Origin Battery PST PA350-120U

Instruction Manual

Liebert PowerSure PST PA350-120U Battery Replacement Kit

Brand: Origin Battery

Product Overview

This kit provides a replacement battery for the Liebert PowerSure PST PA350-120U Uninterruptible Power Supply (UPS). It includes one (1) 12V 5Ah sealed lead acid (SLA) battery, specifically designed to meet or exceed the original equipment manufacturer (OEM) specifications for the OR-1250 battery. These are high-rate (HR) series AGM (Absorbent Glass Mat) SLAs, rigorously tested to ensure optimal performance and compatibility.

Origin Battery OR-1250HR 12V 5AH Sealed Lead Acid Battery

Figure 1: The Origin Battery OR-1250HR 12V 5AH Sealed Lead Acid Battery, the primary component of the replacement kit. This image shows the battery's green body, blue top, and red and blue terminals, along with branding and specifications.

Safety Information

Always prioritize safety when handling batteries. Improper handling can lead to electric shock, burns, or fire. Read and understand all instructions before proceeding with battery replacement.

  • Wear appropriate personal protective equipment (PPE), such as insulated gloves and eye protection.
  • Ensure the UPS unit is completely powered off and disconnected from the AC power source before beginning any work.
  • Avoid short-circuiting the battery terminals.
  • Do not dispose of batteries in fire.
  • Recycle used batteries according to local regulations.

Setup and Installation

This section outlines the steps for replacing the battery in your Liebert PowerSure PST PA350-120U UPS. Refer to your UPS's specific manual for detailed instructions on accessing the battery compartment.

  1. Prepare the UPS: Power off the Liebert PowerSure PST PA350-120U UPS and unplug it from the wall outlet. Disconnect all connected devices.
  2. Access Battery Compartment: Locate and open the battery compartment of your UPS. This usually involves removing screws or sliding a cover.
  3. Disconnect Old Battery: Carefully disconnect the terminals of the old battery. Note the polarity (positive and negative) before disconnecting. Typically, red is positive (+) and black is negative (-). Disconnect the negative terminal first, then the positive.
  4. Remove Old Battery: Gently remove the old battery from the compartment.
  5. Inspect New Battery: Before installation, inspect the new Origin Battery OR-1250HR for any visible damage.
  6. Connect New Battery: Connect the new battery. Connect the positive terminal first (red wire to red terminal), then the negative terminal (black wire to blue terminal). Ensure connections are secure.
  7. Close-up of F2 battery terminals

    Figure 2: A close-up view of the F2 terminals on the battery. The wider, spade-like terminal is the F2 type, designed for secure connections in UPS systems.

  8. Secure Battery: Place the new battery securely within the compartment.
  9. Close Compartment: Close and secure the battery compartment cover.
  10. Reconnect UPS: Plug the UPS back into the wall outlet and reconnect your devices.
  11. Initial Charge: Allow the UPS to charge the new battery for at least 8-12 hours before relying on it for backup power.

Operating Characteristics

The OR-1250HR battery is a sealed lead acid battery designed for standby power applications, such as in UPS systems. It is a valve-regulated, rechargeable battery.

  • Constant Voltage Charge:
    • Cycle Use: 14.4-15.0V
    • Standby Use: 13.5-13.8V
  • Initial Current: Less than 1.5A
  • Recharge: Always recharge the battery after use to maintain its lifespan and performance.

Maintenance

Sealed Lead Acid (SLA) batteries are generally maintenance-free. However, following these guidelines can help prolong battery life:

  • Temperature: Store and operate the battery within recommended temperature ranges (typically 20-25°C or 68-77°F) to maximize lifespan. Extreme temperatures can degrade performance.
  • Charging: Ensure the UPS unit provides a consistent and appropriate charging voltage. Overcharging or undercharging can damage the battery.
  • Cleaning: Keep battery terminals clean and free of corrosion. Use a dry cloth to wipe down the battery if necessary.
  • Storage: If storing the battery for an extended period, ensure it is fully charged and recharge it periodically (e.g., every 3-6 months) to prevent deep discharge.

Troubleshooting

If your UPS does not function correctly after battery replacement, consider the following:

  • No Power/UPS Not Turning On:
    • Verify that the UPS is plugged into a live AC outlet.
    • Check all battery connections to ensure they are secure and correctly polarized (positive to positive, negative to negative).
    • Allow the battery to charge for several hours. A completely discharged new battery may require an initial charge before the UPS can power on.
    • Ensure the UPS's power button is pressed correctly.
  • Short Runtime:
    • The battery may not be fully charged. Allow more charging time.
    • The load connected to the UPS might exceed its capacity. Reduce the connected load.
    • Battery life can be affected by operating temperature. Ensure adequate ventilation around the UPS.
  • Unusual Odor or Swelling:
    • Immediately disconnect the UPS from power and discontinue use. This indicates a serious battery issue. Contact the manufacturer or a qualified technician.

Specifications

AttributeDetail
Battery TypeSealed Lead Acid (SLA), AGM HR Series
Voltage12V
Capacity5Ah
Model NumberOR-1250HR
Dimensions (L x W x H)3.54″ x 2.76″ x 3.09″
Terminal TypeF2
CertificationsDOT, IATA, FAA, CAB certified; UL recognized (MH 20845); CE certified

Warranty Information

This Origin Battery replacement kit comes with a Two-Year Warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use. Please retain your proof of purchase for warranty claims. For specific warranty terms and conditions, refer to the manufacturer's official documentation or contact their customer support.

Support

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact Origin Battery customer support. Refer to the packaging or the Origin Battery website for the most current contact information.

Website: www.OriginBattery.com

© 2024 Origin Battery. All rights reserved.