Palintest SP 610

Palintest Pooltester SP 610 Instruction Manual

Model: SP 610

Introduction

This manual provides detailed instructions for the proper use and maintenance of the Palintest Pooltester SP 610. This device is designed for accurate and reliable measurement of chlorine and pH levels in swimming pools, hot tubs, and spas.

Palintest Pooltester SP 610 kit components including blue case, test block, and reagent tablets.

Figure 1: Palintest Pooltester SP 610 kit showing the blue storage case, the transparent test block with color scales, and blister packs of reagent tablets.

Package Contents

Verify that all components are present in your Palintest Pooltester SP 610 kit:

Palintest Pooltester SP 610 kit contents laid out, including the blue case, test block, reagent tablets, and instruction leaflet.

Figure 2: Contents of the Pooltester SP 610 kit, including the blue case, test block, reagent tablets, and instruction leaflet.

Setup

The Palintest Pooltester SP 610 is designed for immediate use with minimal setup. Ensure you have a clean, well-lit area for testing.

  1. Unpack Components: Carefully remove the testing block, reagent tablets, and instruction leaflet from the splash-proof case.
  2. Familiarize Yourself: Review the instruction leaflet provided with the kit to understand the color scales and measurement procedures.
Open blue Palintest Pooltester SP 610 case with the test block partially visible inside.

Figure 3: The blue storage case for the Pooltester SP 610, designed to protect the test block and tablets.

Operating Instructions

Follow these steps for accurate measurement of chlorine and pH levels:

  1. Rinse Test Block: Before each use, rinse the test block thoroughly with the water to be tested.
  2. Fill Test Block: Dip the test block into the pool, spa, or hot tub water to be tested, ensuring both chambers are filled to the marked line. Avoid touching the inside of the chambers.
  3. Add Reagents:
    • For Chlorine (Cl2) measurement (right chamber): Add one DPD1 tablet. Do not touch the tablet with your fingers.
    • For pH measurement (left chamber): Add one Phenol Red pH tablet. Do not touch the tablet with your fingers.
  4. Dissolve Tablets: Place the lid on the test block and gently shake until the tablets are completely dissolved and the color has developed. This usually takes a few seconds.
  5. Read Results: Hold the test block against a white background in good natural light. Compare the color in each chamber with the corresponding color scale on the test block. Read the value that most closely matches the developed color.
    • Chlorine (Cl2) Range: 0.1 - 6.0 mg/l
    • pH Range: 6.8 - 8.2
Close-up of the Palintest Pooltester SP 610 test block showing the pH and chlorine color scales.

Figure 4: The transparent test block with distinct color scales for pH (left) and chlorine (right) measurements.

Maintenance

Proper maintenance ensures the longevity and accuracy of your Pooltester SP 610:

Troubleshooting

ProblemPossible CauseSolution
Inaccurate readingsExpired reagents, contaminated test block, improper tablet dissolution, incorrect water sample.Use fresh reagents. Clean test block thoroughly. Ensure tablets fully dissolve. Collect water sample from appropriate depth away from jets.
Tablets not dissolvingInsufficient shaking, old tablets.Shake the test block more vigorously. Check tablet expiry date and replace if necessary.
Color does not developMissing tablet, incorrect tablet type, expired tablet.Ensure a tablet is added to each chamber. Verify correct tablet type (DPD1 for chlorine, Phenol Red for pH). Use fresh tablets.

Specifications

ParameterValue
Model NumberSP 610
BrandPalintest
Chlorine (Cl2) Measurement Range0.1 - 6.0 mg/l
pH Measurement Range6.8 - 8.2
Product Dimensions1.38 x 3.54 x 1.57 inches
Weight3.53 ounces
Recommended UsesPools, spas, hot tubs, Jacuzzis

Warranty and Support

For information regarding product warranty, technical support, or to purchase additional reagent tablets, please contact Palintest customer service or visit their official website. Refer to the contact details provided in the original product packaging or on the manufacturer's website.

Note: This manual provides general guidance. Always refer to the specific instructions included with your product for the most accurate and up-to-date information.

Related Documents - SP 610

Preview Palintest Kemio User Manual and Test Instructions
A comprehensive guide to using the Palintest Kemio multiparameter water quality testing instrument, detailing procedures for various tests including chlorine, bromine, peracetic acid, chlorine dioxide, chlorite, and heavy metals.
Preview Palintest Kemio Test Instructions
Comprehensive instructions for using the Palintest Kemio multiparameter instrument for various water quality tests, including chlorine, bromine, peracetic acid, chlorine dioxide, chlorite, and heavy metals.
Preview Palintest Total Hardness Water Test: Step-by-Step Instructions & Guide
Detailed instructions for performing a photometric test for Total Hardness in water using Palintest's Hardicol reagents. Learn the simple steps for accurate water analysis of natural, treated, and drinking water.
Preview Kemio User Manual - Palintest Water Analysis Technologies
Comprehensive user manual for the Palintest Kemio, a measurement and data platform for chemical testing. Learn about its features, configuration, performing tests, and maintenance.
Preview Palintest Lumiso Expert Quick Start Guide: Water Analysis Technologies
A concise guide to setting up and using the Palintest Lumiso Expert photometer for accurate water analysis. Learn about registration, getting started, blanking, and best practices.
Preview Palintest Kemio User Manual: Comprehensive Guide to Operation and Features
The official user manual for the Palintest Kemio water quality tester. This guide provides detailed instructions on setup, operation, configuration, maintenance, troubleshooting, and technical specifications for the Kemio device.