1. Introduction
The Pyle PS900 Audio/Video AC Power Conditioner is designed to provide clean, filtered power to your audio and video equipment. It features advanced circuitry to eliminate noise and interference, protect against voltage fluctuations, and offer sequential power-up/down capabilities for connected devices. This manual provides essential information for the safe and efficient use of your PS900 unit.
2. Important Safety Instructions
- Read all instructions: Before operating the unit, read and understand all safety and operating instructions.
- Retain instructions: Keep this manual for future reference.
- Heed warnings: Follow all warnings on the unit and in the operating instructions.
- Unplug before cleaning: Always unplug the unit from the power outlet before cleaning. Use a damp cloth for cleaning; do not use liquid or aerosol cleaners.
- Power sources: Connect the unit only to the type of power source described in the operating instructions or marked on the unit.
- Power cord protection: Route power supply cords so that they are not likely to be walked on or pinched by items placed upon or against them.
- Overloading: Do not overload wall outlets or extension cords as this can result in a risk of fire or electric shock.
- Ventilation: Ensure proper ventilation. Do not block any ventilation openings.
- Water and moisture: Do not use this unit near water (e.g., bathtub, sink, wet basement, swimming pool).
- Servicing: Do not attempt to service this product yourself as opening or removing covers may expose you to dangerous voltage or other hazards. Refer all servicing to qualified service personnel.
3. Key Features
- Clean Filtered AC Power: Features 2-Stage High Insert Dissipation for optimal power delivery.
- Micro-Controller: Ensures precise timing for sequential operations.
- EMI Filter: Built-in 2-Stage EMI Filter for each rear output to reduce electromagnetic interference.
- Automatic Master Unit Display: Capable of linking over 100 units in series.
- Real-Time Monitoring: Monitors AC voltage, ambient temperature, and step time.
- Output Control: Individual output cut switch for all nine channels.
- Status Indicators: LED displays for Output Cut, Master, Bypass, Power, AC Voltage, and Temperature.
- Rack-Mountable Design: Standard 1U rack-mountable chassis for professional installations.
- Multiple Outlets: Includes 2 front-panel outlets and 8 rear-panel outlets.
4. Setup Guide
4.1 Unpacking and Inspection
Carefully remove the Pyle PS900 from its packaging. Inspect the unit for any signs of damage during transit. Ensure all components listed in the "What's in the Box" section are present.

Image: Contents of the Pyle PS900 box, showing the power conditioner unit and a control signal link cable.
4.2 Placement and Mounting
The PS900 is designed for standard 1U rack mounting. Secure the unit into a 19-inch equipment rack using appropriate rack screws (not included). Ensure adequate ventilation around the unit to prevent overheating. Alternatively, the unit can be placed on a flat, stable surface, utilizing its rubber feet for stability.

Image: Pyle PS900 power conditioner installed in a standard equipment rack, demonstrating its rack-mountable design.
4.3 Connecting to Power
Connect the heavy-duty power cord from the PS900's rear panel to a grounded AC power outlet. Ensure the power outlet provides the correct voltage (120V AC, 60Hz for North American models). The unit features a robust power cord designed for reliable connection.

Image: Detailed view of the Pyle PS900's rear panel, highlighting the power input and eight sequenced output sockets.
4.4 Connecting Equipment
Plug your audio/video equipment into the outlets on the PS900. The unit provides 2 outlets on the front panel and 8 sequenced outlets on the rear panel. For optimal performance and protection, distribute your equipment across the available outlets. The sequencing feature allows for controlled power-up and power-down of connected devices, preventing sudden power surges that can damage sensitive electronics.
5. Operating Instructions
5.1 Powering On/Off
To power on the unit, press the main POWER switch located on the front panel. The unit will initiate its power sequencing, turning on each of the 8 rear outlets in a timed sequence. The front outlets are typically unswitched or can be controlled independently. To power off, press the POWER switch again; the unit will power down the outlets in reverse sequence.

Image: Front panel of the Pyle PS900, showing the main power switch, voltage display, and individual channel indicators.
5.2 Monitoring Display
The front panel features an LED display that shows real-time AC voltage, ambient temperature, and step time. This allows you to monitor the power status and environmental conditions affecting your equipment.
5.3 Bypass Function
The PS900 includes a Bypass function. When activated, this function allows all outlets to power on or off simultaneously, bypassing the sequential power-up/down feature. Refer to the front panel controls for the Bypass button.
5.4 Series Linking (Master/Slave)
For larger setups, multiple PS900 units can be linked in series using the Control Signal Link ports on the rear panel. This allows a single master unit to control the power sequencing of up to 100 slave units, ensuring synchronized power management across all connected equipment.
Video: Demonstration of a power sequencer with individual channel control and real-time voltage display, similar to the PS900's functionality. This video is provided by MICNAUX AUDIO.
Video: Comparison of power sequencers, highlighting the convenience of individual control buttons for each channel, a feature also present in the PS900. This video is provided by FULODE Official Shop.
6. Maintenance
- Cleaning: Disconnect power before cleaning. Use a soft, dry cloth to wipe the exterior of the unit. Avoid abrasive cleaners or solvents.
- Ventilation: Regularly check that the ventilation openings are clear of dust and debris to ensure proper airflow and prevent overheating.
- Cable Connections: Periodically inspect all power cords and connected cables for any signs of wear, fraying, or damage. Replace damaged cables immediately.
- Circuit Breaker: The unit may include a resettable circuit breaker. If an overload occurs, the breaker will trip to protect connected equipment. Disconnect some devices, then reset the breaker.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| No power to unit or outlets. | Unit is not plugged in; main power switch is off; circuit breaker tripped. | Ensure power cord is securely plugged into a live outlet. Turn the main POWER switch ON. Check and reset the circuit breaker if tripped. |
| Equipment not powering on in sequence. | Bypass function is active; individual channel switch is off; control cable issue (for linked units). | Deactivate the Bypass function. Ensure individual channel switches are in the correct position. Check the control signal link cable for secure connection. |
| Unusual noise or interference. | Ground loop; external electromagnetic interference. | Ensure all equipment is properly grounded. Check for other devices causing interference. The PS900's EMI filter should mitigate most issues. |
| Voltage display shows abnormal readings. | Input voltage fluctuation; unit malfunction. | Verify the wall outlet voltage with a separate meter. If readings are consistently abnormal and not fluctuating, contact customer support. |
8. Technical Specifications
- Model: PS900
- Input Voltage: AC 120V, 60Hz (Standard North American)
- Output Outlets: 2 Front (Unswitched), 8 Rear (Sequenced)
- Total Outlets: 10
- Power Capacity: 1200 Watts (Maximum Output)
- Protection: Surge Protection, EMI/RFI Filtering, Extreme Voltage Shutdown
- Display: LED for AC Voltage, Temperature, Step Time, Output Status
- Mounting: 1U Rack-Mountable (19-inch standard)
- Dimensions (L x W x H): Approximately 19.0'' x 8.0'' x 1.75'' (Standard 1U Rack Size) (Note: Product dimensions from specifications were inconsistent with typical 1U rack units and visual representation. Standard 1U rack dimensions are used here.)
- Weight: 5 lbs (2.27 kg)
- Color: Black
- UPC: 068888750769
9. Warranty and Support
9.1 Limited Warranty
Pyle products are warranted against defects in materials and workmanship for a period of one (1) year from the date of original purchase. This warranty does not cover damage caused by accident, misuse, abuse, improper installation or operation, lack of reasonable care, unauthorized modification, or the use of unauthorized replacement parts. The warranty is void if the product has been tampered with or repaired by unauthorized persons.
For warranty service, please contact Pyle customer support with your proof of purchase.
9.2 Customer Support
For technical assistance, product information, or warranty inquiries, please visit the official Pyle website or contact their customer service department. Contact information can typically be found on the product packaging or the Pyle USA website.
Pyle USA Website: www.pyleusa.com