Novitas 01-BAS300

Novitas 01-BAS300 Super Dual Tech Occupancy Sensor Instruction Manual

Automatic Lighting Control for Wall and Ceiling Mount Applications

1. Introduction

This manual provides essential information for the proper installation, operation, and maintenance of the Novitas 01-BAS300 Super Dual Tech Occupancy Sensor. This device is designed to provide automatic lighting control by detecting occupancy in a given area, contributing to energy efficiency.

2. Safety Information

WARNING: Risk of Electric Shock. Installation and servicing must be performed by qualified personnel only. Disconnect power at the circuit breaker or fuse before installing or servicing.

  • Read all instructions carefully before installation.
  • Ensure all wiring connections are secure and comply with local and national electrical codes.
  • Do not install in locations where temperatures or humidity exceed specified limits.
  • This device is intended for indoor use only.

3. Product Overview

The Novitas 01-BAS300 is a Super Dual Tech Occupancy Sensor, utilizing two detection technologies (typically Passive Infrared and Ultrasonic) to accurately sense human presence. This two-way sensor is designed for automatic lighting control, turning lights on when occupancy is detected and off after a period of no detection. It is suitable for both wall and ceiling mount applications.

Novitas 01-BAS300 Super Dual Tech Sensor product box

Figure 1: Packaging for the Novitas 01-BAS300 Super Dual Tech Sensor. The box indicates 'Automatic Lighting Control' and highlights Model 01-BAS300 as a 'Super Dual Tech Sensor (Two-Way)'.

4. Setup and Installation

The 01-BAS300 sensor can be mounted on a wall or ceiling. Proper placement is crucial for optimal performance.

4.1 Mounting Location Considerations

  • Avoid mounting near heat sources (e.g., HVAC vents, incandescent lights) that could cause false triggers.
  • Avoid mounting in direct sunlight or areas with significant air currents.
  • Ensure a clear line of sight for the Passive Infrared (PIR) component and minimal obstructions for the Ultrasonic component.

4.2 Wiring Instructions

Note: All wiring must be performed with power disconnected at the circuit breaker. Consult a qualified electrician if you are unsure about any wiring procedures.

  1. Turn off power to the circuit at the main service panel.
  2. Connect the sensor's wires to the appropriate building wiring (Line, Load, Neutral, Ground) according to the wiring diagram provided with the product packaging.
  3. Secure all wire connections with approved wire connectors.
  4. Mount the sensor securely to the wall or ceiling using the provided hardware.
  5. Restore power and test the sensor's functionality.

5. Operating Instructions

The Novitas 01-BAS300 sensor provides automatic lighting control. Upon initial power-up, the sensor will typically enter a warm-up period (usually 30-60 seconds) during which it may cycle lights on and off. After the warm-up, the sensor will begin normal operation.

5.1 Automatic Operation

  • When occupancy is detected, the connected lights will turn on.
  • The lights will remain on as long as occupancy is continuously detected.
  • After the detected area becomes vacant, the lights will remain on for a pre-set time delay before turning off automatically.

5.2 Adjustments (if applicable)

Depending on the specific model and configuration, the sensor may have adjustable settings for:

  • Time Delay: The duration lights remain on after the last detected motion.
  • Sensitivity: The level of motion required to trigger the sensor.
  • Light Level Sensor (Photocell): To prevent lights from turning on if ambient light is sufficient.

Refer to the detailed instructions included in the product packaging for specific adjustment procedures for your 01-BAS300 model.

6. Maintenance

The Novitas 01-BAS300 sensor requires minimal maintenance to ensure continued optimal performance.

  • Cleaning: Periodically wipe the sensor lens with a soft, dry cloth to remove dust or debris. Do not use abrasive cleaners or solvents.
  • Inspection: Annually inspect the sensor for any physical damage or loose connections.

7. Troubleshooting

If the sensor is not functioning as expected, refer to the following common issues and solutions:

ProblemPossible CauseSolution
Lights do not turn on.No power; faulty wiring; sensor malfunction; ambient light too high (if photocell enabled).Check circuit breaker; verify wiring connections; test sensor; adjust photocell setting.
Lights remain on.Continuous occupancy detected; time delay set too long; sensor malfunction.Ensure area is vacant; adjust time delay; reposition sensor to avoid false triggers.
Lights turn on/off randomly.False triggers from heat sources, air currents, or external motion; sensitivity too high.Relocate sensor; reduce sensitivity; eliminate sources of false triggers.

If troubleshooting steps do not resolve the issue, contact Novitas customer support or a qualified electrician.

8. Specifications

FeatureDetail
Model Number01-BAS300
BrandNovitas
Sensor TypeSuper Dual Tech (Two-Way) Occupancy Sensor
Mounting TypeWall Mount, Ceiling Mount
Power SourceCorded Electric
ColorWhite
Item WeightApproximately 16 ounces (1 pound)
Product DimensionsApproximately 11 x 9 x 6 inches
UPC642337957307

9. Warranty Information

For detailed warranty information regarding your Novitas 01-BAS300 Super Dual Tech Occupancy Sensor, please refer to the documentation included with your product or visit the official Novitas website. Warranty terms typically cover defects in materials and workmanship for a specified period from the date of purchase.

10. Support

If you require further assistance or have questions not covered in this manual, please contact Novitas customer support. You can typically find contact information, including phone numbers and email addresses, on the manufacturer's official website or within the product packaging.

Novitas Official Website: www.cooperlighting.com/brands/novitas

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.