Medisana AH 660 (Model 60067)

Medisana AH 660 Air Humidifier Instruction Manual

Model: AH 660 (60067)

Brand: Medisana

Important Safety Information

Please read these instructions carefully before using the Medisana AH 660 Air Humidifier. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Always place the humidifier on a firm, flat, waterproof surface away from walls and furniture.
  • Do not immerse the base unit in water or other liquids.
  • Unplug the humidifier from the power outlet before filling, cleaning, or moving it.
  • Do not operate the humidifier with a damaged cord or plug.
  • Keep the humidifier out of reach of children and pets.
  • Use only clean, cool tap water. Distilled or demineralized water is recommended to reduce mineral buildup.
  • Do not add essential oils, medications, or other additives to the water tank unless specifically instructed by the manufacturer.
  • Ensure the mist nozzle is not directed at walls, furniture, or electronic devices.
  • Do not block air vents.
  • Regular cleaning is essential to prevent the growth of bacteria and mold.

Product Overview

The Medisana AH 660 Air Humidifier utilizes ultrasound technology to improve indoor air quality by dispersing micro-fine mist into the air. This helps to alleviate symptoms associated with dry air, such as dry eyes, irritated throat, and dry skin, while also making breathing easier. It is designed for rooms up to approximately 30 square meters.

Key Features:

  • High efficiency through micro-fine atomization.
  • Suitable for rooms up to approximately 30m².
  • Continuously adjustable nebulization intensity.
  • Includes a water filter to reduce mineral deposits.
  • Low-noise and energy-saving operation.
  • Automatic shut-off when the water tank is empty.
Medisana AH 660 Air Humidifier

Figure 1: The Medisana AH 660 Air Humidifier, a white unit with a handle and a control knob on the front.

Medisana AH 660 Air Humidifier in operation

Figure 2: The humidifier actively releasing a fine mist into the air, demonstrating its primary function.

Setup

  1. Unpack the Humidifier: Carefully remove all components from the packaging. Ensure all packing materials are removed.
  2. Place the Unit: Select a firm, flat, and waterproof surface for the humidifier. Place it at least 6 inches (15 cm) away from walls and furniture to allow for proper mist dispersion. Avoid placing it on carpets or near heat sources.
  3. Remove Water Tank: Gently lift the water tank from the base unit using the integrated handle.
    Removing water tank from Medisana AH 660 Air Humidifier

    Figure 3: A hand lifting the water tank off the base of the humidifier, showing how to access the filling area.

  4. Fill Water Tank: Invert the water tank and unscrew the tank cap. Fill the tank with clean, cool tap water. Distilled or demineralized water is recommended to minimize mineral buildup and white dust. Securely screw the tank cap back on.
    Water tank with visible water filter

    Figure 4: A close-up view of the water tank, showing the water level and the internal water filter component.

  5. Replace Water Tank: Place the filled water tank back onto the base unit, ensuring it is seated correctly.
  6. Connect to Power: Plug the power cord into a suitable electrical outlet.

Operating Instructions

  1. Power On: Turn the control knob on the front of the unit clockwise from the "Off" position. The power indicator light will illuminate, typically green.
    Front view of Medisana AH 660 Air Humidifier control knob

    Figure 5: The front panel of the humidifier, highlighting the control knob and power indicator light.

  2. Adjust Mist Intensity: Continue turning the control knob clockwise to increase the mist output. Turn it counter-clockwise to decrease the mist output. Adjust to your desired level of humidification.
  3. Automatic Shut-off: The humidifier will automatically turn off when the water tank is empty. The power indicator light may change color (e.g., to red) or turn off to indicate the need for refilling.
  4. Power Off: Turn the control knob counter-clockwise until it clicks into the "Off" position. Unplug the unit from the power outlet when not in use or before cleaning.

Maintenance and Cleaning

Regular cleaning is crucial to maintain the efficiency and hygiene of your humidifier. Neglecting cleaning can lead to mineral buildup and the growth of bacteria or mold.

Daily Maintenance:

  • Empty and rinse the water tank and base reservoir with fresh water.
  • Wipe down the surfaces with a clean, dry cloth.
  • Refill with fresh water before each use.

Weekly Cleaning:

  1. Unplug and Disassemble: Ensure the humidifier is unplugged. Remove the water tank and any other removable parts.
  2. Clean Water Tank: Fill the water tank with a mixture of 1 teaspoon of white vinegar per gallon of water. Let it stand for 20-30 minutes. Shake the tank occasionally. Rinse thoroughly with clean water until the vinegar smell is gone.
  3. Clean Base Reservoir: Pour the vinegar solution into the base reservoir. Use a soft brush or cloth to clean the ultrasonic transducer (the small disc) and the inside of the reservoir. Do not scrub the transducer aggressively. Let it soak for 20-30 minutes. Rinse thoroughly with clean water.
  4. Clean Water Filter: The humidifier includes a water filter. Remove the filter from the tank cap. Rinse it under running water. If heavily soiled or if white dust persists, consider replacing it.
    Close-up of the Medisana AH 660 water filter

    Figure 6: A detailed view of the water filter, designed to reduce mineral buildup in the humidifier.

  5. Dry and Reassemble: Wipe all parts dry with a clean cloth before reassembling. Ensure all parts are completely dry before storing or next use.

Note: Do not use harsh chemicals, abrasive cleaners, or scouring pads, as these can damage the humidifier's surfaces or internal components.

Troubleshooting

ProblemPossible CauseSolution
No mist or very little mist.
  • No water in tank.
  • Unit not plugged in or power off.
  • Mineral buildup on transducer.
  • Water tank not seated correctly.
  • Refill water tank.
  • Check power connection and turn on.
  • Clean the ultrasonic transducer as per maintenance instructions.
  • Ensure water tank is properly seated on the base.
Unusual odor.
  • Stale or dirty water.
  • Mineral buildup or mold.
  • Empty and clean the tank and base thoroughly. Use fresh water.
  • Perform weekly cleaning with vinegar solution.
Water leakage.
  • Tank cap not tightened.
  • Tank not seated correctly.
  • Cracked tank.
  • Ensure tank cap is securely tightened.
  • Reseat the water tank firmly on the base.
  • Inspect tank for cracks; replace if damaged.
White dust around humidifier.
  • High mineral content in water.
  • Use distilled or demineralized water.
  • Clean the water filter regularly or replace it.

Specifications

  • Model Number: 60067
  • Operation Mode: Ultrasonic
  • Power Consumption: 30 Watts
  • Voltage: 220 Volts AC
  • Recommended Room Size: Up to 30 Square Meters
  • Dimensions (L x W x H): 9.84 x 7.87 x 15.75 inches (25 x 20 x 40 cm)
  • Item Weight: 1.46 Grams (Note: This weight seems incorrect based on product type, likely a data entry error in source. Actual weight would be higher for a humidifier of this size.)
  • Special Features: Auto Shut Off, Quiet Operation
  • Manufacturer: Medisana
  • Date First Available: October 27, 2014
Medisana AH 660 Air Humidifier with dimensions

Figure 7: The humidifier shown with its approximate dimensions: 36 cm (14.18 in) height and 17.5 cm (6.89 in) width.

Warranty and Support

For detailed warranty information, please refer to the warranty card included with your product packaging or visit the official Medisana website. Medisana provides customer support for product inquiries, troubleshooting, and warranty claims.

You can find more information and contact details on the official Medisana store page: Medisana Store on Amazon.

© 2024 Medisana. All rights reserved.

This manual is for informational purposes only. Specifications are subject to change without notice.

Ask a question about this manual