1. Introduction

This manual provides essential instructions for the safe and effective use of your Smiledt Marathon III Micromotor Micro Motor Handle. Please read this manual thoroughly before operating the device and retain it for future reference. This complete set includes a control unit, handpiece, handpiece stand, chuck wrench, and foot pedal, designed for precision work with a maximum speed of 35,000 RPM.

2. Safety Information

  • Always ensure the power supply matches the device's voltage (110V).
  • Do not operate the device with wet hands or in damp conditions.
  • Disconnect the power cord before cleaning or performing any maintenance.
  • Wear appropriate eye protection during operation.
  • Keep the device out of reach of children.
  • Avoid touching rotating parts during operation.
  • Do not use damaged accessories or attachments.

3. Package Contents

Verify that all items are present in your package:

  • Control Unit
  • Marathon H37SN Handpiece (with 3/32" chuck size)
  • Handpiece Stand
  • Chuck Wrench
  • Foot Pedal (On/Off type)
Smiledt Marathon III Micromotor complete set including control unit, handpiece, and foot pedal

Image 3.1: Overview of the Smiledt Marathon III Micromotor complete set, showing the control unit, handpiece, and foot pedal.

4. Setup

  1. Connect Power: Ensure the control unit's power switch is in the 'OFF' position. Plug the power cord into a standard 110V AC outlet. The power input is located at the rear of the control unit.
  2. Rear view of the control unit showing the power input and fuse cap

    Image 4.1: Rear view of the control unit, highlighting the power input and fuse cap.

  3. Connect Handpiece: Insert the handpiece connector cable into the 'MOTOR' port on the front panel of the control unit. Ensure a secure connection.
  4. Connect Foot Pedal: Plug the foot pedal cable into the designated foot pedal port on the front panel of the control unit.
  5. Place Handpiece: Position the handpiece on the provided handpiece stand for convenient access and to prevent damage.
  6. Insert/Change Bur:
    • To insert a bur, ensure the handpiece is off. Rotate the handpiece chuck counter-clockwise until it opens.
    • Insert the desired 3/32" HP shank bur fully into the chuck.
    • Rotate the chuck clockwise to tighten it securely. Use the chuck wrench if necessary for a firm grip, but do not overtighten.
    • To remove a bur, reverse the process.
  7. Handpiece, coiled cord, chuck wrench, and carbon brushes

    Image 4.2: Components for handpiece operation and maintenance, including the handpiece, coiled cord, chuck wrench, and carbon brushes.

5. Operating Instructions

  1. Power On: Flip the main 'ON/OFF' switch on the control unit to the 'ON' position. The power indicator light (PL) should illuminate.
  2. Adjust Speed: Use the 'R.P.M' dial to set the desired rotational speed. Rotate clockwise to increase speed (MAX 35,000 RPM) and counter-clockwise to decrease speed (MIN).
  3. Select Rotation Direction: Use the 'FWD./REV.' switch to select the forward or reverse rotation direction for the handpiece. Change direction only when the handpiece is stopped or at very low speed to prevent damage.
  4. Activate Handpiece:
    • If using the foot pedal, press the foot pedal to start the handpiece rotation. Release to stop.
    • If not using the foot pedal, the handpiece will start rotating immediately upon turning the main power switch 'ON' and setting the speed.
  5. Built-in Bur Holder: The control unit features a built-in bur holder for convenient storage of frequently used burs.
  6. Power Off: After use, turn the 'ON/OFF' switch to the 'OFF' position and unplug the unit from the power outlet.

6. Maintenance

  • Cleaning: Wipe the control unit and handpiece with a soft, dry cloth. Do not use harsh chemicals or abrasive cleaners.
  • Handpiece Care: Regularly check the handpiece chuck for debris. Ensure the chuck mechanism operates smoothly. Avoid dropping the handpiece.
  • Fuse Replacement: If the unit fails to power on, check the fuse located at the rear of the control unit (refer to Image 4.1). To replace, unscrew the fuse cap, remove the old fuse, and insert a new fuse of the same rating (typically 2A, 250V).
  • Carbon Brushes: The handpiece uses carbon brushes which may require periodic replacement. Refer to Image 4.2 for the location of replacement carbon brushes. Consult a qualified technician for brush replacement if you are unsure.

7. Troubleshooting

ProblemPossible CauseSolution
Unit does not power on.No power supply; Blown fuse; Loose connection.Check power cord connection; Verify outlet functionality; Replace fuse (see Maintenance section).
Handpiece does not rotate.Handpiece not connected properly; Speed dial set to minimum; Foot pedal not pressed (if in use); Worn carbon brushes.Ensure handpiece cable is securely connected; Increase speed setting; Press foot pedal; Consider carbon brush replacement.
Bur cannot be inserted or removed.Chuck mechanism jammed or overtightened.Ensure handpiece is off; Gently rotate chuck counter-clockwise; Use chuck wrench carefully if needed. Do not force.
Excessive vibration or noise.Bent or unbalanced bur; Loose bur; Internal issue.Check bur for damage and replace if necessary; Ensure bur is securely tightened in the chuck; If problem persists, discontinue use and contact support.

8. Specifications

  • Brand: Smiledt
  • Model Number: mo1052
  • Voltage: 110 Volts
  • Power Source: Corded Electric
  • Maximum Rotational Speed: 35,000 RPM
  • Handpiece Type: Marathon H37SN
  • Chuck Size: 3/32" for HP shank burs
  • Special Features: Compact, Portable, Forward/Reverse rotation, On/Off foot pedal, Built-in bur holder
  • Manufacturer: Saeyang, Korea

9. Warranty and Support

Specific warranty details are not provided in this manual. For warranty information, technical support, or service inquiries, please contact your original retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.