Güde 415/10/50 N

Güde KOMPRESSOR 415/10/50 N Instruction Manual

Model: 415/10/50 N

1. Introduction

This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your Güde KOMPRESSOR 415/10/50 N. Please read this manual thoroughly before operating the compressor and keep it for future reference.

Güde KOMPRESSOR 415/10/50 N, a blue air compressor with a 50-liter tank, two wheels, and a black handle.

Figure 1: Overview of the Güde KOMPRESSOR 415/10/50 N.

2. Safety Instructions

Always observe the following safety precautions to prevent injury and damage to the equipment:

  • Ensure the compressor is placed on a stable, level surface.
  • Do not operate the compressor in wet or damp conditions.
  • Wear appropriate personal protective equipment (PPE), including eye and hearing protection.
  • Before any maintenance or inspection, disconnect the compressor from the power supply and ensure the tank is depressurized.
  • Regularly check all connections and hoses for leaks or damage.
  • Do not direct compressed air at people or animals.

3. Setup

Follow these steps for initial setup:

  1. Unpacking: Carefully remove the compressor and all components from the packaging. Inspect for any shipping damage.
  2. Wheel Assembly: Attach the wheels to the designated axles on the compressor base. Secure them firmly.
  3. Feet Installation: Ensure the rubber feet are securely attached to the tank's support brackets to provide stability and reduce vibration.
  4. Oil Level Check: Verify the oil level in the V-aggregate. The compressor is equipped with oil lubrication. Refer to the sight glass for the correct level.
  5. Power Connection: Connect the power cable to a grounded 230 V/50 Hz electrical outlet. Ensure the circuit can handle the 2.2 kW motor power.
Close-up of the blue compressor's base showing the sturdy metal feet with black rubber caps.

Figure 2: Detail of the double tank base and rubber feet for stability.

Close-up of the compressor's wheels and the water drain valve located at the bottom of the tank.

Figure 3: Wheels and condensate water drain valve.

4. Operating Instructions

To operate your Güde compressor:

  1. Power On: Switch on the compressor using the main power switch. The motor will start, and the tank will begin to fill with compressed air.
  2. Pressure Monitoring: Monitor the pressure gauges. One gauge shows the tank pressure, and the other shows the regulated output pressure.
  3. Pressure Adjustment: Use the pressure reducer knob to set the desired output pressure for your tools. Turn clockwise to increase pressure, counter-clockwise to decrease.
  4. Connecting Tools: Attach your compressed air tools to the universal couplings.
  5. Automatic Operation: The compressor will automatically shut off when the maximum pressure (10 bar) is reached and restart when the pressure drops below a set threshold.
Close-up of the compressor's control panel, showing the red pressure regulator knob, two pressure gauges (manometers), and a universal coupling.

Figure 4: Pressure regulator and manometers.

Close-up of the compressor's motor and pump assembly, highlighting the V-aggregate and cooling fins.

Figure 5: Motor and 2-cylinder V-aggregate.

5. Maintenance

Regular maintenance ensures the longevity and optimal performance of your compressor:

  • Condensate Drainage: Drain the condensate water from the tank daily or after each use. This prevents corrosion inside the tank. Use the water drain valve at the bottom of the tank.
  • Oil Change: Change the compressor oil according to the manufacturer's recommendations (typically after the first 50 hours, then every 200-300 hours). Use only specified compressor oil.
  • Air Filter Cleaning/Replacement: Inspect and clean the air filter regularly. Replace if heavily soiled or damaged to ensure proper air intake and prevent motor strain.
  • General Cleaning: Keep the compressor clean and free of dust and debris, especially around the motor and cooling fins.

6. Troubleshooting

Common issues and their solutions:

ProblemPossible CauseSolution
Compressor does not startNo power supply; Motor protection switch trippedCheck power connection; Reset motor protection switch
Low air pressure/slow fillingAir leaks; Clogged air filter; Worn piston ringsCheck connections for leaks; Clean/replace air filter; Contact service for repair
Excessive noise/vibrationLoose components; Insufficient oil; Worn bearingsTighten all fasteners; Check/add oil; Contact service
Oil leakageLoose drain plug; Damaged sealsTighten plug; Contact service for seal replacement

7. Specifications

FeatureSpecification
Model Number415/10/50 N
Motor Power (P1)2.2 kW
Connection230 V / 50 Hz
Suction Capacity435 l/min
Delivery Capacity302 l/min
Max. Pressure10 bar
Tank Volume50 l
Noise Level96 dB
Weight66 kg
Dimensions (L x W x H)97 x 40 x 40 cm
MaterialKunststoff (Plastic)
Included Components50-liter pressure vessel, 2 V-cylinder compressor with oil lubrication, 2 manometers, pressure regulator, 2 universal couplings, condensate water drain valve, power cable

8. Warranty and Support

Güde is committed to providing excellent support and service. Should you encounter any issues or require assistance with your KOMPRESSOR 415/10/50 N, our dedicated team is available to provide advice and support even after your purchase. Please refer to your purchase documentation for specific warranty terms and contact information.

For further assistance, please visit the official Güde website or contact their customer service department.

© 2024 Güde. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.