1. Introduction
This manual provides comprehensive instructions for the safe installation, operation, and maintenance of your SIDLER Axara AX 2/120 FL 2 FL T5 21W white fluorescent light fixture. Please read this manual thoroughly before installation and retain it for future reference.
The SIDLER Axara AX 2/120 FL 2 FL T5 21W is a high-quality fluorescent light fixture designed for various indoor lighting applications. It features a white finish and utilizes T5 21W fluorescent lamps.

This image displays the SIDLER Axara AX 2/120 FL 2 FL T5 21W white fluorescent light fixture installed above a mirrored cabinet, showcasing its design and typical application.
2. Safety Instructions
Always adhere to the following safety precautions to prevent injury or damage to the product:
- WARNING: Risk of electric shock. Disconnect power at the circuit breaker or fuse box before installation or servicing.
- Installation should be performed by a qualified electrician in accordance with all local and national electrical codes.
- Do not install near heat sources or in areas with excessive moisture.
- Ensure the mounting surface can support the weight of the fixture.
- Do not operate the fixture with damaged wiring or components.
- Use only the specified T5 21W fluorescent lamps.
- Keep packaging materials out of reach of children.
3. Setup and Installation
Professional installation is recommended for this electrical fixture. Ensure all power is disconnected before beginning installation.
3.1. Tools Required (Not Included)
- Screwdriver (Phillips and/or Flathead)
- Wire Strippers
- Drill (if mounting to a new location)
- Measuring Tape
- Pencil
- Safety Glasses
3.2. Installation Steps
- Disconnect Power: Turn off the power at the main circuit breaker or fuse box to the area where the fixture will be installed. Verify power is off using a voltage tester.
- Prepare Mounting Surface: Identify the desired mounting location. Ensure it is a stable surface capable of supporting the fixture's weight. Mark the drilling points for the mounting bracket.
- Install Mounting Bracket: Secure the fixture's mounting bracket to the wall or ceiling using appropriate screws and anchors (if necessary).
- Wiring Connections: Carefully connect the fixture's wires to the household electrical wires. Typically, this involves connecting:
- Black (Live) to Black (Live)
- White (Neutral) to White (Neutral)
- Green or Bare Copper (Ground) to Green or Bare Copper (Ground)
- Mount the Fixture: Carefully attach the light fixture to the installed mounting bracket, ensuring it is securely fastened.
- Install Fluorescent Lamps: Insert the T5 21W fluorescent lamps into the fixture's sockets according to the markings on the fixture. Ensure they are seated correctly.
- Restore Power: Once installation is complete and all connections are secure, restore power at the circuit breaker.
- Test Operation: Turn on the light switch to verify the fixture is working correctly.
4. Operating Instructions
The SIDLER Axara AX 2/120 FL 2 FL T5 21W light fixture is designed for simple operation.
- Turning On/Off: Operate the fixture using the standard wall switch connected to its electrical circuit.
- Lamp Type: This fixture is designed to operate with T5 21W fluorescent lamps. Using other lamp types may damage the fixture or result in improper operation.
5. Maintenance
Regular maintenance ensures optimal performance and longevity of your light fixture.
- Cleaning:
- Always disconnect power before cleaning.
- Wipe the exterior of the fixture with a soft, damp cloth. Do not use abrasive cleaners or solvents.
- Ensure the fixture is completely dry before restoring power.
- Lamp Replacement:
- Disconnect power before replacing lamps.
- Allow lamps to cool before handling.
- Carefully remove the old T5 21W fluorescent lamp by rotating it and pulling it out of the socket.
- Insert the new T5 21W fluorescent lamp, ensuring it is properly seated in the sockets.
- Dispose of old fluorescent lamps according to local regulations.
6. Troubleshooting
If you encounter issues with your light fixture, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Light does not turn on. | No power to the fixture; faulty lamp; loose wiring connection; faulty switch. | Check circuit breaker/fuse. Ensure power is on. Replace lamp. Check wiring connections (with power off). Test or replace switch. |
| Light flickers. | Loose lamp connection; aging lamp; incorrect lamp type; faulty ballast (internal component). | Ensure lamp is securely seated. Replace lamp. Verify correct T5 21W lamp is used. Contact a qualified electrician if ballast is suspected. |
| Light is dim. | Aging lamp; dirty fixture/diffuser. | Replace lamp. Clean the fixture and diffuser. |
If troubleshooting steps do not resolve the issue, contact a qualified electrician or the manufacturer for assistance.
7. Specifications
| Feature | Detail |
|---|---|
| Model Number | 1.112.005 |
| Brand | Sidler |
| Description | Axara AX 2/120 FL 2 FL T5 21W white |
| Manufacturer | Sidler |
| Part Number | 1.112.005 |
| Color | White |
| Item Package Quantity | 1 |
| ASIN | B00H8ZLSOM |
| Date First Available | December 13, 2013 |
8. Warranty and Support
For information regarding warranty coverage, technical support, or replacement parts for your SIDLER Axara AX 2/120 FL 2 FL T5 21W light fixture, please contact Sidler customer service directly. Refer to the product packaging or the official Sidler website for the most current contact information.
Manufacturer: Sidler
Website: www.sidler.ca