatibility: This pump is designed for CLEAN WATER ONLY. Do not pump flammable liquids, corrosive chemicals, or water containing large debris. Pumping flammable liquids can cause explosion or fire.
  • Submersion: This is a NON-SUBMERSIBLE pump. Do not submerge the pump in water or any other liquid. Keep the pump dry during operation.
  • Operating Environment: Operate the pump in a well-ventilated area. Avoid operating in freezing temperatures to prevent damage from ice expansion.
  • Supervision: Do not leave the pump unattended during operation.
  • Children and Pets: Keep children and pets away from the pump during operation.
Diagram showing correct and incorrect pump usage, including priming, hose connections, maximum suction depth, and a warning against submersion.

Image 2.1: Visual guide to safe operating practices, emphasizing the importance of priming, correct hose connections, understanding maximum suction depth, and the critical warning against submerging the pump.

3. Package Contents

Verify that all items are present and undamaged upon unpacking:

  • 1 x EXTRAUP 1/10HP Utility Water Transfer Pump
  • 1 x 6-foot Inlet Hose
  • 1 x Water Suction Attachment
  • 1 x Impeller Replacement Kit (includes impeller and gasket)
Diagram showing the pump and its included accessories: suction strainer, 6ft suction hose, and repair kits.

Image 3.1: An illustration detailing the components included with the EXTRAUP Water Transfer Pump, such as the pump unit, suction strainer, 6-foot suction hose, and repair kits.

4. Product Overview

Familiarize yourself with the main components of your water transfer pump:

  • Inlet Port: Where water enters the pump.
  • Outlet Port: Where water exits the pump.
  • Priming Port: Used to fill the pump head with water before operation.
  • Carry Handle: For easy portability.
  • Motor Housing: Protects the internal motor components.
  • Base: Provides stability during operation.
Close-up images highlighting the iron handle, strong base, and copper motor of the EXTRAUP water pump.

Image 4.1: Detailed views of the pump's robust features, including the durable iron handle for easy transport, the strong base ensuring stability, and the high-quality copper motor designed for long service life.

5. Setup & Installation

Follow these steps for initial setup:

  1. Positioning: Place the pump on a stable, dry, and level surface near the water source. Ensure it is not submerged.
  2. Connect Inlet Hose: Attach the supplied 6-foot inlet hose to the pump's inlet port (marked 'IN'). Ensure a tight, leak-free connection. If using the water suction attachment, connect it to the other end of the inlet hose and place it flatly and closely on the ground in the water source.
  3. Connect Outlet Hose: Attach your desired outlet hose (not included) to the pump's outlet port (marked 'OUT'). Ensure this connection is also tight and leak-free. Direct the outlet hose to the desired drainage or transfer location.
  4. Priming the Pump: Before first use, or if the pump has run dry, the pump head must be primed. Remove the priming plug (usually located on top of the pump head) and fill the pump head completely with clean water until it overflows. Replace the priming plug securely.
Detailed operating instructions showing how to prime the pump, connect hoses, and warnings against submersion and using dirty water.

Image 5.1: A comprehensive visual guide to the pump's operating instructions, illustrating the process of adding water to the inlet hole for priming, connecting inlet and outlet hoses, understanding the maximum vertical suction depth, and reiterating the importance of keeping the pump dry and using only clean water.

6. Operating Instructions

Once setup is complete, follow these steps to operate your pump:

  1. Ensure Priming: Confirm the pump head is fully primed with water.
  2. Power On: Plug the pump into a grounded 115V/60Hz electrical outlet. The pump will start immediately as it does not have an on/off switch.
  3. Monitor Operation: Observe the pump for proper water flow. The pump can remove water down to 1/8 inch with the suction attachment.
  4. Avoid Dry Running: Do not allow the pump to run dry for extended periods, as this can damage the impeller and motor. If the water source runs out, unplug the pump immediately.
  5. Power Off: To stop the pump, simply unplug it from the electrical outlet.

This pump is versatile and can be used for various applications:

  • Draining water beds, water heaters, and washing machines.
  • Filling radiant heating systems.
  • Draining small ponds, pools, or rain barrels.
  • Transferring water for gardening or aquariums.
Collage of images showing the water pump being used for various applications: aquariums, swimming pools, irrigation, rivers, and basements.

Image 6.1: A visual representation of the pump's multipurpose capabilities, demonstrating its effectiveness in draining aquariums, swimming pools, providing water for irrigation, drawing water from rivers, and removing water from basements.

7. Maintenance

Regular maintenance ensures the longevity and optimal performance of your pump:

  • Cleaning: After each use, especially if pumping from sources with potential sediment, flush the pump with clean water to prevent buildup.
  • Storage: Store the pump in a dry, protected area when not in use. In cold climates, ensure all water is drained from the pump to prevent freezing and cracking.
  • Impeller Replacement: The pump includes an impeller replacement kit. If you notice a significant drop in performance or unusual noises, the impeller may need to be inspected or replaced. Refer to the included diagram in the kit for specific instructions on how to access and replace the impeller.
  • Motor Brushes: As stated in general pump guidelines, motor brushes should be checked every 100 hours of use for wear.
Diagram showing the high-efficiency impeller and its replaceable nature within the pump's water flow.

Image 7.1: A close-up illustration of the pump's high-efficiency impeller, highlighting its design for optimal water transfer and its replaceable feature for extended pump life.

8. Troubleshooting

If you encounter issues with your pump, refer to the following common problems and solutions:

ProblemPossible CauseSolution
Pump runs but no water flows.Not primed; air lock; clogged inlet/outlet.Ensure pump is fully primed. Check for kinks or blockages in hoses.
Reduced water flow.Partial clog; worn impeller; air leak in inlet hose.Check and clear any clogs. Inspect impeller for wear. Ensure all connections are tight.
Pump does not start.No power; thermal overload activated; motor issue.Check power connection and circuit breaker. Allow pump to cool if overheated. Contact customer support if issue persists.
Pump is noisy.Dry running; foreign object in pump; worn bearings.Ensure pump is primed and has water flow. Disconnect power and inspect for debris.

9. Specifications

Key technical specifications for your EXTRAUP Water Transfer Pump:

  • Model: PAS-30A
  • Voltage: 115V / 60Hz
  • Horse Power: 1/10 HP
  • Maximum Flow Rate: 330 Gallons Per Hour (GPH) / 5.5 Gallons Per Minute (GPM)
  • Maximum Head Lift: 39 Feet
  • Low Suction Capability: Removes water down to 1/8 inch (with suction attachment)
  • Inlet/Outlet Size: 3/4" GHT (Garden Hose Thread)
  • Power Source: AC
  • Material: Stainless Steel (housing)
  • Item Weight: 5.41 Pounds
  • Product Dimensions: 8.9"L x 7.5"W x 9"H
Image showing the EXTRAUP water transfer pump with key specifications: 330 GPH Max Flow, 39 FT Max Head, and 1/10 HP Horsepower, operating near a pond.

Image 9.1: The EXTRAUP Water Transfer Pump in an outdoor setting, visually confirming its key performance metrics: 330 GPH maximum flow, 39 feet maximum head, and 1/10 horsepower.

10. Customer Support

EXTRAUP is committed to providing quality products and customer satisfaction. All pumps undergo 100% factory testing to ensure reliability.

If you have any questions, concerns, or require assistance with your EXTRAUP Water Transfer Pump, please do not hesitate to contact our customer support team. We are dedicated to providing you with a satisfactory answer and support for your daily use.

For the most up-to-date contact information, please refer to the official EXTRAUP website or the product packaging.

Thank you for choosing EXTRAUP.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.