PM6860DR

PEAKMETER PM6860DR 230V Automatic Electric Socket Tester Instruction Manual

1. Introduction

The PEAKMETER PM6860DR is an automatic electric socket tester designed to quickly verify the correct wiring connection of a socket. It identifies whether neutral, live, and earth wires are correctly connected and indicates if any wire is missing. This device also includes an RCD (Residual Current Device) test function for enhanced safety verification. Its compact size and lightweight design make it a practical diagnostic tool for 230V electrical systems.

Angled view of the PEAKMETER PM6860DR 230V Automatic Electric Socket Tester with an EU plug.

Figure 1: Angled view of the PEAKMETER PM6860DR 230V Automatic Electric Socket Tester with an EU plug.

2. Safety Information

  • This device is designed for 230V electrical systems only. Do not use it with other voltage systems.
  • Always ensure the socket tester is in good condition before use. Do not use if the casing is damaged.
  • Do not attempt to open or modify the device. There are no user-serviceable parts inside.
  • The RCD test function should only be performed by a competent person. It will trip the RCD, interrupting power to the circuit.
  • If the tester indicates a wiring fault, consult a qualified electrician immediately. Do not use the socket until the fault is corrected.
  • Keep out of reach of children.

3. Product Features

  • Rapidly detects correct socket wiring.
  • Identifies missing neutral, live, and earth wire connections.
  • Includes RCD test function for additional safety checks.
  • Clear indicator lights for easy fault diagnosis.
  • Compact and lightweight design for portability.

4. Setup

The PEAKMETER PM6860DR socket tester is ready for use out of the box. No batteries or complex assembly are required as it draws power directly from the socket being tested. Ensure you have the correct plug type (EU, UK, or US) for your region.

Three versions of the PEAKMETER PM6860DR socket tester, showing EU, UK, and US plug types.

Figure 2: The PEAKMETER PM6860DR is available with EU, UK, or US plug types.

5. Operating Instructions

5.1. Wiring Test

  1. Plug the PEAKMETER PM6860DR directly into the 230V socket you wish to test.
  2. Observe the indicator lights on the front panel of the tester.
  3. Refer to the indicator light pattern table below to determine the wiring status of the socket.
Front view of the PEAKMETER PM6860DR socket tester showing the indicator lights and wiring fault labels.

Figure 3: Front panel of the PEAKMETER PM6860DR showing indicator lights and fault descriptions.

5.2. Indicator Light Patterns

Indicator Lights (Left to Right)StatusDescription
CORRECTThe socket is wired correctly.
MISSING EARTHThe earth wire is not connected. This is a serious fault.
LIVE EARTH REVERSEThe live and earth wires are reversed. This is a dangerous fault.
LIVE NEUTRAL REVERSEThe live and neutral wires are reversed.
MISSING NEUTRALThe neutral wire is not connected.

Note: This unit will not detect Earth Neutral Reverse.

5.3. RCD Test

  1. Ensure the socket is wired correctly according to the wiring test (all green lights for 'CORRECT').
  2. Press the RCD test button located on the side of the tester.
  3. A functional RCD should trip, cutting power to the circuit. If the RCD does not trip, it indicates a fault with the RCD or the wiring.
  4. Reset the RCD after testing.
Side view of the PEAKMETER PM6860DR socket tester highlighting the RCD test button.

Figure 4: Side view of the PEAKMETER PM6860DR showing the RCD test button.

6. Maintenance

  • Clean the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Store the tester in a dry environment, away from direct sunlight and extreme temperatures.
  • Inspect the plug pins and casing for any damage before each use.

7. Troubleshooting

  • No lights illuminate when plugged in: Ensure the socket has power. Check the circuit breaker. If the socket has power and no lights illuminate, the tester may be faulty or the wiring issue is severe (e.g., no live connection).
  • RCD does not trip during test: This indicates a potential fault with the RCD itself or the electrical installation. Do not rely on this RCD for protection and consult a qualified electrician immediately.
  • Inconsistent readings: Ensure the tester is fully inserted into the socket. Test multiple sockets to confirm consistent behavior.

8. Specifications

SpecificationValue
ModelPM6860DR
Voltage230V (EU)
Frequency50-60Hz
RCD Test Current30mA
Item Size6 x 6.5 x 6 cm / 2.36 x 2.56 x 2.36 in
Item Weight48-59g / 1.69-2.08oz
Power Source TypeCorded Electric
Batteries IncludedNo

9. Warranty and Support

For warranty information or technical support, please refer to the documentation provided at the time of purchase or contact the retailer/manufacturer directly. Keep your purchase receipt as proof of purchase.

Documents - PM6860DR – PM6860DR
[pdf] Document
Produkt shopGold PM6860DR tester PeakMeter 220 250V AC gotronikPM6860DR produkcji to wtyczkowy poprawności podłaczenia do gniazdka lini elektrycznych L N i uziemienia przewodu zerującegopm6860dr peakmeter 250v acgotronik pl pm6860dr ac karta 4126 html |||
Dane aktualne na dzie : 27-01-2026 10:40 Link do produktu: https://www.gotronik.pl/pm6860dr-tester-peakmeter-220-250v-ac-p-4126.html PM6860DR tester PeakMeter 220-250V AC Cena brutto Cena netto Dost pno Czas wysy ki Numer katalogowy 53,09 z 43,16 z Wkr tce dost pny 24 godziny BTE-486...
score:54 filesize: 207.05 K page_count: 1 document date: 2026-01-27
[pdf] Datasheet
PM6860 1 jpg I M Тестер за контакти SCHUKO PM6860DR PEAKMETER 3346 342582 pm6860d panda bg datasheet |||
...
score:19 filesize: 553.77 K page_count: 1 document date: 2023-06-21