1. Introduction
This manual provides essential instructions for the safe and effective use, installation, and maintenance of your SigmasTek CFR-12V100 12 Volt 100 AmpH Sealed Lead Acid (SLA) Replacement Battery. This battery is designed for various applications including Uninterruptible Power Supplies (UPS), emergency lighting, security systems, fire and burglar alarms, scooters, wheelchairs, and medical devices.
Please read this manual thoroughly before using the battery to ensure proper operation and to prevent damage or injury.
2. Safety Information
WARNING: Improper handling of batteries can lead to serious injury or damage. Always follow these safety guidelines.
- Eye Protection: Always wear appropriate eye protection when handling batteries.
- Ventilation: Ensure adequate ventilation when charging or operating batteries to prevent the accumulation of explosive gases.
- Short Circuits: Avoid short-circuiting the battery terminals. This can cause severe burns, fire, or explosion. Do not place tools or metallic objects on top of the battery.
- Handling: Batteries are heavy. Use proper lifting techniques or assistance to prevent injury.
- Charging: Use only chargers specifically designed for 12V SLA batteries. Overcharging can damage the battery and pose a safety risk.
- Disposal: Do not dispose of batteries in fire. Batteries contain lead and sulfuric acid and must be recycled or disposed of according to local regulations.
- Children: Keep batteries out of reach of children.
3. Setup
3.1 Unpacking and Inspection
Carefully remove the battery from its packaging. Inspect the battery for any signs of physical damage, such as cracks, leaks, or deformed terminals. If any damage is observed, do not attempt to use the battery and contact your supplier immediately.
3.2 Terminal Connection
The CFR-12V100 battery is equipped with NB terminals. Ensure that the connecting cables from your device are compatible with NB terminals. Connect the positive (+) terminal of the battery to the positive (+) cable of your device, and the negative (-) terminal of the battery to the negative (-) cable of your device.
Important: Ensure connections are tight and secure to prevent arcing and poor performance. Do not overtighten.

Figure 1: SigmasTek CFR-12V100 12 Volt 100 AmpH SLA Replacement Battery. This image shows the battery with its NB terminals, ready for connection.
3.3 Initial Charge
While SLA batteries are typically shipped in a charged state, it is recommended to fully charge the battery before its first use, especially if it has been stored for an extended period. Refer to your device's manual for specific charging instructions or use a compatible 12V SLA battery charger.
4. Operating Instructions
Once properly installed and charged, the SigmasTek CFR-12V100 battery will provide reliable power to your compatible device. Follow the operating instructions provided with your specific equipment (e.g., UPS, scooter, alarm system) for optimal performance.
- Charging: Always use a charger designed for 12V SLA batteries. Avoid using automotive chargers unless they are specifically designed for deep cycle SLA batteries.
- Discharge: Avoid deep discharging the battery below its recommended voltage levels, as this can significantly reduce its lifespan.
- Temperature: Operate the battery within its specified temperature range (typically 20°C to 25°C or 68°F to 77°F for optimal performance). Extreme temperatures can affect battery capacity and lifespan.
5. Maintenance
Proper maintenance will extend the life and performance of your SigmasTek CFR-12V100 battery.
- Regular Inspection: Periodically check the battery for any signs of damage, corrosion on terminals, or swelling of the casing.
- Cleaning Terminals: If corrosion is present on the terminals, disconnect the battery and clean the terminals with a wire brush and a solution of baking soda and water. Rinse with clean water and dry thoroughly before reconnecting.
- Recharging: If the battery is not in constant use, recharge it every 3-6 months to prevent self-discharge and maintain its capacity.
- Storage: Store the battery in a cool, dry, and well-ventilated area, away from direct sunlight and heat sources. Ensure the battery is fully charged before long-term storage.
6. Troubleshooting
If you encounter issues with your battery, consider the following common troubleshooting steps:
- Battery Not Holding Charge:
- Verify that the charger is functioning correctly and is compatible with 12V SLA batteries.
- Check for loose or corroded terminal connections.
- Ensure the battery has not been subjected to deep discharge for extended periods.
- Consider the age of the battery; SLA batteries have a finite lifespan.
- Device Not Powering On:
- Confirm the battery is fully charged.
- Check all connections between the battery and the device.
- Ensure the device itself is functioning correctly and is compatible with a 12V power source.
- Battery Overheating During Charge:
- Immediately disconnect the charger.
- Ensure adequate ventilation around the battery.
- Verify the charger's voltage and current output are correct for a 12V 100Ah SLA battery.
- If overheating persists, the battery or charger may be faulty.
If these steps do not resolve the issue, contact customer support for further assistance.
7. Specifications
| Feature | Specification |
|---|---|
| Model Number | CFR-12V100 |
| Voltage | 12 Volts |
| Capacity | 100 AmpH |
| Terminal Type | NB Terminal |
| Product Dimensions (L x W x H) | 12 x 6.6 x 8.15 inches |
| Item Weight | 68 pounds |
| Manufacturer | SigmasTek |
| UPC | 609201103871 |