1. Introduction

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your ALEKO COASTS KSA60M Steam Generator. Please read this manual thoroughly before installation and use, and keep it for future reference. Proper adherence to these instructions will ensure the longevity and optimal performance of your steam generator.

2. Safety Information

WARNING: Failure to follow these safety instructions may result in electric shock, fire, serious injury, or death. Always consult with a qualified electrician and plumber for installation.

  • Electrical Hazard: Ensure the main power supply is turned OFF before attempting any installation, maintenance, or troubleshooting. This unit operates on 220-240V, 2 phase wiring, 60Hz. All electrical connections must comply with local and national electrical codes.
  • Water Connections: Ensure all water connections are secure and leak-free. Install the provided 10 PSI pressure relief valve as instructed. Do not install any valve in the steam outlet line.
  • Installation Location: Install the steam generator in a dry, well-ventilated area, protected from freezing temperatures. Ensure adequate clearance around the unit for ventilation and service access.
  • Children and Pets: Keep children and pets away from the steam generator and steam room during operation.
  • Hot Surfaces: The steam outlet and steam head will become very hot during operation. Avoid direct contact.
  • Professional Installation: It is highly recommended that installation be performed by a licensed professional to ensure safety and compliance with all applicable codes.

3. Product Overview

The ALEKO COASTS KSA60M Steam Generator is a robust and reliable unit designed to provide a consistent steam supply for your sauna. It features a durable stainless steel construction, a 6 kW heating capacity, and is controlled by the included KS-150 digital controller. The unit is equipped with three 2.0 kW heating elements for efficient steam production and includes an automatic drain function.

ALEKO COASTS KSA60M Steam Generator with KS-150 Controller and accessories

Figure 3.1: Complete ALEKO COASTS KSA60M Steam Generator package, including the main unit, KS-150 digital controller, steam head, and pressure relief valve.

KS-150 Digital Controller and Steam Head

Figure 3.2: Close-up view of the KS-150 digital controller and the steam head, which are key components for operating and delivering steam to your sauna.

4. Setup and Installation

Proper installation is critical for the safe and effective operation of your steam generator. Refer to the detailed installation diagrams and instructions provided in the separate installation guide included with your product. Below are general guidelines and component identification.

4.1 Component Identification

Side view of ALEKO COASTS Steam Generator showing connection ports

Figure 4.1: Side view of the steam generator, highlighting the Steam Outlet, Pressure Relief Valve port, Drain, and Water Inlet connections. Note the caution label regarding electrical shock.

  • Steam Outlet: Connects to the steam line leading to the steam room. No valve should be installed in this line.
  • Pressure Relief Valve: Install the provided 10 PSI valve here. This is a critical safety component.
  • Water Inlet: Connects to the cold water supply. Use two wrenches to avoid damage during connection.
  • Drain: Connects to a suitable drain line. The unit features an automatic drain function.
  • Electrical Connection: Located on the side/rear of the unit. Requires 220-240V, 2 phase wiring.
  • KS-150 Controller Port: Connects the digital controller to the main unit.

4.2 Key Components

Pressure Relief Valve

Figure 4.2: The pressure relief valve, essential for safety, designed to release pressure if it exceeds 1.5 bar (approximately 21.75 PSI).

Steam Head Components

Figure 4.3: Components of the steam head, which disperses steam into the sauna room.

Heating Element

Figure 4.4: One of the three 2.0 kW heating elements responsible for boiling water to produce steam.

Temperature Sensor

Figure 4.5: The temperature sensor, which monitors the steam room temperature for accurate control.

Controller Cable

Figure 4.6: The cable connecting the KS-150 controller to the steam generator unit.

5. Operating Instructions

The KS-150 controller provides intuitive control over your steam generator's functions.

5.1 KS-150 Controller Functions

  • Power On/Off: Use the designated button to turn the steam generator on or off.
  • Temperature Control: Adjust the desired steam room temperature using the up/down arrows. The controlling temperature range is 95 to 131 Fahrenheit (35 to 55 Celsius).
  • Time Setting: Set the desired operating time for the steam session. The controlling time range is 1 to 60 minutes.
  • Automatic Drain: The unit features an automatic drain function, which will activate after each session or when manually initiated, to prevent mineral buildup.
  • Light Control: If connected, the controller may also manage steam room lighting.

Once the desired temperature and time are set, the generator will begin heating. Steam production will start once the water reaches the boiling point.

6. Maintenance

Regular maintenance ensures the longevity and efficient operation of your ALEKO COASTS KSA60M Steam Generator. Always disconnect power before performing any maintenance.

  • Descaling: Over time, mineral deposits can accumulate inside the generator. Regular descaling is recommended, especially in areas with hard water. Refer to the separate maintenance guide for detailed descaling procedures. The automatic drain helps reduce mineral buildup.
  • Cleaning: Periodically wipe down the exterior of the unit with a damp cloth. Do not use abrasive cleaners.
  • Inspect Connections: Annually inspect all water and electrical connections for any signs of leaks, corrosion, or wear.
  • Pressure Relief Valve: Periodically check the pressure relief valve to ensure it is not obstructed and functions correctly.

7. Troubleshooting

If you encounter issues with your steam generator, refer to the following common troubleshooting steps. For problems not listed here, contact customer support.

ProblemPossible CauseSolution
No steam productionNo power; Water supply off; Controller not set; Heating elements faulty.Check power breaker; Ensure water supply is open; Verify controller settings (time/temp); Contact support if elements are suspected.
Insufficient steamLow water pressure; Mineral buildup; Steam room not sealed.Check water pressure; Perform descaling; Ensure steam room is properly sealed.
Unit not heatingPower issue; Controller error; Overheat protection activated.Check power supply; Reset controller; Allow unit to cool down if overheat protection is active.
Water leakingLoose connections; Damaged pipes/fittings.Tighten all water connections; Inspect pipes and fittings for damage and replace if necessary.

8. Specifications

AttributeDetail
Model NumberKSA60M
Power6 KW
Voltage220-240V, 2 phase wiring, 60Hz
Heating Elements3 x 2.0 KW
Controlling Time Range1 to 60 minutes
Controlling Temperature Range95 to 131 Fahrenheit (35 to 55 Celsius)
Product Dimensions19 x 17 x 8 inches
Item Weight21 pounds
ManufacturerCoasts
ASINB06X1CLNKY

9. Warranty and Support

For specific warranty information regarding your ALEKO COASTS KSA60M Steam Generator, please refer to the warranty card included with your purchase or contact ALEKO customer support directly. Warranty terms and conditions may vary.

If you require technical assistance, have questions about installation, operation, or maintenance, please contact ALEKO customer support through their official website or the contact information provided with your product documentation.

Note: No official product videos from the seller were found to be included in this manual.

© 2024 ALEKO. All rights reserved.

Ask a question about this manual