1. Introduction
The GAO EMP200S Personal Protection Adapter is designed to enhance electrical safety by preventing potentially fatal electrical accidents. This easy-to-install adapter is suitable for both indoor and outdoor applications, providing an additional layer of protection against electric shock. Please read this manual carefully before installation and use to ensure proper operation and safety.
2. Safety Instructions
- Always ensure the adapter is correctly plugged into a functional protective contact socket.
- Do not use the adapter if it appears damaged.
- This device is rated IP44, indicating protection against solid objects larger than 1mm and splashing water from any direction. When used outdoors or in wet environments, ensure the operating position prevents water accumulation or direct submersion.
- The integrated child safety feature helps prevent accidental insertion of objects into the socket.
- Before each use, perform the test procedure as described in Section 4. Operating Instructions.
- Do not attempt to open or repair the adapter. Refer all servicing to qualified personnel.
- Disconnect power before cleaning or when not in use for extended periods.
3. Product Overview
The GAO EMP200S Personal Protection Adapter is a compact device designed for immediate electrical safety. It features a standard 2-pin EU plug for connection to a wall socket and an integrated protective contact socket for connecting your appliance. Key components include:
- TEST Button (Blue): Used to verify the adapter's functionality.
- RESET Button (Green): Used to restore power after a trip or test.
- Indicator Light: Shows the operational status (if present, typically near the TEST/RESET buttons).
- Protective Contact Socket: For connecting electrical appliances.
- IP44 Rating: Indicates suitability for outdoor use with protection against splashing water.

An image showing the GAO EMP200S Personal Protection Adapter. It features a black casing, a green 'RESET' button, a blue 'TEST' button, and text indicating 'TEST BEFORE USE' and 'OUTDOOR RCD IP44'.
4. Setup
- Inspect the Adapter: Before use, visually inspect the adapter for any signs of damage. Do not use if damaged.
- Plug In: Insert the GAO EMP200S adapter into a standard 230 V / 50 Hz protective contact wall socket.
- Connect Appliance: Plug the electrical appliance you wish to protect into the socket on the GAO EMP200S adapter.
- Perform Test: Always perform the test procedure described in Section 5 before connecting any appliance for the first time or after any power interruption.
5. Operating Instructions
5.1. Initial Activation and Reset
- After plugging the adapter into the wall socket, press the green RESET button. The indicator light (if present) should illuminate, indicating power is supplied to the adapter's output socket.
5.2. Testing the Adapter (TEST BEFORE USE)
It is crucial to test the adapter before each use to ensure it is functioning correctly.
- Ensure the adapter is plugged into the wall socket and the green RESET button has been pressed (power is on).
- Press the blue TEST button. The adapter should immediately trip, and the indicator light should turn off. This simulates an electrical fault and confirms the protection mechanism is active.
- If the adapter does not trip, it is faulty and must not be used. Disconnect it immediately and seek professional advice.
- To restore power after a successful test, press the green RESET button again. The indicator light should illuminate.
5.3. Automatic Shutdown
The adapter is designed for two-pole shutdown. In the event of an electrical fault (e.g., earth leakage current), the adapter will automatically trip, cutting off power to the connected appliance within 30 milliseconds at a switching current of 30 mA. This rapid response helps prevent electric shock.
6. Maintenance
- Cleaning: Disconnect the adapter from the power supply before cleaning. Wipe the exterior with a dry, soft cloth. Do not use abrasive cleaners or solvents.
- Storage: Store the adapter in a dry place, away from direct sunlight and extreme temperatures, when not in use.
- Regular Inspection: Periodically check the adapter and its connected cables for any signs of wear or damage.
7. Troubleshooting
- Adapter does not reset: Ensure it is properly plugged into the wall socket. If it still does not reset after pressing the green RESET button, there might be a fault in the adapter or the connected appliance. Disconnect the appliance and try resetting the adapter alone. If it resets, the appliance may be faulty. If it still doesn't reset, the adapter is faulty.
- Adapter trips immediately after reset: This indicates an electrical fault in the connected appliance or its cable. Disconnect the appliance and have it checked by a qualified electrician.
- Adapter does not trip when TEST button is pressed: The adapter is faulty and does not provide protection. Discontinue use immediately and replace the unit.
8. Specifications
| Feature | Specification |
|---|---|
| Model Number | EMP200S |
| Brand | GAO |
| Input Voltage | 230 V / 50 Hz |
| Max. Connection Power | 3680 W (230 V ~, 16 A) resistive load |
| Switching Current | 30 mA |
| Switching Time | < 30 ms |
| Protection Rating | IP44 |
| Plug Type | Type C - 2 pin EU |
| Product Dimensions (LxWxH) | 9.1 x 6 x 13.2 cm |
| Weight | 220 g |
| Child Safety | Integrated |
9. Warranty and Support
For warranty information or technical support, please refer to the documentation provided with your purchase or contact GAO customer service. Keep your proof of purchase for any warranty claims.