1. Product Overview
This document provides instructions for the S-Union 240W Power Supply Unit (PSU), designed as a replacement for specific Dell OptiPlex Small Form Factor (SFF) desktop systems. This PSU delivers a maximum output of 240W and is engineered for stable performance and compatibility with the listed Dell models.

Image 1.1: S-Union 240W Power Supply Unit highlighting stable performance, high-quality materials, premium temperature-controlled fan, and large-area mesh for heat dissipation.
2. Compatibility
This S-Union 240W Power Supply Unit is specifically designed for Dell OptiPlex Small Form Factor (SFF) systems. It is crucial to verify your system's form factor before installation. This PSU is not compatible with Dell Mini Tower (MT), Desktop (DT), or Ultra Small Form Factor (USFF) systems.
2.1 Compatible Dell OptiPlex SFF Models:
- Dell OptiPlex 390 SFF
- Dell OptiPlex 790 SFF
- Dell OptiPlex 960 SFF
- Dell OptiPlex 990 SFF
- Dell OptiPlex 3010 SFF
- Dell OptiPlex 7010 SFF
- Dell OptiPlex 9010 SFF
2.2 Compatible Model Numbers:
- H240AS-00, H240AS-01
- H240ES-00, H240ES-01
- AC240AS-00, AC240AS-01
- L240AS-00, L240AS-01
- AC240ES-00, AC240ES-01
- D240ES-00, D240ES-01
- DPS-240WB
2.3 Compatible Part Numbers:
- 3WN11, 709MT, 592JG, 66VFV
- CCCVC, RV1C4, J50TW, 2TXYM

Image 2.1: Diagram illustrating compatibility with Dell OptiPlex Small Form Factor (SFF) systems, explicitly showing incompatibility with USFF, DT, and MT form factors.
3. Specifications
| Feature | Specification |
|---|---|
| Model Name | ATX Power Supply |
| Input Voltage | 100-240V / 4A (50-60Hz) |
| Max Output Power | 240W |
| Form Factor | ATX (Small Form Factor specific) |
| Cooling Method | Air |
| Dimensions (L x W x H) | 9.9 x 3.6 x 4.4 inches (approx. 25.1 x 9.1 x 11.2 cm) |
| Item Weight | 2.02 pounds (approx. 0.92 kg) |
| Connectors | P1: 24-Pin ATX Power (3 inch) P2: 4-Pin ATX Power (18.9 inch) P3: SATA Power (5.5 inch) P4: SATA Power (7.48 inch) P5: 2-Pin Slim Line SATA (6.1 inch) |

Image 3.1: Visual representation of the S-Union 240W Power Supply Unit's dimensions and connector types with their approximate cable lengths.

Image 3.2: Close-up of the power supply unit's label, showing model number H240AS-00, input/output specifications, and maximum output power of 240W.
4. Installation Guide
Replacing a power supply unit requires careful handling of computer components. If you are unsure about any step, consult a qualified technician or refer to online resources for visual guidance.
4.1 Safety Precautions:
- Always unplug the computer from the wall outlet before opening the case.
- Disconnect all peripheral cables (monitor, keyboard, mouse, etc.).
- Bring the computer to a well-lit, clean, and comfortable work surface.
- Ground yourself by touching a metal object (like a screw on a light switch plate) before touching any internal components to discharge static electricity, which can damage sensitive electronics.
4.2 Step-by-Step Installation:
- Document Connections: Before disconnecting anything, take clear pictures of all cable connections, especially those to the motherboard and drives. This will serve as a reference during reassembly.
- Open Computer Case: Remove the side panel of your Dell OptiPlex SFF system to access the internal components.
- Disconnect Old Power Supply: Carefully disconnect all power cables from the motherboard (24-pin ATX, 4-pin ATX), SATA drives, and any other components powered by the old PSU. Pull connectors straight out; avoid pulling on the wires. Some connectors may have clips that need to be pressed or squeezed.
- Remove Old Power Supply: Locate and remove the screws securing the old power supply to the computer chassis, typically at the back of the case. Slide or unlatch any retention mechanisms holding the PSU in place and carefully remove it from the case.
- Install New Power Supply: Position the new S-Union 240W PSU into the vacant slot. Ensure it aligns correctly with the screw holes. Secure the new PSU with the screws previously removed.
- Connect Cables: Refer to your earlier photographs and connect the new PSU's cables to the appropriate components:
- Connect the 24-pin ATX power connector to the motherboard.
- Connect the 4-pin ATX power connector to the motherboard.
- Connect SATA power connectors to your hard drives and optical drives.
- Ensure all connections are firm and correctly oriented.
- Manage Cables: Route cables neatly to avoid obstructing airflow or interfering with other components.
- Close Case: Replace the computer's side panel and secure it.
- Final Connections: Reconnect all external peripherals and the power cord to the computer.
For visual assistance, you may search for installation videos specific to your Dell OptiPlex SFF model on platforms like YouTube. Search terms such as "Dell OptiPlex [Your Model] SFF PSU replacement" can be helpful.
Video 4.1: An official S-Union video demonstrating the installation process for the H240AS-00 240W Power Supply Unit in a Dell OptiPlex SFF system.
5. Operating
Once the S-Union 240W Power Supply Unit is correctly installed and all connections are secure, the unit operates automatically upon powering on your computer. The PSU provides the necessary electrical power to all internal components of your Dell OptiPlex SFF system.
- Ensure the power cable is securely connected to both the PSU and a functional wall outlet or surge protector.
- Press the power button on your Dell OptiPlex system. The PSU will initiate power delivery.
6. Maintenance
The S-Union 240W Power Supply Unit is designed for reliable operation with minimal maintenance. However, adhering to general computer maintenance practices can prolong its lifespan and ensure optimal performance:
- Keep Clean: Periodically clean the exterior of your computer case to prevent dust buildup, especially around ventilation areas. Dust can impede airflow and cause components, including the PSU, to overheat.
- Ensure Airflow: Do not block the ventilation openings of your computer case. Ensure the computer is placed in an area with adequate air circulation.
- Stable Power Source: Connect your computer to a reliable power source, preferably through a surge protector or Uninterruptible Power Supply (UPS), to protect against power fluctuations.
7. Troubleshooting
If your computer fails to power on or experiences power-related issues after installing the new PSU, consider the following troubleshooting steps:
- No Power / No Lights / No Fan:
- Verify that the power cable is securely plugged into both the PSU and the wall outlet/surge protector.
- Ensure the wall outlet or surge protector is functional by testing it with another device.
- Double-check all internal power connections from the PSU to the motherboard (24-pin and 4-pin ATX) and all drives. Ensure they are fully seated.
- Confirm that the power supply's input voltage switch (if present) is set correctly for your region (e.g., 115V for North America, 230V for Europe).
- Ensure the computer's power button is functioning correctly.
- Intermittent Power / System Instability:
- Check for loose internal power connections.
- Ensure adequate ventilation to prevent overheating, which can cause system instability.
- If possible, test the PSU with a power supply tester to verify voltage outputs.
- Incorrect Form Factor:
Confirm that your Dell OptiPlex system is indeed a Small Form Factor (SFF) model. This PSU is not compatible with MT, DT, or USFF systems, and attempting to install it in an incompatible system may lead to issues or damage.
If issues persist after performing these checks, it may indicate a problem with another component of your computer or require professional assistance.
8. Quality Assurance, Warranty, and Support
Each S-Union power supply unit undergoes strict quality control measures before shipment to ensure reliability and performance.
8.1 Quality Testing:
All power supply units are subjected to comprehensive testing, including high and low voltage tests, aging tests, and load tests (power, voltage, current) to meet quality standards.

Image 8.1: Visual representation of the quality assurance process, including Chroma Testing, Load Testing, and Aging Tests performed on the power supply units.
8.2 Warranty and Customer Support:
S-Union provides an 18-month worry-free warranty for this product. If you encounter any issues or are not completely satisfied, you may request a replacement or a full refund.
For any pre-sale or after-sale questions, please contact S-Union customer service. Our team aims to provide a satisfactory answer within 24 hours.