American Lighting ALC2-12-DB

American Lighting ALC2 LED Complete 2 Undercabinet Fixture Instruction Manual

Model: ALC2-12-DB

Brand: American Lighting

Product Overview

The American Lighting ALC2-12-DB is a 12.25-inch LED undercabinet fixture in Dark Bronze, part of the LED Complete 2 Collection. This dimmable, energy-efficient fixture is designed for various installation needs, offering warm white light (3000K) with a high Color Rendering Index (CRI) of 90+. It boasts a long lifespan of up to 35,000 hours and provides high light output, being significantly brighter than traditional xenon undercabinet lights.

Its modular design allows for flexible installation with optional hardwire junction boxes, power cords, and linking cables (sold separately). The fixture features a full-length acrylic lens for even light diffusion, side power input for easy connections, and captive screws for quick mounting. Its low-profile design, under 1-inch high, ensures discreet integration under cabinets.

American Lighting ALC2 LED Undercabinet Fixture in Dark Bronze

Image: The ALC2-12-DB LED undercabinet fixture, showcasing its slim profile and dark bronze finish.

Key Features:

Important Safety Information

WARNING: These products may represent a possible shock or fire hazard if improperly installed or attached in any way. Products should be installed in accordance with these instructions, current electrical codes, and/or the current National Electric Code (NEC).

Read all instructions before beginning. Save these instructions for future use.

Setup and Installation

The ALC2 LED Complete 2 Undercabinet fixture offers flexible installation options, including direct wiring or connection via accessories (sold separately).

Mounting the Fixture:

  1. Determine locations for each fixture. For hardwire installations, connect supply wires via knockouts before mounting.
  2. Use a Phillips head screwdriver or driver bit to tighten captive mounting screws and secure fixture to an appropriate mounting surface.
Installation Instructions Diagram Page 1

Image: Page 1 of the installation instructions, showing mounting and wiring access.

Connecting Power:

The ALC2 fixture can be powered by an adjacent fixture using linking cables, or hardwired directly via the Hardwire Junction Box (ALC-BOX, sold separately), or powered by a 120V power cord (ALC-PC6, sold separately).

Connecting Power via Rear Access Door (Figures 1 & 2):

The rear access door is located in the center of the back of the fixture housing. It has its own knockout for quick connection to supply wires, bypassing the need to remove the lens cover and open the wiring compartment.

  1. Remove knockout using a hammer or punch, then loosen the screw that secures the rear access door using a Phillips head screwdriver or driver bit.
  2. Install the 3/8" cable connector (included) for the supply wire following National Electric Code and local codes through this knockout on the access door. Use 14AWG or 12AWG wire. AC should be protected by circuit breaker or fuse.
  3. Strip back jacket on supply wires to 3/8" and use push-in connectors inside housing to connect the wires, matching polarity (Black=Black, Hot; White=White, Neutral; Yellow/Green=Ground). Ensure that push-in connectors are positioned on the housing side of the access door.
  4. Replace rear access door and tighten retaining screw. Be sure that the wires are not pinched or damaged by any part of the housing or the cover.
Rear Access Door Wiring Diagram

Image: Diagram illustrating the rear access door for wiring connections.

Connecting Power via Supply Wires Through Housing Knockouts (Figures 6 & 7):

This type of installation is less common and typically only done when the rear access door cannot be utilized.

  1. Open wiring compartment by removing screws on each end of the fixture cover from housing body.
  2. Punch out whichever knockout is best suited for connection to 120V supply wire. Knockouts are located along back and top of housing.
  3. Install cable connector and connect fixture wires following National Electric Code and/or local building code requirements. Minimum 18AWG solid copper wire. AC should be 120V protected by circuit breaker or fuse.
  4. Attach line voltage supply wires to fixture lead wires with wire nuts: Black to Black/Hot, White to White/Neutral and Yellow/Green (Ground) to Green or bare wire inside the fixture. Secure each connection using push-in wire connectors provided on the fixture lead wire.
  5. Replace wiring compartment cover, ensuring no wires are pinched.
Housing Knockout Wiring Diagram

Image: Diagram showing wiring through housing knockouts.

Direct Wire Junction Box Installation (ALC-BOX, sold separately) (Figure 1, above):

This method is used to hardwire the fixture to a power source. The ALC-BOX is designed for use with LED Complete (ALC Series) Undercabinet Lights.

  1. Turn off power for appropriate electrical circuit at electrical service panel.
  2. Remove junction box cover screws and remove cover. Save screws and lock-washers.
  3. Prepare flat, non-metallic cable (NM/2C+Ground) or armored cable (BX) by stripping conductor ends approximately 3/8".
  4. For installation using 3/8" electrical connector (junction box as shown), determine mounting orientation and remove one side knockout on desired side of junction box. Attach 3/8" electrical connector to junction box then affix 3/8" electrical connector to electrical supply (BX or NM). NM cable outer jacket must protrude through 3/8" electrical connector to adequately protect internal conductors.
  5. Tighten locknut and clamping screw(s) on electrical connector, fitting securely.
  6. Use stripped ends of wires into the push-in wire connectors (see Figure 1). Supply wires are typically color coded: Hot-black, Neutral-white, Ground-green or bare copper.
  7. Push excess electrical supply wire back into wall and locate the junction box on mounting surface. Affix the junction box to the underside of the cabinet with captive screws provided.
  8. Replace and secure junction box cover with supplied screws. Make sure lock-washers are located beneath screw heads for proper ground.
  9. Follow installation instructions provided with undercabinet light fixture. Mount fixture, and insert jumper wire (sold separately) or direct end-to-end connector (supplied with fixture) into appropriate electrical port of direct wire junction box.
  10. Make sure that all fixtures connected to junction box are properly installed and that all open electrical ports on the module and fixtures are safely covered with electrical port covers.
  11. Restore circuit power at electrical service panel. Turn on master switch on junction box and turn on switches for each individual fixture. Master switch can be used to control all fixtures simultaneously or fixtures can be operated individually.
Direct Wire Junction Box Diagram

Image: Diagram illustrating the components and wiring for the direct wire junction box.

Interconnecting Fixtures:

Adjacent fixtures can be linked using linking/jumper cables (ALC-EX6-BK/WH, ALC-EX12-BK/WH, sold separately) or end-to-end connectors (ALC-CON-BK/WH, sold separately).

Installation Instructions Diagram Page 2

Image: Page 2 of the installation instructions, detailing linking and jumper cable connections.

Operating Instructions

The American Lighting ALC2 LED Complete 2 Undercabinet fixture is designed for simple operation once installed.

Powering On/Off:

If connected to a wall switch or the master switch on a junction box (ALC-BOX), simply use the switch to turn the fixture on or off.

Dimming Functionality:

This fixture is dimmable and compatible with most CL (CFL/LED) and ELV (Electronic Low Voltage) dimmers. For optimal performance, refer to the "Compatible Dimmers" section in the specifications or consult a qualified electrician for dimmer compatibility.

Adjust the dimmer switch to achieve the desired light level. The fixture provides warm white light at 3000K.

Maintenance

The ALC2 LED Complete 2 Undercabinet fixture requires minimal maintenance due to its long-lasting LED technology.

Cleaning:

LED Module:

There are no serviceable parts inside the LED module. Do not attempt to open or repair the LED module yourself.

Troubleshooting

If you encounter issues with your ALC2 LED Complete 2 Undercabinet fixture, please refer to the following common troubleshooting steps:

For issues not resolved by these steps, please contact American Lighting customer support.

Specifications

Ordering Information and Accessories

Image: Diagram showing ordering information, available sizes, finishes, and compatible accessories.

General Product Specifications
AttributeValue
BrandAmerican Lighting
Model NameLED Complete 2 Collection
Part NumberALC2-12-DB
ColorDark Bronze
Size12 inches (12.25 x 4 x 0.94 inches)
MaterialGlass, Acrylic (Shade)
Style1-Pack
Room TypeKitchen
Indoor/Outdoor UsageIndoor
Power SourceCorded Electric (accessories sold separately)
Installation TypeSurface Mount, Under Cabinet
Special FeatureDimmable
Control MethodTouch (via compatible dimmer)
Light Source TypeLED
Finish TypeBronze
Number of Light Sources2
Voltage120 Volts
Light ColorWarm White (3000K)
Wattage4 watts
Brightness238 Lumens
Efficiency59.5 lumens per watt
Rated Life35,000 hours
UPC714176005461

Compatible Dimmers:

BrandModel #TypeDimming Range
Lutron DivaDVCL-153PUniversal (CFL/LED/Incandescent)5-100%
Lutron DivaDVELV-300PElectronic Low Voltage (ELV)5-100%
Lutron Sureslide6613Magnetic Low Voltage (MLV)5-100%

Note: Dimmer performance may vary in field application due to unknown external factors. Dimmers not included on the chart above are not necessarily incompatible; they have yet to be fully evaluated. Please reference dimmer manufacturer's instructions for more detailed information regarding performance and compatibility.

Warranty Information

5-Year Limited Product Warranty:

This product is warranted to be free from defects in material and workmanship for a period of five years from the date of purchase. This warranty applies to the fixture during this period and will be either repaired (i.e. replacement of defective electronic components) or replaced (i.e. replacement of the entire fixture, lamp sockets, excluding the lamp) or replaced, at the discretion of American Lighting, Inc. Claims for defective products must be submitted to the retail store from which the product was purchased to obtain warranty. Upon submission of proper return claim documentation and product to American Lighting, Inc. by the retailer, American Lighting, Inc. will reserve the right to inspect the product for misuse or abuse. Claims for defects or inconveniences of products that are not an American Lighting, Inc. original product will be denied. This is a warranty of product reliability only and not a warranty of merchantability or fitness for a particular purpose. American Lighting, Inc. shall have no liability whatsoever for incidental or consequential damages, including without limitations, installation costs and damages for personal injury and property. These products may represent a possible shock or fire hazard if improperly installed or attached in any way. This warranty applies only to products that have been installed in accordance with instruction sheet and current local codes and/or the National Electrical Code. Warranty does not apply to any product that has been improperly installed or in situations where components have been altered in any way.

For questions, comments, technical assistance or an inquiry, please call toll free at: 1-800-285-8051 (M-F 8am - 5pm, MST).

Customer Support

For further assistance, technical support, or warranty claims, please contact American Lighting:

Please have your product model number (ALC2-12-DB) and purchase information ready when contacting support.

Related Documents - ALC2-12-DB

Preview American Lighting 120V 12 Pack LED Disc Lights Installation Instructions
Detailed installation instructions for American Lighting's 120V 12 Pack LED Disc Lights (models RD6-30-WH-12PK, RD6-5CCT-WH-12PK, QD6-30-WH-12PK, QD6-5CCT-WH-12PK). Includes safety information, fixture contents, installation steps, and maintenance.
Preview American Lighting RHYM Series 120V Recessed Downlight Installation Guide
Comprehensive installation instructions for the American Lighting RHYM Series 120V recessed downlight, covering safety, new construction and remodel installation, wiring, optic lens replacement, care, maintenance, FCC compliance, and warranty.
Preview American Lighting Spektrum+ 6" Disc Light Installation Guide (SPKPL-DISC6-RGBTW-WH)
Detailed installation instructions and safety information for the American Lighting Spektrum+ 6" RGB+TW Disc Light (Model SPKPL-DISC6-RGBTW-WH). Learn how to safely install and control this smart LED fixture.
Preview 12-24V DMX 5 Channel RJ45 Decoder Installation Instructions
Comprehensive installation and operating instructions for the REC-DMX-RJ45A-5CH, a 12-24V DMX 5 Channel RJ45 Decoder. Learn about wiring, setup modes, DMX addressing, and safety precautions for optimal performance in lighting control systems.
Preview American Lighting Hybrid 3 Kits: 120V AC Flexible Linear LED Lighting
Explore American Lighting's Hybrid 3 Kits, offering 120V AC flexible linear LED lighting with superb output, IP65 rating, and 50,000-hour lifespan. Ideal for indoor and outdoor applications. View specifications, ordering information, and warranty details.
Preview 24V Trulux Static White (IP54) HTMR-COB Series Installation Instructions
Installation guide for American Lighting's 24V Trulux Static White HTMR-COB Series LED tape light, detailing safety precautions, maximum run lengths, mounting procedures, and a 5-year limited warranty.