Introduction
This manual provides comprehensive instructions for the safe installation, operation, and maintenance of your American Lighting LED Complete 2 Under Cabinet Fixture. This 120-Volt dimmable warm white LED fixture is designed for efficient and uniform lighting in various indoor applications.

Image: The American Lighting LED Complete 2 Under Cabinet Fixture, a white, rectangular LED light bar with a switch on the front, designed for under-cabinet installation.
Important Safety Information
WARNING:
- Read all instructions before beginning installation.
- This product may represent a possible shock or fire hazard if improperly installed or attached in any way. Products should be installed in accordance with these instructions, current electrical codes, and/or the current National Electric Code (NEC).
- To reduce the risk of fire, electric shock, or injury to persons, pay close attention to this manual and stay within its guidelines when using this product.
- Ensure that the voltage of your power supply is compatible (120V AC).
- Do not exceed 5 AMPS maximum load.
- For use with 120V 60Hz power supply only.
- Wiring must be completed before mounting.
- All fixtures connected to junction box must be mounted.
- Do not install in wet environments. For indoor, dry location use only.
- Qualified electricians in accordance with local electrical codes should perform all installations.
- UL approved dimmers may be used with the LED Complete (ALC Series) dimmable under cabinet fixtures.
- This product is suitable for use in dimming circuits.
- Always disconnect electrical power to the product before cleaning or putting on or taking off parts.
- Do not operate this product if jumper cable has been damaged.
- Keep jumper cable away from sources of heat and heated surfaces.
- Do not operate this product in environments where aerosol sprays are being used or where oxygen is being administered.
- For cleaning, use a soft, dry damp cloth. Do not use harsh chemicals or abrasives.
CAUTION:
- To reduce the risk of electric shock, do not use this junction box or jumper cables for the ALC series (part numbers ALC-length-color) to provide power to any products other than the LED Complete fixtures (ALC Series).
- To reduce the risk of fire, electric shock, or injury to persons, do not operate fixture with missing or damaged lens or wiring compartment cover.
- To reduce the risk of electric shock or injury to persons, do not operate without end connector cover(s) in place for any molex ports/connectors not in use.
- Not intended for recessed installation in ceilings or soffits.
- LEDs are bright! Do not look directly at LED light source.
- Do not touch LEDs.
- There are no serviceable parts inside the LED module.

Image: A page from the installation instructions detailing important safety information, warnings, and pre-installation notes for the LED Complete 2 series.
Setup and Installation
The American Lighting LED Complete 2 fixture offers flexible installation options, including direct wire and linking multiple units.
Mounting the Fixture
- Determine locations for each fixture. For hardwire installations, connect supply wires via knockouts before mounting.
- Use a Phillips head screwdriver or driver bit to tighten captive mounting screws and secure fixture to an appropriate mounting surface.

Image: Diagram showing the mounting points and rear access door of the fixture. It illustrates how to secure the fixture to a surface using screws.
Connecting Power via Rear Access Door
This method is used for hardwiring the fixture directly to a power source.
- The rear access door is located in the center of the back of the fixture housing. It has its own knockout for quick connection to supply wires, foregoing the need to remove the lens cover and open the wiring compartment.
- Remove knockout using a hammer or punch, then loosen the screw that secures the rear access door using a Phillips head screwdriver or driver bit.
- Install the 3/8" cable connector (included) for the supply wire following National Electric Code and local codes through this knockout on the access door. Ensure to use 14AWG or 12AWG wire. AC should be protected by circuit breaker or fuse.
- Strip back jacket on supply wires to 3/8" and use push-in connectors inside housing to connect the wires, matching polarity (Black=Black, Hot; White=White, Neutral; Yellow/Green=Bare Wire = Ground) through knockout so that push-in connectors are positioned on the housing side of the access door.
- Replace rear access door and tighten retaining screw. Be sure that the wires are not pinched or damaged by any part of the housing or the cover.

Image: Detailed diagram illustrating the rear access door, knockout, and push-in wire connectors for hardwiring the fixture. It shows how to connect the electrical wires securely.
Interconnecting Fixtures
Multiple fixtures can be linked together for continuous lighting.
Interconnecting via Linking/Jumper Cable
- To interconnect nearby fixtures, remove the adjacent port covers and utilize the ALC-EX linking cable (sold separately).
- If needed, linking cables can be interconnected to make longer lengths.

Image: Diagram showing how to link multiple LED Complete 2 fixtures using an inline connector or jumper cable. It illustrates the connection points on the side of the fixtures.
Interconnecting via End-to-End Linking
To interconnect fixtures directly to each other (end-to-end), utilize the in-line connector (included with each fixture) by removing adjacent port covers and inserting fully.
Direct Wire Junction Box Installation (for ALC-BOX-##)
This type of installation is less common and typically only done when the rear access door cannot be utilized.
- Open wiring compartment by removing screws and open the end of the fixture cover from housing body.
- Punch out whichever knockout is best suited for connection to 120V supply wire.
- Install cable connector and connect fixture wires following National Electric Code and/or local building code requirements. Minimum 18AWG solid copper wire. AC lead should be 120V protected by circuit breaker or fuse.
- Attach line voltage supply wires to fixture lead wires with wire nuts/WAGO. White to White/Neutral and Yellow/Green (Ground) to Green or bare wire inside the fixture. Secure each connection using push-in wire connectors provided on the fixture lead wire. If your system has no ground wire, consult a qualified electrician before proceeding with the installation.
- Do not install in wet environment.
- Replace the wiring compartment cover, securing with the existing retaining screws. Note: Be sure that the wires are not pinched or damaged by any part of the housing or the cover.
- Follow directions above for mounting fixture.

Image: Diagram detailing the direct wire junction box installation for the LED Complete 2 fixture. It shows the components like the junction box, electrical port, and push-in connectors, along with wiring instructions.
Operating Instructions
Powering On/Off
The fixture is equipped with a switch for basic on/off control. For hardwired installations, the fixture will operate via the wall switch connected to the circuit.
Dimming
The American Lighting LED Complete 2 fixture is dimmable. Use a compatible 120V dimmer switch (UL approved) for optimal performance. Refer to the "Compatible Dimmers" section for recommended models.

Image: A page from the product information showing recommended power supplies, accessories, and a table of compatible dimmers from various brands, including model numbers and dimming ranges.
Maintenance
Cleaning
To clean the fixture, ensure power is disconnected. Use a soft, dry, or slightly damp cloth. Do not use harsh chemicals, abrasive cleaners, or solvents, as these can damage the finish or electrical components.
LED Module
The LED module within this fixture is not user-serviceable. Do not attempt to open or repair the LED module.
Troubleshooting
If your American Lighting LED Complete 2 fixture is not functioning as expected, please review the following common issues and solutions:
- Fixture does not light up:
- Check if the power supply is connected and the circuit breaker is on.
- Ensure all wiring connections are secure and correct, especially for hardwired installations.
- Verify that the fixture's on/off switch (if present) is in the "on" position.
- Confirm that the voltage supplied is 120V AC.
- Light output is inconsistent or flickering:
- Ensure a compatible dimmer switch is being used. Incompatible dimmers can cause flickering or poor dimming performance.
- Check for loose wiring connections.
- Fixture is damaged:
- If the lens or wiring compartment cover is missing or damaged, discontinue use and contact customer support.
- Do not operate if the jumper cable is damaged.
If these steps do not resolve the issue, please contact American Lighting customer support.
Specifications
| Feature | Detail |
|---|---|
| Model Number | ALC2-12-WH |
| Input Voltage | 120V AC, 60Hz |
| Wattage | 4 watts |
| Brightness | 273 Lumens |
| Color Temperature (CCT) | 3000K (Warm White) |
| Color Rendering Index (CRI) | 90+ |
| Dimmable | Yes (with compatible 120V dimmers) |
| Rated Life | 35,000 hours |
| Dimensions (L x W x H) | 12.25 x 4 x 0.94 inches |
| Material | Powder Coated Aluminum Housing, Acrylic Lens |
| Mounting Type | Surface Mounted, Under Cabinet |
| Indoor/Outdoor Usage | Indoor Use Only |
| Certifications | cETLus Listed (dry location), ENERGY STAR certified |

Image: A page from the product brochure detailing technical specifications for the LED Complete 2 series, including input voltage, CCT, CRI, wattage, lumens, and rated life.
Warranty
This American Lighting product is warranted to be free from defects in material and workmanship for a period of five years from the date of purchase. Products that prove to be defective during this period will be either repaired (i.e. replacement of defective electronic parts) or, at the discretion of American Lighting, Inc., exchanged for a new or reconditioned product.
This warranty does not cover damage due to improper installation, accident, abuse, misuse, or normal wear and tear. It also does not cover incidental or consequential damages.
For complete warranty terms and conditions, please refer to the official American Lighting website or contact customer support.
Customer Support
For technical assistance, warranty claims, or additional information, please contact American Lighting:
- Website: www.americanlighting.com
- Address: 11775 E. 45th Ave. Denver, CO 80239
- Phone: 1-800-880-1180
- Fax: 303-695-7633