1. Introduction

The Safe T Alert 30 Series Flush Mount Propane/LP Gas Alarm is designed to provide reliable detection of propane leaks in recreational vehicles (RVs). This alarm is suitable for Class A, B, and C Motorhomes, Travel Trailers, Fifth Wheels, and Campers. It is engineered for seamless replacement of most CCI Controls LP Gas Leak Detectors, often without requiring rewiring or modifications. The unit operates on 12V DC power, eliminating the need for batteries and conserving power through energy-efficient circuitry. It features a long-lasting, self-cleaning sensor and an 85 dB alarm for consistent safety. This product meets RVIA/NFPA standards and conforms to UL STD 1484 RV, with performance tested across a wide temperature range from -40°F to +158°F.

2. Safety Information

WARNING: This alarm will not operate without power. Ensure the green light is on. Do not connect to a wall switch-controlled outlet. Disconnect power before installing or servicing. Read the entire owner's manual before installation and operation.

  • This device is designed to detect LP gas. It is not designed to detect smoke, carbon monoxide, or other gases.
  • Regularly test the alarm using the Test/Mute button.
  • Do not paint the alarm. Painting may interfere with the sensor's operation.
  • Ensure proper ventilation when the alarm sounds.
  • The alarm has a limited lifespan and must be replaced approximately 60 months (5 years) after the date of manufacture or installation. Refer to the "Replace By" date on the unit.

3. Product Features

  • LP Gas Detection: Specifically designed to detect propane (LP) gas leaks.
  • Flush Mount Design: Integrates seamlessly into RV interiors.
  • 12V DC Operation: Connects directly to the RV's 12-volt power system, no batteries required.
  • Test/Mute Button: Allows for easy testing of all detector functions and temporarily mutes the alarm during ventilation.
  • Rapid Recovery Sensor: Reactivates the alarm if dangerous propane levels persist after muting.
  • Energy-Efficient Circuitry: Conserves power during operation.
  • Self-Cleaning Sensor: Ensures long-lasting and consistent performance.
  • Loud Audible Alarm: 85 dB alarm to alert occupants of gas presence.
  • RVIA/NFPA Compliant: Meets industry safety standards.
  • UL Listed: Certified for RVs and unconditioned areas.

4. Setup and Installation

The Safe T Alert 30-442-P-BL is designed for flush mounting. It is often a direct replacement for existing CCI Controls LP Gas Leak Detectors. Ensure the installation location is appropriate for LP gas detection, typically low to the floor as propane is heavier than air.

Safe T Alert Classic LP Gas Alarm, front view

Figure 1: Front view of the Safe T Alert Classic LP Gas Alarm (Model 30-442-P-BL).

Installation Steps:

  1. Disconnect Power: Before beginning installation, ensure all 12V DC power to the RV is disconnected to prevent electrical shock or damage.
  2. Remove Old Unit (if applicable): If replacing an existing alarm, carefully remove it from its mounting location. Note the wiring connections.
  3. Wiring: The alarm operates on 12V DC. Connect the alarm's wires to the RV's 12V power supply. Typically, the red wire connects to the positive (+) 12V DC supply, and the black wire connects to the negative (-) 12V DC ground. Note: Some units may come with bare wires, requiring splicing to existing connectors or direct wiring.
  4. Mounting: Secure the alarm into the flush-mount opening. Ensure it is firmly seated.
  5. Restore Power: Reconnect the 12V DC power to the RV.
  6. Initial Power-Up: Upon initial power-up, the alarm will perform a self-test. The green LED should illuminate, indicating proper operation.
  7. Test Functionality: Press and hold the Test/Mute button to verify the alarm sounds.
Back view of Safe T Alert Classic LP Gas Alarm with wiring and warning labels

Figure 2: Rear view of the Safe T Alert Classic LP Gas Alarm, showing wiring and important labels including the "Replace By" date and power requirements.

5. Operating Instructions

LED Indicators:

  • Green LED On: Normal operation.
  • Red LED On: LP Gas detected, alarm sounding.
  • Red/Green Flashing (simultaneously): Fault or Low Voltage condition.
  • Red/Green Flashing (alternating): End of Life signal. The unit needs replacement. Resetting the unit will silence the End of Life signal for 3 days, but the unit must be replaced. The mute function will not operate after 30 days of an End of Life signal.

Test/Mute Button:

  • Test Function: Press and hold the button briefly to test the alarm's functionality. The alarm will sound, and the red LED will illuminate.
  • Mute Function: If the alarm sounds due to LP gas detection, pressing the Test/Mute button will temporarily silence the alarm for a few minutes to allow for ventilation. The alarm remains fully operational during the mute cycle and will re-alarm if hazardous conditions persist or recur.

6. Maintenance

  • Regular Testing: Test the alarm weekly or before each trip by pressing the Test/Mute button.
  • Cleaning: Keep the alarm free from dust and debris. Gently wipe the exterior with a damp cloth. Do not use cleaning agents or paint the unit.
  • Sensor Life: The alarm features a self-cleaning sensor designed for long life. However, all gas sensors have a limited operational lifespan. This unit must be replaced approximately 60 months (5 years) after the date of manufacture or installation. Refer to the "Replace By" date printed on the unit.

7. Troubleshooting

ProblemPossible CauseSolution
Alarm sounds (Red LED on)LP Gas leak detected.
  1. Immediately open all windows and doors for ventilation.
  2. Turn off all gas appliances.
  3. If possible, turn off the main LP gas supply.
  4. Evacuate the RV.
  5. Do not re-enter until the alarm has silenced and the area is thoroughly ventilated.
  6. Have the LP gas system inspected by a qualified technician.
Red/Green LEDs flashing (alternating)End of Life signal.The alarm has reached the end of its operational life. Replace the unit immediately.
Red/Green LEDs flashing (simultaneously)Fault condition or low voltage.
  1. Check the RV's 12V DC power supply to ensure it is within operating voltage.
  2. If voltage is normal, the unit may have an internal fault. Replace the unit.
Alarm does not sound during testNo power, faulty unit, or wiring issue.
  1. Verify 12V DC power is supplied to the unit (green LED should be on).
  2. Check wiring connections.
  3. If power is present and wiring is correct, the unit may be faulty and requires replacement.

8. Specifications

Model Number30-442-P-BL
Power Source12V DC
Current Draw90 mA
Sensor TypePropane (LP Gas)
Alarm Loudness85 dB at 10 feet
Operating Temperature-40°F to +158°F (-40°C to +70°C)
Operating Humidity95% RH non-condensing
Dimensions1.75"D x 10"W x 8"H
Item Weight0.28 Pounds (4.5 ounces)
Replacement Interval60 months (5 years) after retail sale/installation
CertificationsUL STD 1484 RV, RVIA/NFPA Compliant

9. Warranty and Support

This Safe T Alert LP Gas Alarm comes with a one-year limited warranty from the date of purchase. For warranty claims or technical support, please refer to the contact information provided by the manufacturer, MTI Industries, or your retailer. Keep your proof of purchase for warranty purposes.

Manufacturer: MTI Industries

© 2025 Safe T Alert. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.