PHILIPS 90561800

Philips HF-S 154 TL5 II Selectalume II Electronic Ballast User Manual

Model: 90561800

1. Introduction

This user manual provides essential information for the safe and efficient operation of your Philips HF-Selectalume II Electronic Ballast. The HF-Selectalume II ballast is a cost-effective, reliable, and energy-saving solution for fluorescent lighting systems. It features robust design and meets all relevant international safety and performance standards.

This ballast is designed for use in indoor luminaires such as spotlights, direct lighting (downlights), and recessed luminaires, commonly found in offices, shops, industries, hotels, restaurants, and other applications where control devices are used and on/off switching is occasional.

2. Safety Information

Please read all safety instructions carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or other hazards.

  • Electrical Hazard: Installation and maintenance should only be performed by qualified personnel. Disconnect power before servicing.
  • Proper Grounding: Ensure the ballast is properly grounded according to local electrical codes.
  • Operating Environment: Do not expose the ballast to moisture, extreme temperatures, or corrosive environments.
  • Compatibility: Use only with compatible fluorescent lamps as specified by Philips.
  • Ventilation: Ensure adequate ventilation around the ballast to prevent overheating.

3. Product Overview

The Philips HF-Selectalume II Electronic Ballast is designed to provide stable and efficient power to fluorescent lamps. Its compact design allows for easy integration into various lighting fixtures.

Philips HF-Selectalume II electronic ballast

An image showing the Philips HF-Selectalume II electronic ballast, a rectangular device with connection terminals visible at one end. The product label displays 'PHILIPS HF-Selectalume Electronic Ballast HF-S 235 TL5 II' along with electrical specifications like voltage (220-240V), frequency (50-60Hz), and power (2x35W).

Key Features:

  • Energy-saving technology
  • Robust and reliable design
  • Meets international safety and performance standards
  • Suitable for various indoor lighting applications
  • Quick preheat time (1.6 seconds)

4. Setup and Installation

Important: Installation must be performed by a qualified electrician and in accordance with all local and national electrical codes.

  1. Power Disconnection: Before starting any installation, ensure that the main power supply to the circuit is turned off at the breaker. Verify with a voltage tester.
  2. Mounting: Securely mount the ballast within the luminaire or enclosure using appropriate fasteners. Ensure proper air circulation around the ballast.
  3. Wiring:
    • Connect the input wires (Line, Neutral, Ground) from the power supply to the corresponding terminals on the ballast. Refer to the wiring diagram on the ballast label.
    • Connect the output wires from the ballast to the fluorescent lamp holders. Ensure correct polarity for each lamp.
    • Ensure all wire connections are secure and properly insulated.
  4. Lamp Insertion: Carefully insert the compatible fluorescent lamps into their respective lamp holders.
  5. Power Restoration: Once all connections are verified and secure, restore power to the circuit.

Refer to the wiring diagram printed on the ballast for specific connection details.

5. Operating Instructions

The Philips HF-Selectalume II Electronic Ballast operates automatically once properly installed and powered.

  • Power On/Off: The ballast will activate the lamps when power is supplied to the circuit. Use a wall switch or control system to turn the lighting fixture on or off.
  • Warm Start: This ballast features a warm start function, which preheats the lamp cathodes before ignition. This extends lamp life and ensures flicker-free starting. The preheat time is approximately 1.6 seconds.
  • Normal Operation: Once ignited, the ballast maintains stable lamp operation, providing consistent light output.

6. Maintenance

The Philips HF-Selectalume II Electronic Ballast is designed for long-term, maintenance-free operation. However, periodic checks of the lighting system are recommended.

  • Cleaning: Ensure the ballast and surrounding area are free from dust and debris to maintain proper heat dissipation. Use a dry, soft cloth for cleaning. Do not use liquid cleaners.
  • Lamp Replacement: When replacing lamps, always turn off the power supply to the fixture first. Replace lamps with the same type and wattage as specified for the ballast.
  • Inspection: Periodically inspect wiring for any signs of wear, damage, or loose connections.
  • Professional Service: If the ballast malfunctions or shows signs of damage, do not attempt to repair it yourself. Contact a qualified electrician or Philips customer support.

7. Troubleshooting

If you experience issues with your Philips HF-Selectalume II Electronic Ballast, refer to the following common problems and solutions:

Problem Possible Cause Solution
Lamps do not light up. No power supply, faulty lamp, incorrect wiring, faulty ballast. Check power supply and circuit breaker. Replace lamp. Verify wiring connections. If problem persists, ballast may need replacement.
Lamps flicker or dim. Incorrect lamp type, aging lamp, unstable power supply, ballast nearing end of life. Ensure correct lamp type is used. Replace lamp. Check power quality. Consider ballast replacement if issues continue.
Ballast makes unusual noise. Loose mounting, internal component issue. Ensure ballast is securely mounted. If noise persists, disconnect power and contact a qualified electrician.
Overheating. Insufficient ventilation, operating outside specified temperature range. Ensure adequate airflow around the ballast. Check ambient temperature.

For issues not listed above, or if troubleshooting steps do not resolve the problem, contact Philips customer support or a qualified electrician.

8. Specifications

Technical specifications for the Philips HF-S 154 TL5 II Selectalume II Electronic Ballast (Model: 90561800):

Attribute Value
Manufacturer Philips Lighting B.V.
Model Number 90561800
Part Number 90561800
Application Code II
Type MK1
Preheat Time 1.6 s
Input Voltage 220-240V
Frequency 50/60Hz
Output Power 2x35W (for TL5 lamps)
Item Weight 185 g
Package Dimensions 28 x 3 x 2.1 cm
Batteries Required No
Contents 1 x Selectalume Electronic Ballast

9. Warranty and Support

Philips products are manufactured to the highest quality standards. For information regarding warranty coverage, please refer to the warranty card included with your product or visit the official Philips website.

For technical support, troubleshooting assistance, or to inquire about replacement parts, please contact Philips customer service. Contact details can typically be found on the Philips official website or on your product packaging.

Online Resources: For additional information and support, visit the official PHILIPS Store on Amazon or the main Philips website.

© 2024 Philips. All rights reserved.

This manual is subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.