CANNON Instrument 9727-N37.032 Cold-Cranking Simulator Standard Instruction Manual

Model: 9727-N37.032

1. Product Overview

The CANNON Instrument 9727-N37.032 Cold-Cranking Simulator Standard, designated as CL300, is a certified reference material designed for the precise calibration and verification of various viscometer types. This includes glass capillary viscometers, rotational viscometers, falling ball viscometers, and cup viscometers. Its formulation ensures compliance with critical industry standards such as ASTM D 5293 and SAE Specification J300, making it essential for accurate viscosity measurements in laboratory and industrial settings.

Assortment of CANNON Instrument calibration standards in various bottle sizes.

This image displays a collection of CANNON Instrument calibration standards, packaged in different amber glass bottles and a metal container, indicating various volumes and types of reference materials for laboratory use.

2. What's in the Box

Upon receiving your CANNON Instrument 9727-N37.032 Cold-Cranking Simulator Standard, please verify that the following item is present:

  • One (1) 1L bottle of CANNON Instrument 9727-N37.032 Cold-Cranking Simulator Standard (CL300)

3. Setup and Preparation

  1. Inspection: Upon receipt, inspect the standard bottle for any signs of damage or leakage. Ensure the seal is intact.
  2. Temperature Equilibration: Allow the standard to equilibrate to the desired test temperature for at least 2 hours before use. This is crucial for accurate viscosity measurements.
  3. Mixing: Gently invert the bottle several times to ensure homogeneity before opening. Avoid vigorous shaking, which can introduce air bubbles.
  4. Cleanliness: Ensure all glassware and equipment coming into contact with the standard are clean and dry to prevent contamination.

4. Operating Instructions

Follow these general guidelines when using the Cold-Cranking Simulator Standard for calibration or verification:

  1. Refer to Viscometer Manual: Always consult the specific operating manual for your viscometer instrument for detailed instructions on calibration and sample introduction.
  2. Sample Introduction: Carefully pour the required amount of standard into the viscometer cell or tube, avoiding air bubbles.
  3. Temperature Control: Maintain the specified test temperature precisely throughout the measurement process.
  4. Measurement: Perform viscosity measurements according to your viscometer's protocol. Take multiple readings to ensure reproducibility.
  5. Documentation: Record all measurement data, including temperature, standard lot number, and instrument readings, for traceability.

5. Maintenance

Proper handling and storage are key to maintaining the integrity of your standard:

  • Cap Tightly: After each use, immediately recap the bottle tightly to prevent evaporation and contamination.
  • Avoid Contamination: Never return used standard to the original bottle. Always use clean pipettes or pouring techniques.
  • Storage: Store the standard in its original container in a cool, dark place, away from direct sunlight and heat sources. Refer to the product label for specific storage temperature ranges.

6. Troubleshooting

If you encounter issues during calibration or verification, consider the following:

  • Inconsistent Readings: Ensure the standard has fully equilibrated to the test temperature. Check for air bubbles in the sample or viscometer. Verify instrument calibration.
  • Readings Outside Expected Range: Confirm the correct standard is being used for the application. Check the expiration date of the standard. Ensure the viscometer is functioning correctly and has been recently calibrated.
  • Contamination: If contamination is suspected, discard the affected portion of the standard and use a fresh aliquot. Clean all equipment thoroughly.

7. Specifications

AttributeDetail
Model Number9727-N37.032
Product DescriptionCold-Cranking Simulator Standard, CL300
Volume1 Liter
ManufacturerCANNON Instrument
ComplianceASTM D 5293, SAE Specification J300
Product Dimensions8 x 8 x 10 inches
ASINB01MYVPA69

8. Safety Information

This product is a chemical standard. Always handle with care and observe standard laboratory safety procedures:

  • Personal Protective Equipment (PPE): Wear appropriate PPE, including safety glasses, gloves, and a lab coat, when handling the standard.
  • Ventilation: Use in a well-ventilated area or under a fume hood to avoid inhalation of vapors.
  • Skin and Eye Contact: Avoid direct contact with skin and eyes. In case of contact, flush immediately with plenty of water and seek medical attention if irritation persists.
  • Ingestion: Do not ingest. If swallowed, seek immediate medical attention.
  • Flammability: Refer to the Safety Data Sheet (SDS) for specific flammability information and handling precautions. Keep away from open flames and ignition sources.
  • SDS: Always consult the product's Safety Data Sheet (SDS) for comprehensive safety information before use.

9. Storage and Handling

To maintain the stability and accuracy of the standard, adhere to the following storage and handling guidelines:

  • Original Container: Store the standard in its original, tightly sealed container.
  • Temperature: Store in a cool, dry place, typically between 15°C and 25°C (59°F and 77°F), unless otherwise specified on the product label.
  • Light Protection: Protect from direct sunlight and strong artificial light.
  • Away from Contaminants: Store away from incompatible materials, strong acids, bases, and oxidizing agents.
  • Shelf Life: Observe the expiration date printed on the product label. Do not use expired standards.

10. Disposal

Dispose of used or expired standards in accordance with all local, regional, and national environmental regulations. Do not pour down drains or dispose of with general waste. Consult your facility's waste management procedures or a licensed waste disposal contractor.

11. Contact Information

For technical support, inquiries, or further information regarding the CANNON Instrument 9727-N37.032 Cold-Cranking Simulator Standard, please contact:

CANNON Instrument Company

Manufacturer: Cannon Instrument

Website: www.cannoninstrument.com

Please refer to the official CANNON Instrument website for the most current contact details and support resources.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.