Anyray H&PC-47802

Anyray 9 Watt UV Replacement Bulb Instruction Manual

Model: H&PC-47802

Product Overview

This manual provides instructions for the Anyray 9 Watt UV Replacement Bulb, designed for use in various UV sterilizer units. This bulb emits UV-C germicidal ultraviolet radiation, effective for water purification and air cleaning applications.

  • 9 Watt UV-C Germicidal Ultraviolet Replacement Bulb
  • G23 base
  • 100% Ozone Free Short-wave UV radiation with a peak at 253.7 nm (UVC)
  • Compatible with CF-400UV, CF-500UV, UVP-9, UVCP-9, UVFK-9 units.
  • EPA Est.No.100578-WA-1
Anyray 9 Watt UV Replacement Bulb

Image description: A clear, straight-on view of the Anyray 9 Watt UV replacement bulb. The bulb features two parallel glass tubes connected at the top, with a white plastic G23 base at the bottom. The base has two metal pins for electrical connection and is labeled "EPA Est.#100578-WA-1".

Safety Information

Important Safety Precautions

  • UV Radiation Hazard: Do not look directly at the illuminated UV bulb. UV-C light can cause severe eye and skin damage.
  • Disconnect Power: Always disconnect power to the UV unit before installing, removing, or performing any maintenance on the bulb.
  • Handle with Care: UV bulbs are made of glass and can break easily. Handle the bulb by its base, avoiding contact with the glass surface to prevent oil residue from affecting performance.
  • Proper Disposal: Dispose of old UV bulbs according to local regulations, as they may contain mercury.
  • Intended Use: Use this bulb only in compatible UV sterilizer units as specified.

Installation (Replacement)

This section outlines the general procedure for replacing the UV bulb. Specific steps may vary depending on your UV unit model. Always refer to your unit's original instruction manual for detailed instructions.

Replacing the UV Bulb

  1. Step 1: Disconnect Power. Ensure the UV unit is completely unplugged from the power source.
  2. Step 2: Access the Bulb Housing. Carefully open or remove the cover of your UV unit to access the bulb housing. For some units, like the CF-400UV, this may involve removing the canister filter top.
  3. Step 3: Locate Fasteners. Identify any screws or clips securing the bulb or its protective casing. For units like the CF-400UV, look for two small screws near the base of the bulb.
  4. Step 4: Remove Protective Casing (if applicable). If present, gently remove the glass case or protective sleeve surrounding the bulb.
  5. Step 5: Remove Old Bulb. Grasp the base of the old bulb and gently pull it straight out from its socket. Avoid twisting if possible, as this can damage the pins or socket.
  6. Step 6: Insert New Bulb. Align the pins of the new Anyray 9 Watt UV Replacement Bulb with the slots in the socket. Gently push the bulb straight into the socket until it is firmly seated. Do not force it.
  7. Step 7: Reassemble. Replace the protective casing and secure any screws or clips removed in previous steps. Ensure all components are properly seated and tightened.
  8. Step 8: Close Unit. Close the UV unit cover or reassemble the canister filter top.
  9. Step 9: Reconnect Power. Plug the UV unit back into the power source.
  10. Step 10: Verify Operation. Observe the unit to ensure the new bulb is functioning correctly. Many UV units have an indicator light.

Operation

Bulb Function

The Anyray 9 Watt UV Replacement Bulb emits germicidal UV-C light. When installed in a compatible UV sterilizer, this light helps to neutralize harmful microorganisms such as bacteria, viruses, and algae by disrupting their DNA, preventing reproduction. This process contributes to clearer water in ponds and aquariums, or improved air quality in air cleaning devices.

The bulb operates continuously when power is supplied to the UV unit.

Maintenance

Recommended Replacement Schedule

To maintain optimal performance and germicidal effectiveness, it is recommended to replace the Anyray 9 Watt UV Replacement Bulb every 6 to 8 months of continuous use. While the bulb may still emit visible light beyond this period, its UV-C output diminishes over time, reducing its sterilization capability.

Cleaning

Periodically inspect the quartz sleeve (if your unit has one) that surrounds the UV bulb. If it appears dirty or has mineral deposits, carefully clean it according to your UV unit's instructions to ensure maximum UV light transmission. Always disconnect power before cleaning.

Troubleshooting

Common Issues and Solutions

ProblemPossible CauseSolution
Bulb does not light upNo power to unitCheck power connection and outlet.
Bulb does not light upBulb not properly seatedDisconnect power, remove and reinsert bulb firmly into socket.
Bulb does not light upDefective bulbIf a new bulb, contact seller for replacement. If an old bulb, replace with a new one.
Bulb does not light upFaulty UV unitIf multiple new bulbs fail, the UV unit itself may be faulty. Consult your UV unit's manual or manufacturer.
Reduced effectivenessOld bulbReplace bulb every 6-8 months.
Reduced effectivenessDirty quartz sleeveClean the quartz sleeve according to your UV unit's instructions.

If troubleshooting steps do not resolve the issue, contact the manufacturer or seller for further assistance.

Specifications

Product Specifications

  • Brand: Anyray
  • Model Number: H&PC-47802
  • Wattage: 9 Watts
  • Bulb Base: G23
  • Bulb Shape Size: C9
  • Light Color: Ultraviolet (UV-C)
  • Connectivity Technology: Normal bulb
  • EPA Establishment Number: 100578-WA-1
  • GTIN/UPC: 765573795653

Warranty Information

Warranty

Specific warranty details for the Anyray 9 Watt UV Replacement Bulb are not provided in this manual. For information regarding warranty coverage, terms, and conditions, please refer to the product packaging or contact Anyray customer service directly.

Customer Support

Support

For technical assistance, questions about compatibility, or other inquiries, please contact the seller or Anyray customer support.

Manufacturer: Anyray

Seller: Anyray_Mall (via Amazon)

© 2026 Anyray. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.