ENM T50A2

ENM T50A2 Quartz Hour Meter Instruction Manual

Model: T50A2 | Brand: ENM

1. Introduction

This manual provides comprehensive instructions for the installation, operation, and maintenance of the ENM T50A2 Quartz Hour Meter. This device is designed to accurately record operating hours for various industrial and commercial applications. Please read this manual thoroughly before installation and operation to ensure proper function and safety.

2. Safety Information

Always observe the following safety precautions to prevent injury and damage to the meter or connected equipment:

  • Ensure power is disconnected from the circuit before attempting any installation or wiring.
  • Installation should only be performed by qualified personnel.
  • Verify that the supply voltage matches the meter's specifications (115 VAC).
  • Do not expose the meter to excessive moisture, dust, or extreme temperatures.
  • Do not attempt to open or repair the meter. There are no user-serviceable parts inside.

3. Product Overview

The ENM T50A2 is a compact, round, 6-digit quartz hour meter designed for panel mounting. It provides a clear, continuous display of accumulated operating hours.

Front view of the ENM T50A2 Quartz Hour Meter

Figure 3.1: Front view of the ENM T50A2 Quartz Hour Meter, showing the ENM logo, 6-digit display, 'HOURS' indicator, and 'QUARTZ CHICAGO' text.

Rear view of the ENM T50A2 Quartz Hour Meter with wiring label

Figure 3.2: Rear view of the ENM T50A2 Quartz Hour Meter, displaying the electrical connection terminals and a label with model number T50A2, 115V 50/60HZ, 5W, and regulatory marks.

4. Setup and Installation

Follow these steps for proper installation of your hour meter:

  1. Panel Mounting: Create a suitable round cutout in your equipment panel according to the meter's dimensions. The meter is designed for a 2.31-inch round opening. Secure the meter using the provided mounting hardware (if applicable) or by its integrated mounting clips.
  2. Wiring: Refer to Figure 3.2 for the terminal connections. The ENM T50A2 is designed for 115 VAC, 50/60 Hz power. Connect the 115 VAC power supply to the two spade terminals on the rear of the meter. Ensure connections are secure and insulated.
  3. Power On: Once wiring is complete and verified, restore power to the circuit. The meter should begin accumulating hours when power is applied.

5. Operating Instructions

The ENM T50A2 Quartz Hour Meter operates automatically. When power is supplied to the meter, it will continuously accumulate operating hours. The 6-digit display shows the total accumulated hours. The last digit (typically red or a different color) represents tenths of an hour.

  • Reading the Display: Read the digits from left to right. For example, '00000.0' indicates zero hours and zero tenths. '00123.4' indicates 123.4 hours.
  • The meter does not have a reset function. It provides a continuous, non-resettable record of operating time.

6. Maintenance

The ENM T50A2 Quartz Hour Meter requires minimal maintenance.

  • Cleaning: If the display or casing becomes dirty, gently wipe it with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Inspection: Periodically check the wiring connections for tightness and signs of wear or corrosion.
  • The meter is a sealed unit and contains no user-serviceable parts. Any attempt to open the unit will void the warranty.

7. Troubleshooting

If you encounter issues with your ENM T50A2 Hour Meter, consider the following troubleshooting steps:

  • Meter Not Counting:
    • Verify that the 115 VAC power supply is active and correctly connected to the meter terminals.
    • Check for loose or corroded wiring connections.
    • Ensure the supply voltage is within the specified range (115 VAC).
  • Display Not Visible/Blank:
    • Confirm power is supplied to the meter.
    • If power is present and connections are secure, the meter may be faulty and require replacement.

If these steps do not resolve the issue, contact ENM customer support for further assistance.

8. Specifications

Model NumberT50A2
TypeQuartz Hour Meter
Voltage Supply115 VAC, 50/60 Hz
Power Consumption5W
Display6 Digit (00000.0)
MountingPanel Mount, 2.31 inch round
Dimensions (W x H x D)1.68" x 1.68" x 1.26"
MaterialQuartz (internal mechanism)
Operating TemperatureRefer to manufacturer's datasheet for specific range.

9. Warranty and Support

ENM products are manufactured to high-quality standards. For specific warranty information, please refer to the official ENM Company warranty policy available on their website or contact their customer service department.

For technical support, replacement parts, or further inquiries, please contact ENM Company directly. Contact details can typically be found on the manufacturer's official website.