Jessup Manufacturing Company 75-7072-B

User Manual: Jessup Glo Brite P75 Eco Exit Sign

Model: 75-7072-B

1. Product Overview

The Jessup Glo Brite 75-7072-B P75 Molded Plastic Double-Sided Eco Exit Sign is a non-electrical, photoluminescent safety signage solution designed for outdoor and wet locations. This sign provides reliable emergency egress guidance without requiring electricity, bulbs, or special wiring.

It is engineered for high- or low-level applications and can be mounted on various surfaces including walls, flags, ceilings, or conduits. Its thin profile ensures consistent, uniform illumination visible up to 75 feet, even during power outages or emergency blackout conditions.

Unlike traditional tritium exit signs, the Glo Brite photoluminescent signs are non-radioactive, non-toxic, and fully recyclable, contributing to environmental safety and eliminating health risks associated with radioactive materials. The sign is maintenance-free for over 25 years and meets stringent safety standards including UL924, NFPA Life Safety Code 101, OSHA requirements, and is compliant with 2009/2012/2015 IBC/IFC codes. It can also contribute to LEED credits.

Key Features:

  • Photoluminescent Technology: Absorbs and stores ambient light to glow brightly in darkness.
  • High Visibility: Provides consistent, uniform illumination visible at 75 feet (22.9 meters) in emergency blackout conditions.
  • Non-Electrical & Maintenance-Free: Requires no wiring, bulbs, or replacement parts, offering 25+ years of service life.
  • Environmentally Safe: Non-toxic, non-radioactive, and fully recyclable, unlike tritium signs.
  • Durable Construction: Molded plastic design suitable for outdoor and wet locations.
  • Code Compliant: Listed to UL924, meets NFPA Life Safety Code 101, OSHA, and IBC/IFC requirements.
  • LEED Credit Eligible: Can be used to obtain LEED credits.

2. Package Contents

  • One (1) Jessup Glo Brite 75-7072-B P75 Eco Exit Sign

3. Safety Information

This photoluminescent exit sign is designed for safety and requires no electrical connection, eliminating risks associated with electrical wiring. It is non-radioactive and non-toxic.

Important: For optimal performance, a minimum of 5 foot-candles (54 lux) of external unfiltered fluorescent illumination must be present on the sign face at all times of building occupancy. This ensures the sign absorbs sufficient light to glow effectively in dark conditions.

Ensure the mounting location is clear of obstructions that could block the sign's visibility or its ability to absorb ambient light.

4. Setup and Installation

The Jessup Glo Brite Eco Exit Sign is designed for straightforward installation without the need for electrical wiring or specialized housing.

4.1 Choosing a Location:

  • Select a location that is approved for exit signage and is visible from the intended viewing distance (up to 75 feet).
  • Ensure the sign will receive adequate ambient light (minimum 5 foot-candles / 54 lux of unfiltered fluorescent illumination) during building occupancy to charge its photoluminescent material.
  • The sign is suitable for outdoor and wet locations.

4.2 Mounting Options:

The sign can be mounted in various configurations:

  • Surface Mount: Directly to a wall or flat surface.
  • Flag Mount: Perpendicular to a wall.
  • Ceiling Mount: Suspended from a ceiling.
  • Conduit Mount: Attached to electrical conduit (though the sign itself is non-electrical).

Use appropriate fasteners (not included) for the chosen mounting surface to ensure secure installation.

Jessup Glo Brite Eco Exit Sign in normal light, showing red background with green 'EXIT' text and arrows.

Figure 1: Jessup Glo Brite Eco Exit Sign (Model 75-7072-B) under normal lighting conditions. The sign features a red background with the word "EXIT" and directional arrows in a light green, photoluminescent material. It is double-sided and listed to UL 924.

5. Operating Instructions

The Jessup Glo Brite Eco Exit Sign operates passively by absorbing ambient light and then emitting it in dark conditions.

  • During periods of normal lighting, the photoluminescent material on the sign absorbs energy from light sources.
  • When ambient light levels drop (e.g., during a power outage or emergency blackout), the stored energy is released as visible light, causing the "EXIT" text and arrows to glow brightly.
  • The sign is designed to provide consistent, uniform illumination visible at a distance of 75 feet (22.9 meters) in dark conditions, guiding occupants to exits.
Jessup Glo Brite Eco Exit Sign glowing in the dark, showing bright green 'EXIT' text and arrows against a dark background.

Figure 2: Jessup Glo Brite Eco Exit Sign (Model 75-7072-B) demonstrating its photoluminescent glow in a dark environment. The "EXIT" text and directional arrows are clearly visible in a bright green hue, indicating its functionality during emergency blackouts.

6. Maintenance

One of the primary advantages of the Jessup Glo Brite Eco Exit Sign is its minimal maintenance requirement.

  • Service Life: The sign is designed to be maintenance-free for over 25 years. It does not require bulb replacements, battery checks, or electrical system inspections.
  • Cleaning: Periodically inspect the sign for dust or dirt accumulation. Clean the sign face with a soft, damp cloth and mild soap if necessary. Avoid abrasive cleaners or solvents, as these may damage the photoluminescent surface.
  • Inspection: Regularly check that the sign is securely mounted and that its visibility is not obstructed. Ensure the area around the sign receives adequate ambient light during building occupancy to allow for proper charging.

7. Troubleshooting

As a non-electrical device, troubleshooting for the Glo Brite Eco Exit Sign is generally limited to environmental factors.

  • Sign is not glowing sufficiently in the dark:
    • Check Ambient Light: Verify that the sign is exposed to a minimum of 5 foot-candles (54 lux) of unfiltered fluorescent illumination during building occupancy. Insufficient light exposure will prevent proper charging.
    • Obstructions: Ensure no objects are blocking the sign's surface from receiving light or obstructing its visibility.
    • Cleanliness: Clean the sign face to remove any dust or grime that might be impeding light absorption or emission.
  • Sign appears damaged:
    • If the sign's integrity is compromised (e.g., cracks, severe discoloration), it may need to be replaced to ensure compliance and effectiveness.

8. Specifications

Model Number75-7072-B
BrandJessup Manufacturing Company
Product Dimensions8.5"L x 16"W (21.6 cm x 40.6 cm)
MaterialMolded Plastic
ColorRed (background), Green (EXIT text/arrows)
Item Weight3.8 Pounds (1.72 kg)
Mounting TypeWall Mount, Flag Mount, Ceiling Mount, Conduit Mount
Viewing Distance75 feet (22.9 meters)
Certifications/ComplianceUL924 Listed, NFPA Life Safety Code 101, OSHA, 2009/2012/2015 IBC/IFC Compliant, LEED Credit Eligible
Service Life25+ years (maintenance-free)
UPC717364172754

9. Warranty and Support

For specific warranty information or technical support regarding your Jessup Glo Brite Eco Exit Sign, please contact Jessup Manufacturing Company directly. Refer to the product packaging or the manufacturer's official website for the most current contact details and warranty terms.

Given the product's maintenance-free design and 25+ year service life, direct support needs are typically minimal.

© 2023 Jessup Manufacturing Company. All rights reserved.

Jessup Glo Brite 75-7072-B P75 Eco Exit Sign User Manual.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.