Introduction

The Perry 1IO6080 is a single-channel digital daily timer designed for precise control of electrical loads. It features a 2 DIN display with backlighting, allowing for easy programming and monitoring. This timer supports a minimum programming interval of 1 second and includes a power reserve of 15 days to maintain settings during power outages. Its simplified programming interface makes it user-friendly for various applications.

Safety Information

Warning: Electrical installations should only be performed by qualified personnel. Always disconnect the main power supply (230V~) before making any electrical connections to prevent electric shock. Ensure all wiring complies with local electrical codes and regulations. Do not expose the device to moisture or extreme temperatures. This device is designed for indoor use only.

Product Overview

The Perry 1IO6080 digital timer is a compact device designed for DIN rail mounting. It features a clear digital display and intuitive buttons for setting and programming.

Front view of the Perry 1IO6080 Digital Daily Timer

Figure 1: Front view of the Perry 1IO6080 Digital Daily Timer, showing the display and control buttons.

Display and Button Layout

Diagram of the Perry 1IO6080 display and button functions

Figure 2: Detailed view of the timer's display and button functions.

  • Temporary Manual Override (C1): Button for temporary manual switching of channel 1.
  • On/OFF Status (C1): Indicates the current ON or OFF state of channel 1.
  • Channel (C1): Indicates the active channel (this model is single-channel).
  • Settings and/or Displays: Shows current time, ON/OFF times of programs, or permanent manual override status.
  • Days of the Week: (Applicable for weekly models, may show all days for daily timer).
  • Time Setting Buttons: Used to set hours, minutes, and seconds.
  • Day Button (DAY): (Applicable for weekly models).
  • Manual Override Button (C1): For permanent manual ON/OFF control of channel 1.
  • ON Time Indication: Shows the start time of a program.
  • Intervention Indication: Shows duration in seconds.
  • OFF Time Indication: Shows the end time of a program.
  • Program Number (P1 to P20): Indicates the active program slot.
  • OK Button: Confirms settings.
  • PROG Button: Accesses programming mode and allows reading programs.

Installation

Dimensions

Dimensional drawing of the Perry 1IO6080 Digital Daily Timer

Figure 3: Dimensions of the Perry 1IO6080 timer (measurements in mm).

The timer has a width of 35mm, a height of 90mm, and a depth of 60mm, making it suitable for standard 2 DIN rail mounting.

Wiring Instructions

Important: Ensure the main power supply is disconnected before proceeding with wiring.

Wiring diagram for the Perry 1IO6080 Digital Daily Timer

Figure 4: Illustrative wiring diagram for the Perry 1IO6080 timer.

Terminal Description:
  • Mains Power Supply 230V~:
    • Terminal n° 5 = L (Line)
    • Terminal n° 10 = N (Neutral)
  • Relay Channel 1 (Potential-free changeover contact):
    • Terminal n° 1 = NO (Normally Open contact)
    • Terminal n° 2 = C (Common)
    • Terminal n° 3 = NC (Normally Closed contact)

Connect the 230V~ mains power to terminals 5 (Line) and 10 (Neutral). Connect the load to be controlled to the relay contacts (1, 2, 3) as required. For example, to switch a light, connect the common (C) terminal 2 to the live wire, and the normally open (NO) terminal 1 to the light fixture, with the neutral connected directly to the light fixture.

Operating Instructions

Simplified Programming Overview

Simplified programming guide and examples for the Perry 1IO6080

Figure 5: Simplified programming steps and examples.

  • PROGR Button: Press to enter programming mode.
  • P Button: Selects the desired channel (for this model, typically channel 1).
  • DAY Button: Selects the day or group of days for the program (if applicable for daily timer, usually applies to all days).
  • Time Setting Buttons: Use to input ON/OFF times for programs.
  • PROGR Button (again): Press to exit programming mode and save settings.

Setting the Current Time

  1. Ensure the timer is not in programming mode.
  2. Use the dedicated time setting buttons (hour, minute, second) to adjust the current time displayed on the screen.
  3. Press the OK button to confirm the current time.

Programming ON/OFF Cycles

  1. Press the PROGR button to enter programming mode. The display will likely show 'P1' for Program 1.
  2. Use the time setting buttons to set the desired ON time for Program 1.
  3. Press OK to confirm the ON time.
  4. Use the time setting buttons to set the desired OFF time for Program 1.
  5. Press OK to confirm the OFF time.
  6. To add more programs (P2, P3, etc., up to P20), repeat steps 2-5.
  7. After setting all desired programs, press the PROGR button again to exit programming mode. The timer will now operate according to the set schedule.

Manual Override

  • Temporary Manual Override: Use the dedicated button (often labeled with a hand icon or similar) to temporarily switch the output ON or OFF, overriding the current program until the next scheduled event.
  • Permanent Manual Override: Use the manual override button (often labeled 'MANUAL' or similar) to permanently switch the output ON or OFF, disregarding all programs until the override is manually canceled.

Maintenance

The Perry 1IO6080 digital timer requires minimal maintenance. Keep the device clean and free from dust using a dry, soft cloth. Do not use abrasive cleaners or solvents. The internal battery provides a power reserve of 15 days; no user intervention is required for battery maintenance under normal operating conditions.

Troubleshooting

  • Display is blank:
    • Check if the main power supply (230V~) is connected and active.
    • Ensure terminals 5 (L) and 10 (N) are correctly wired.
  • Program not executing:
    • Verify that the current time is set correctly.
    • Check if the program ON/OFF times are correctly entered and confirmed.
    • Ensure the timer is not in permanent manual override mode.
    • Confirm the load is correctly wired to the relay contacts (1, 2, 3).
  • Incorrect time displayed:
    • Reset the current time as per the 'Setting the Current Time' section.

Specifications

BrandPerry
Model Number1IO6080
ColorWhite
Number of Settings3 (Implied by feature bullets, likely referring to programming modes or features)
GTIN08019108031375
Number of Units1
Minimum Programming1 second
Power Reserve15 days
Display2 DIN with backlighting

Support

For further assistance, technical support, or warranty information, please refer to the manufacturer's official website or contact their customer service department. Keep your purchase receipt as proof of purchase.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.