Lightolier ITSRB3W

Lightolier ITSRB3W Intellisight 3-Way Remote Occupancy Sensor Switch Instruction Manual

1. Introduction and Overview

The Lightolier ITSRB3W is a 3-way remote switch designed for use with Lightolier ITS2U Occupancy Sensor Switches. This device provides remote ON and OFF operations in multi-location lighting applications. It is compatible with both 120V and 277V electrical installations and features a decorator-style design. Proper functionality requires a ground connection.

Lightolier ITSRB3W Intellisight 3-Way Remote Occupancy Sensor Switch with faceplate

Image: The Lightolier ITSRB3W Intellisight 3-Way Remote Occupancy Sensor Switch, shown with its white decorator-style faceplate. This image illustrates the physical appearance of the product.

2. Safety Information

WARNING: Risk of Electric Shock. Improper installation may result in serious injury or death. Always turn off power at the circuit breaker or fuse box before beginning any installation, wiring, or maintenance procedures. All wiring must be performed by a qualified electrician in strict accordance with national and local electrical codes and regulations.

Ensure proper grounding. This device requires a ground connection for safe and correct operation. Do not install this switch without a ground wire.

3. Package Contents

Verify that your package contains the following items:

4. Setup and Installation

This remote switch is intended for use in conjunction with a Lightolier ITS2U Occupancy Sensor Switch in a 3-way wiring configuration. Refer to the ITS2U Occupancy Sensor Switch manual for detailed wiring diagrams and complete installation instructions for the primary sensor.

  1. Step 1: Power Disconnection. Locate the circuit breaker or fuse box that controls the power to the switch location. Turn off the power completely to prevent electrical shock. Verify power is off using a voltage tester.
  2. Step 2: Wiring Identification. Carefully remove the existing switch (if any) from the wall box. Identify the line (hot), load, traveler, and ground wires. The ITSRB3W requires a ground connection.
  3. Step 3: Wiring Connections. Connect the wires from the wall box to the ITSRB3W remote switch terminals. Ensure all connections are secure and made according to the wiring diagram provided with your ITS2U Occupancy Sensor Switch. This is a 3-way remote, so ensure proper traveler wire connections between the ITSRB3W and the ITS2U sensor.
  4. Step 4: Mounting. Gently push the wired ITSRB3W switch into the wall box. Secure the switch to the wall box using the provided mounting screws. Attach the decorator-style faceplate.
  5. Step 5: Power Restoration. Once installation is complete and all connections are secure, restore power at the circuit breaker. Test the functionality of the remote switch in conjunction with the ITS2U sensor.

5. Operating Instructions

The Lightolier ITSRB3W functions as a remote ON/OFF control for the connected ITS2U Occupancy Sensor Switch. It does not contain its own occupancy sensing capabilities.

The primary occupancy sensing, time delay, and sensitivity settings are controlled by the main ITS2U Occupancy Sensor Switch. Refer to the ITS2U manual for adjustments to these functions.

6. Maintenance

The Lightolier ITSRB3W remote switch requires minimal maintenance.

7. Troubleshooting

ProblemPossible CauseSolution
Lights do not turn ON/OFF from the ITSRB3W remote switch.No power to the circuit.
Loose or incorrect wiring connections.
Main ITS2U Occupancy Sensor Switch malfunction.
Check power at the circuit breaker and ensure it is ON.
Turn off power, then verify all wiring connections (line, load, ground, traveler) are secure and correct according to the ITS2U manual.
Refer to the troubleshooting section of the ITS2U Occupancy Sensor Switch manual.
Intermittent operation or unreliable control.Loose wiring connections.
Interference (if Wi-Fi connectivity is active).
Turn off power, then check and tighten all wiring connections.
Ensure the remote switch is within range of the main sensor or Wi-Fi network if applicable. Consult the ITS2U manual for specific pairing or connectivity instructions.

8. Specifications

FeatureSpecification
BrandLightolier
ModelITSRB3W
Operating Voltage120V / 277V
Circuit Type3-way
Control MethodRemote
Mounting TypePanel Mount
Dimensions (L x W x H)4.5 x 3 x 2 inches
ColorWhite
International Protection RatingIP67
Connectivity ProtocolWi-Fi (Note: This may refer to connectivity features of the main ITS2U sensor or advanced integration capabilities.)

9. Warranty and Support

For detailed warranty information, technical assistance, or customer support regarding your Lightolier ITSRB3W Intellisight 3-Way Remote Occupancy Sensor Switch, please contact Lightolier customer service directly. You may also visit the official Lightolier website for product resources and contact details. Please retain your purchase receipt as proof of purchase for any warranty claims.

Related Documents - ITSRB3W

PreviewCalculite LED Accessories: Emergency Battery Pack Installation Guide (IS_CAEM6)
Step-by-step installation instructions for Lightolier's Calculite LED Accessories emergency battery pack (model IS_CAEM6), including wiring and test switch mounting.
PreviewLightolier Calculite LED 4" gen 3 C4RA Round AirsSeal IC Frame Downlighting
Detailed specifications, ordering information, technical data, and control system features for the Lightolier Calculite LED 4" gen 3 C4RA Round AirsSeal IC Frame downlighting fixture.
PreviewLightolier Calculite LED 3" C3RWW Round Wall Wash Downlight Specification Sheet
Detailed specification sheet for the Lightolier Calculite LED 3" C3RWW round wall wash downlight, covering features, ordering information, technical specifications, dimming options, controls, and photometric data.
PreviewLightolier Calculite LED 6" Gen 3 C6SLW Square Wall Wash - Product Specifications
Discover the Lightolier Calculite LED 6" Gen 3 (C6SLW) Square Wall Wash luminaire, designed for superior performance, visual comfort, and installation flexibility in commercial spaces. Learn about BAA compliance and Interact smart lighting integration.
PreviewLightolier IS-RD_R LED Retrofit Downlight Installation Instructions
Detailed installation and removal instructions for the Lightolier IS-RD_R LED Retrofit Downlight, including safety warnings, compliance information, and dimensional requirements for recessed housings.
PreviewLightolier IS:1005 Installation Instructions for Lytecaster Reflector Trim
Detailed installation guide for Lightolier Lytecaster Reflector Trim in 1000 Series Frame-In Kits, covering various models and steps. Includes safety warnings, product specifications, and assembly procedures.