Warming Systems 20cable120-OJ
Warming Systems 120V Electric Radiant Floor Heating Cable with Touch Screen Programmable Thermostat (20 Sq Ft)
Model: 20cable120-OJ
Brand: Warming Systems
Introduction
This manual provides comprehensive instructions for the installation, operation, and maintenance of your Warming Systems 120V Electric Radiant Floor Heating Cable and UDG4-4999 Touch Screen Programmable Thermostat. This system is designed to provide comfortable, even heat to your tiled floors, enhancing the comfort of your living space. Please read this manual thoroughly before beginning installation or operation to ensure safe and efficient use.

Figure 1: Complete Warming Systems Electric Radiant Floor Heating Kit.
The Warming Systems electric radiant floor heating system offers a luxurious feeling by warming the floor and objects in the room. This radiant heat prevents your body from losing heat to cold surfaces, creating a comfortable and cozy environment. It is particularly beneficial for tile floors, which can often feel cold to the touch.
Video 1: An animated overview of how Warming Systems electric floor heat works to provide comfort in your home.
Safety Information
- All electrical work must be performed by a qualified electrician in accordance with local and national electrical codes.
- The system is UL LISTED for USA and Canada, and safe for wet areas, including showers.
- Always use the included Installation Warning Monitor during installation. This device will sound an alarm if the heating wire is damaged, helping to prevent issues before the floor is laid.
- Ensure the thermostat is GFCI protected. The UDG4-4999 thermostat includes built-in GFCI protection.
- Do not install heating cables under fixed objects such as cabinets, bathtubs, or toilets unless specifically designed for such applications and approved by local codes.
Components Included
- 20 Square Foot Electric Floor Warming Cable (80 feet long)
- Touch Screen GFCI Protected Digital Programmable Thermostat (Model: UDG4-4999)
- Floor Temperature Sensor
- Installation Warning Monitor (alarm sounds if wire is damaged during installation)
- Plastic Cable Guides (for cable system installation)

Figure 2: Labeled components of the Warming Systems Electric Radiant Floor Heating Kit.
Setup and Installation
Proper installation is crucial for the safe and efficient operation of your radiant floor heating system. Always consult a qualified electrician for electrical connections and ensure compliance with all local building codes.
1. Planning the Layout
Before laying the cable, plan the heated area carefully. The heating cable should be run approximately 3 inches apart. Avoid installing heating cables under permanent fixtures like cabinets, bathtubs, or toilets. Maintain a minimum distance of 2 inches from walls and fixtures, and at least 6 inches from the center of a toilet wax ring.

Figure 3: Example layout for cable installation in a bathroom, showing recommended spacing and areas to avoid.
2. Cable System Installation
The electric floor heating cable comes on a spool. This system is ideal for areas with irregular shapes or where you need to heat around objects. The cable is laid out by hand, maintaining a 3-inch spacing. Plastic cable guides are used to secure the cable to the subfloor.

Figure 4: Plastic cable guides for securing the heating cable at 3-inch intervals.
The cold lead of the cable should be run up the wall to the electrical box where the thermostat will be installed. Ensure the cable is not damaged during installation. The Installation Warning Monitor should be connected to the cable during this process to alert you of any breaks.
Video 2: A demonstration of the cable installation process for Warming Systems electric floor heating.
3. Thermostat Installation
The UDG4-4999 Touch Screen Programmable Thermostat is designed for wall mounting. It includes a floor sensor that must be embedded in the floor near the heating cable to accurately measure floor temperature. Follow the wiring diagrams provided with the thermostat for correct electrical connections. The thermostat operates on 120 Volts and is rated for 16 Amps.

Figure 5: UDG4-4999 Touch Screen Programmable Thermostat interface.
Operating Instructions
The UDG4-4999 Touch Screen Programmable Thermostat allows for easy and accurate control of your floor heating system. Its programmable features help optimize comfort and energy savings.
- Power On/Off: Use the On/Off/GFCI Reset button (typically on the side) to power the unit.
- Setting Temperature: Use the up/down arrows on the touch screen to adjust the target temperature.
- Programming Schedule: Access the menu to set a heating schedule. This allows the system to automatically adjust temperatures based on your daily routine, maximizing energy efficiency.
- GFCI Test: Regularly test the Ground Fault Circuit Interrupter (GFCI) by pressing the GFCI Test Button to ensure proper safety function.
- Heating Indicator: The display will show a heating indicator when the system is actively warming the floor.
For detailed programming instructions, refer to the specific user guide provided with your UDG4-4999 thermostat.
Maintenance
The Warming Systems electric radiant floor heating system is designed for long-term, maintenance-free operation once properly installed. However, regular checks can ensure continued performance:
- GFCI Testing: Test the GFCI on your thermostat monthly to ensure it is functioning correctly.
- Visual Inspection: Periodically inspect the thermostat for any visible damage or loose connections.
- Cleaning: Clean the thermostat screen with a soft, dry cloth. Avoid abrasive cleaners.
- Professional Check: If you suspect any issues with the heating system, contact a qualified electrician for inspection and repair. Do not attempt to repair the heating cable or thermostat yourself.
Troubleshooting
If your radiant floor heating system is not operating as expected, consider the following common issues before contacting support:
- No Heat:
- Check if the thermostat is powered on and set to a heating mode.
- Verify the target temperature is set higher than the current floor temperature.
- Check if the GFCI has tripped. Press the reset button on the thermostat.
- Ensure the circuit breaker for the heating system has not tripped.
- Uneven Heating:
- This is typically a result of improper cable spacing during installation. If this occurs, professional assessment may be required.
- Thermostat Display Issues:
- Ensure power supply is stable.
- If the screen is unresponsive, try resetting the thermostat (refer to thermostat manual).
For persistent issues, refer to the detailed troubleshooting section in your thermostat's specific manual or contact Warming Systems customer support.
Specifications
| Feature | Specification |
|---|---|
| Heated Area | 20 Square Feet |
| Cable Length | 80 linear ft |
| Voltage | 120V (AC) |
| Amperage | 2 Amps |
| Wattage | 240 Watts (12 Watts/sq ft) |
| Cable Thickness | 1/8 inch |
| Thermostat Model | UDG4-4999 |
| Thermostat Type | Digital Touch Screen Programmable, GFCI Protected |
| Safety Certification | UL Listed for USA and Canada |
| Installation Method | Floor-Mounted |
| Item Model Number | 20cable120-OJ |
Warranty and Support
Warming Systems stands behind the quality of its products. This electric radiant floor heating system comes with a 25-year warranty.
For any questions regarding installation, operation, or technical support, Warming Systems offers dedicated Engineering Support. You can contact them directly for assistance.
For further information or to contact support, please visit the Warming Systems Store on Amazon or refer to the contact information provided with your product packaging.

Figure 6: Warming Systems products are proudly Made in the USA.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.