1. Introduction

This manual provides essential information for the proper use, setup, operation, and maintenance of your A&D HL-3000WPN HL-WP Series Washdown Compact Scale. Please read this manual thoroughly before using the scale to ensure correct operation and to prevent damage.

2. Safety Precautions

  • Do not disassemble or modify the scale. This may cause damage or malfunction.
  • Avoid exposing the scale to extreme temperatures, direct sunlight, or high humidity.
  • Ensure the scale is placed on a stable, level surface to obtain accurate measurements.
  • Do not overload the scale beyond its maximum capacity of 3000g (6.6 lb).
  • Clean the scale with a damp cloth and mild detergent. Do not use abrasive cleaners or solvents.

3. Product Overview

The A&D HL-3000WPN is a compact, washdown-capable digital scale designed for various weighing applications. Its stainless steel construction ensures durability and ease of cleaning.

A&D HL-3000WPN HL-WP Series Washdown Compact Scale

Figure 3.1: A&D HL-3000WPN HL-WP Series Washdown Compact Scale. This image shows the stainless steel scale with its digital display and control buttons. The display reads '0.0 oz', and the buttons are labeled 'ON/OFF', 'RE-ZERO', and 'UNITS'. Indicators for 'STABLE' and 'ZERO' are also visible.

Key Components:

  • Weighing Pan: Stainless steel platform for placing items.
  • Display: Digital LCD showing weight readings and status indicators.
  • ON/OFF Button: Powers the scale on or off.
  • RE-ZERO Button: Resets the display to zero (tare function).
  • UNITS Button: Toggles between available weighing units (g, lb, oz).
  • STABLE Indicator: Lights up when the weight reading is stable.
  • ZERO Indicator: Lights up when the display is at zero.

4. Setup

4.1 Unpacking

  1. Carefully remove the scale and all accessories from the packaging.
  2. Check for any visible damage. If damage is found, contact your supplier immediately.
  3. Retain the packaging for future transport or storage.

4.2 Power Supply

The HL-3000WPN scale operates on AC adapter (not included) or batteries (not included). Ensure the correct power source is used as specified by the manufacturer.

4.3 Placement

  • Place the scale on a firm, level, and vibration-free surface.
  • Avoid locations with direct sunlight, rapid temperature changes, or strong air currents (e.g., near air conditioning vents).
  • Ensure sufficient space around the scale for proper operation and cleaning.

5. Operating Instructions

5.1 Basic Weighing

  1. Press the ON/OFF button to turn on the scale. The display will show '0.0' or '0.00' after a brief self-test.
  2. Ensure the display reads zero before placing an item on the weighing pan. If not, press the RE-ZERO button.
  3. Gently place the item to be weighed on the center of the weighing pan.
  4. Wait for the STABLE indicator to light up. Read the weight displayed.
  5. Remove the item from the pan.

5.2 Changing Weighing Units

To switch between available weighing units (grams, pounds, ounces):

  • With the scale on, press the UNITS button.
  • Each press will cycle through the available units (e.g., g → lb → oz → g).
  • Select the desired unit for your measurement.

5.3 Tare Function (RE-ZERO)

The tare function allows you to weigh items in a container by subtracting the container's weight:

  1. Place the empty container on the weighing pan.
  2. Wait for the weight reading to stabilize.
  3. Press the RE-ZERO button. The display will return to zero, and the ZERO indicator will light up.
  4. Place the item to be weighed into the container. The display will show the net weight of the item.

6. Maintenance

6.1 Cleaning

  • Regularly clean the weighing pan and the scale body.
  • Use a soft cloth dampened with water and a mild, non-abrasive detergent.
  • For washdown, ensure all covers are properly sealed. Do not use high-pressure water jets directly on the display or buttons.
  • Dry the scale thoroughly after cleaning.

6.2 Storage

  • When not in use for extended periods, store the scale in a dry, cool place.
  • If using batteries, remove them before long-term storage to prevent leakage.

6.3 Calibration

The scale is factory calibrated. If you suspect accuracy issues, refer to the full technical manual or contact A&D Medical for calibration procedures or service. Regular calibration by a qualified technician is recommended for applications requiring high precision.

7. Troubleshooting

ProblemPossible CauseSolution
Scale does not turn onNo power supply; dead batteries; faulty AC adapterCheck battery installation/charge; ensure AC adapter is properly connected and functional.
Inaccurate readingsScale not level; unstable surface; drafts; overload; calibration requiredPlace on a stable, level surface; avoid drafts; ensure weight is within capacity; consider professional calibration.
Display shows 'Err' or 'OL'OverloadRemove excess weight from the pan. Do not exceed maximum capacity.
Display is blank or flickeringLow battery; power connection issueReplace batteries or check AC adapter connection.

8. Specifications

FeatureSpecification
Model NumberHL-3000WPN
Capacity3000g / 6.6 lb / 105.8 oz
Readout Accuracy1g / 0.002 lb / 0.1 oz
MaterialStainless Steel
Item Weight5 Pounds
Form FactorMini Bench Scale
First AvailableSeptember 22, 2014

9. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the documentation included with your product or visit the official A&D Medical website. Contact details for customer service are typically provided on the manufacturer's website or in the product packaging.

Note: This manual provides general guidance. Specific warranty terms and support procedures may vary.

© 2023 A&D Medical. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.